Selyan Acid

Selyan Acid

Auto-generated profile, based on publicly available information

Selyan Acid

Centre National dEtudes Spatiales (CNES), Toulouse, France

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SASelyan Acid
Selyan Acid
FFFiammetta Fricano
Fiammetta Fricano
AMAdriana Morana
Adriana Morana
NKNourdine Kerboub
Nourdine Kerboub
AMAubry Marine
Aubry Marine
Sylvain GirardSylvain Girard
Sylvain Girard
Dosimetry holds significant importance across various applications such as radiotherapy, nuclear power plants, accelerators, and space research domains. Indeed, ensuring accurate dosimetry calibration is crucial for radioprotection or operations. In the context of challenging environments such as space, temperature calibration of radiation sensors plays an important role in ensuring their performances. This article discusses the temperature calibration of a cerium (Ce)-doped silica (SiO2)-based Optical Fiber (OF). The calibration covers a temperature range, during 40 keV X-rays irradiation, varying from - 80 °C to +100 °C, meeting the requirements for space applications and allowing for the determination of the temperature dependence of the Radiation Induced Luminescence (RIL). The tests were repeated on three identical 1 cm-long Ce-doped OFs. Our experiments reveal a temperature dependence of the RIL, particularly noticeable at low temperatures, where RIL decreases significantly as the temperature drops. Consequently, a temperature sensitivity curve for RIL is proposed, to calibrate the variations in RIL responses across the investigated temperature range. However, in complex operation conditions, with varying dose rates and temperatures, other phenomena could alter the detector performances, in particular the thermoluminescence observed during strong positive temperature gradients. This work contributes to highlight the potential of RIL-based sensors under varying temperature conditions, crucial for improving the reliability and accuracy, especially in a harsh environment as space.

1 February 2026 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
MRMartin Roche
Martin Roche
AMAdriana Morana
Adriana Morana
SASelyan Acid
Selyan Acid
EMEmmanuel Marin
Emmanuel Marin
ABAziz Boukenter
Aziz Boukenter
Sylvain GirardSylvain Girard
Sylvain Girard

2 March 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SASelyan Acid
Selyan Acid
FFFiammetta Fricano
Fiammetta Fricano
AMAdriana Morana
Adriana Morana
NKNourdine Kerboub
Nourdine Kerboub
AMAubry Marine
Aubry Marine
Sylvain GirardSylvain Girard
Sylvain Girard
This study investigates the impact of pre-irradiation on radiation-induced luminescence (RIL) based optical fiber dosimeters and compares the performances of Copper (Cu)-, Cerium (Ce)- and Cu/Ce-co-doped silica optical fibers under ionizing radiations. A total of 112 optical fiber probes were tested under 40 keV mean energy fluence X-rays over a wide dose rate range (5 mGy/s to 1.5 Gy/s) after different levels of pre-irradiation treatments (up to 2 MGy). Spectral analyses were also conducted to study the impact of total ionizing dose (TID) on spectral emission profiles. Results show that the pre-irradiation improves the RIL linearity with the dose rate, particularly for Cu-doped optical fibers. Cu/Ce-co-doped optical fibers show higher radiation sensitivity but also a greater probe-to-probe dispersion. However, this latter remains below 30% for all the investigated samples. Normalized RIL spectra show that Ce-doped optical fibers maintain a stable emission spectrum with increasing dose, while Cu- and Cu/Ce-co-doped optical fibers show spectral changes, through a blue shift of the RIL peak. These results underline the benefit of pre-irradiating the radioluminescent optical fibers to optimize their RIL dosimetry performances. For the most challenging applications, an individual calibration remains today needed for accurate dosimetry.

1 January 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SAS. Acid
S. Acid
AMAdriana Morana
Adriana Morana
IZI. Zghari
I. Zghari
AMAubry Marine
Aubry Marine
NKN. Kerboub
N. Kerboub
Sylvain GirardSylvain Girard
Sylvain Girard

4 February 2026 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
SASelyan Acid
Selyan Acid
AMAdriana Morana
Adriana Morana
NKNourdine Kerboub
Nourdine Kerboub
AMAubry Marine
Aubry Marine
JMJulien Mekki
Julien Mekki
Sylvain GirardSylvain Girard
Sylvain Girard