Tianjin Key Laboratory of Optoelectronic Detection Technology and Systems, School of Electronics and Information Engineering, Tiangong University, Tianjin, China
Auto-generated profile, based on publicly available information
Fanglin Xie
Tianjin Key Laboratory of Optoelectronic Detection Technology and Systems, School of Electronics and Information Engineering, Tiangong University, Tianjin, China
Human body temperature is an important indicator of physical health. Waveguide Bragg grating (WBG)- and microring resonator (MRR)-based polymer optical waveguide temperature sensors provide alternative methods for monitoring the human body temperature. In this study, optical waveguide temperature sensors, with a combination of polymethylmethacrylate (PMMA) and polydimethylsiloxane (PDMS) for the formation of waveguide structures, are designed and fabricated via a polymer-based fabrication process to achieve real-time temperature measurements in situ. We experimentally characterized and compared the sensor thermal properties within the temperature range of 35–40 °C. Based on the results from our study, the WBG and MRR temperature sensors had high sensitivity properties. The temperature sensitivity coefficient of the WBG temperature sensor was -177.6 pm/°C, and that of the MRR temperature sensor was -0.03035 mW/°C. The error of these two temperature sensors did not exceed 0.1 °C. These sensors show great promise as basic sensing elements in optical waveguide sensor applications for the early detection and monitoring of heat-related illnesses.
20 March 2025 in IEEE Transactions on Instrumentation and Measurement
Traditional electrical pressure sensors are prone to electromagnetic interference; however, the emergence of optical pressure sensors offers a novel means of fabricating flexible devices. A pressure sensor based on a polymer optical waveguide is presented in this article that incorporates three cascaded microring resonators (MRRs) for enhanced sensitivity and accuracy. The sensor was fabricated from a polymer with a low Young’s modulus to achieve flexibility and enhanced sensitivity. The wavelength change in the output spectrum of the sensor was utilized to precisely measure the pressure applied to the device, and the structural parameters and the cascaded array of MRRs were optimized to improve the sensitivity of the pressure sensor. The experimental results show that the sensor has a sensitivity of 21.86 pm/kPa within the pressure range of 0–20 kPa with an accuracy of 1 kPa. The proposed MRR array pressure sensor exhibits high sensitivity and excellent linearity, and can be easily integrated into a device, indicating considerable application potential for wearable optical sensing.
Silicon photonic biosensors can be fabricated via standard CMOS microfabrication techniques, with many sensing sites integrated on the same chip. In this work, we report the design and validation of a cascaded 1 × 4 racetrack-shaped microring resonator (rsMRR) based on silicon-on-insulator (SOI), optimizing key parameters, such as the waveguide width, coupling gap, and ring radius. Moreover, we comprehensively characterize the sensing performance of the rsMRR. The experimental results show that the resonator achieves a sensitivity of 117 nm/RIU within a glucose concentration range of 03.3 mg/mL. Compared with traditional structures, this design reduces optical loss through its racetrack-shaped layout, reaching a quality factor (Q-factor) of 510, and has advantages such as high integration density, anti-interference capability, and miniaturization. This work reveals the potential of silicon-based rsMRRs for practical glucose-sensing applications.