17 November 2023 in IEEE Transactions on Instrumentation and Measurement
To address the limitations of typical coil detection systems and enhance the performance of traditional magnetic field imaging (MFI) systems, we propose a MFI system that uses a $4\times4$ array of anisotropic magnetoresistance (AMR) sensors. The core controller of the proposed system was designed using a pipelined parallelization algorithm and implemented on a high-speed field-programmable gate array (FPGA) in a fully hardware-based architecture. The designed MFI system can achieve parallel acquisition of magnetic field components from the 16-channel AMR sensor array, parallel data processing, parallel data transmission, and parallel computations in a single cycle of only 4 ms. Compared with typical detection systems, the proposed solution not only exhibits superior performance but can also provide dynamic visual representations of sensed information.
11 May 2026 in SSRN Electronic Journal
Taiwan imports approximately 97% of its primary energy, while its centralized power grid has experienced repeated large-scale outage events in recent years, exposing the structural vulnerability of single-point-of-failure architectures. This study presents a seven-month empirical evaluation of a self-designed and self-installed residential photovoltaic-battery energy storage system (PV-BESS) deployed on a four-story townhouse in southern Taiwan. The system comprises 3.56 kWp of crystalline silicon modules and a 16.07 kWh lithium iron phosphate (LFP) battery, configured for self-consumption with CT-based anti-backflow control and automatic islanding capability. Monitored from September 2025 through March 2026, the system generated a cumulative 2,276.8 kWh with a daily average of 11.22 kWh. The global-tilted-irradiance-corrected performance ratio averaged 64.2%, consistent with subtropical residential installations. Grid electricity consumption fell by 65.5% compared with the same period before installation, while electricity costs decreased by 89.4%, a disproportionate saving attributable to the progressive tiered tariff structure. The weighted-average self-sufficiency ratio over six months was approximately 58%, and the estimated carbon dioxide reduction was 1,127 kg. Blackout resilience simulations indicate that under a minimum-survival load of 580 W, the battery alone can sustain household operations for approximately 23.6 hours; with favorable solar recharge, the system can exceed the 72-hour preparedness threshold, reaching 7.1 days under optimal conditions. At a self-installation cost of approximately USD 3,800, the simple payback period is estimated at 9.5 years. The implications for resilience-oriented valuation of residential PV-BESS are discussed.