Shuai Dou

Shuai Dou

Auto-generated profile, based on publicly available information

Shuai Dou

Institute of Large-Scale Scientific Facility and the Centre for Zero Magnetic Field Science, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2024 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
YCYimin Chen
Yimin Chen
LXLiu Xikai
Liu Xikai
SDShuai Dou
Shuai Dou
YFYunfei Fang
Yunfei Fang
PSPengfei Song
Pengfei Song
BHBangcheng Han
Bangcheng Han
Ferromagnetic boundary coupling is one key factor that limits the control accuracy of the residual magnetic field in the magnetic shielding room. Usually the image method is utilized to suppress the coupling, but the tolerance for door slit and holes of the image method is poor. Here, we propose the self-shielding method for suppressing the ferromagnetic boundary coupling with higher coupling suppression ability and better tolerance for door slit and holes. Two sets of biplane coils for one axis are designed for achieving uniform magnetic field in the target area and nearzero magnetic field in the shielding area near the passive metal shielding layer simultaneously. We have determined the analysis method and design process of the self-shielding method, and verified its feasibility by experimental test. The proposed method can provide new ideas for improving the control accuracy of the residual magnetic field in the magnetic shielding room, ensuring the smooth progress of magnetoencephalography measurement.

3 January 2024 in Measurement
Verified
Journal Article
Closed access
YLYanbin Li
Yanbin Li
SDShuai Dou
Shuai Dou
LXLiu Xikai
Liu Xikai
PCPeiling Cui
Peiling Cui
ZYZhouqiang Yang
Zhouqiang Yang
TWTong Wen
Tong Wen

14 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SDShuai Dou
Shuai Dou
LXLiu Xikai
Liu Xikai
SSShengyi Shangguan
Shengyi Shangguan
Wen TongWen Tong
Wen Tong
SZShiqiang Zheng
Shiqiang Zheng
BHBangcheng Han
Bangcheng Han
The biplane coils (BCs) based on the inverse-design method are crucial for creating the near-zero magnetic environment in magnetic shielding room (MSR), but multi-parameters optimization remains a key factor that limits the performance of the BCs. This study proposes a funnel algorithm (FA) to solve the issue of multi-parameter optimization in the design. The upper and lower limits of the parameters are dynamically adjusted based on the previous calculating step. By gradually reducing the upper and lower limits, we achieve the BCs with optimal performance. This method has been verified by both the theoretical analysis and experimental test. Compared with other methods, the designed coils show a higher space utilization ratio (SUR) and smaller relative errors, with the SUR improved from 1.6% to 3.75% and the relative errors all less than 2%. Based on the designed BCs, the total residual magnetic field is stabilized below 40.4 pT at the central point of the MSR, with the noise reaching the intrinsic noise of the flux-gate magnetometer in the frequency range of interest. The proposed method can significantly improve the performance of the BCs, thus reducing the space and construct cost of the MSR and promoting the magnetoencephalogram (MEG) measurement based on the quantum technology.

5 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XZXiuqi Zhao
Xiuqi Zhao
LZLu Zhang
Lu Zhang
Xu ZhangXu Zhang
Xu Zhang
SDShuai Dou
Shuai Dou
Jianzhi YangJianzhi Yang
Jianzhi Yang
SZShiqiang Zheng
Shiqiang Zheng
Low-frequency excitation magnetic field coils are potent tools for studying the effects of magnetic fields on cells. However, the existing excitation magnetic field coils are vulnerable to external magnetic fields and difficult to generate a high uniform excitation magnetic field with a small size. Thus, this study proposes a novel optimization design method combining the target field method (TFM), thickness mirror image method, and fruit fly optimization algorithm (FOA) to design a new type of bi-planar excitation magnetic field coil placed in a near-zero magnetic cell incubator. Based on the optimization design method, three bi-planar coils of Bx , By and Bz with the paralleled arrangement in a near-zero magnetic cell incubator with the size of 365 mm × 336 mm × 200 mm were designed and measured. The coil constants of Bx ( By ) and Bz are 8860 nT/A and 100640 nT/A, respectively. The non-uniformity of the Bx ( By ) and Bz coils are less than 5% and 1% over the central volume of 80 × 80 × 80 mm 3 , 100 × 100 × 100 mm 3 , respectively, meeting the most requirement of working space and the amplitude of magnetic field for cell research.

19 September 2024 in NeuroImage
Verified
Journal Article
Open access
SDShuai Dou
Shuai Dou
LXLiu Xikai
Liu Xikai
YDYa Deng
Ya Deng
YCYimin Chen
Yimin Chen
PSPengfei Song
Pengfei Song
BHBangcheng Han
Bangcheng Han
Magnetoencephalography based on optically pumped magnetometers can passively detect the ultra-weak brain magnetic field signals, which has significant clinical application prospects for the diagnosis and treatment of cerebral disorders. This paper proposes a brain magnetic signal measurement method on the basis of the active-passive coupling magnetic shielding strategy and helmet-mounted detection array, which has lower cost and comparable performance over the existing ones. We first utilized the spatially-grid constrained coils and biplanar coils with proportion-integration-differentiation controller with tracking differentiator to ensure a near-zero and stable magnetic field environment with large uniform region. Subsequently, we implemented the brain magnetic signal measurement with the subject randomly moving fingers through tapping a keyboard and with the condition of opening and closing the eyes. Effectively induced brain magnetic signals were detected at the motor functional area and occipital lobe area in the two experiments, respectively. The proposed method will contribute to the development of functional brain imaging.

1 July 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
SDShuai Dou
Shuai Dou
LXLiu Xikai
Liu Xikai
PSPengfei Song
Pengfei Song
YCYidi Cao
Yidi Cao
Wen TongWen Tong
Wen Tong
BHBangcheng Han
Bangcheng Han
Magnetocardiography (MCG) enables passive detection of weak magnetic fields generated by the heart with high sensitivity, which can offer valuable information for diagnosing and treating heart conditions. Due to the limitations of the geomagnetic field and unknown magnetic interference, the MCG signals are often overwhelmed by high levels of magnetic noise. In this paper, we propose the design of a high-resolution and movable MCG system comprised of an active-passive coupling magnetic control (AP-CMC) system and a wearable multi-channel signal detection array. The system realizes the MCG measurement at the same time as the AP-CMC system eliminates interference in real time, i.e., simultaneous control and simultaneous measurement. Dynamic MCG signal measurements were successfully conducted, obtaining typical characteristic features of MCG signals. Our method shows promise in enhancing the accuracy and expanding the scope of MCG measurement applications, thereby offering valuable insights for the early diagnosis and precise localization of heart diseases.