22 July 2021 in ACS Biomaterials Science & Engineering
AMAna Elisa Dotta Maddalozzo
Ana Elisa Dotta Maddalozzo
+5
1 January 2021 in Materials Research
CGCharlene Silvestrin Celi Garcia
Charlene Silvestrin Celi Garcia
AMAna Elisa Dotta Maddalozzo
Ana Elisa Dotta Maddalozzo
PGPaulo Miguel Celi Garcia
+4
13 October 2020 in Materials Advances
EBEstela K. Kerstner Baldin
Estela K. Kerstner Baldin
RBRodrigo Antônio Barbieri
+4
The sterilization process is essential for the use of biomaterials in the human body in order to avoid contamination. However, the effect of such required pretreatment on the surface must be also evaluated since some modifications may cause a shortened lifespan of this material or changes in properties of interest. Moreover, improvements in sterilization techniques may even enhance properties while the surface is cleaned. The thorough understanding of the effect that the sterilization processes have on the surface of ultra-high molecular weight polyethylene (UHMWPE), widely used biomaterial in orthopedic joint prosthesis, is, therefore, a key study since some modifications during traditional sterilization could be a major problem for patients who have undergone arthroplasty surgery. This work brings a comprehensive study on sterilization techniques already available and extensively used (hydrogen peroxide plasma, ethylene oxide, steam autoclave) and a comparison with results obtained for recently developed cold plasma-based sterilization technique. The effects of the processes have been extensively compiled by data obtained for thermal analysis, nanoscale wear and friction, physicochemical, topographical, wettability, and in vitro cytotoxicity experiments. An overall outlook on the set of samples points out to cold plasma oxidation (CPO) being an adequate and potential candidate for improving wear resistance, while maintaining thermal stability and a restrained adhesion of L929 cells, provoked by its hydrophilicity and larger surface area.
21 May 2021 in Journal of Materials Engineering and Performance
CFCristian Padilha Fontoura
Cristian Padilha Fontoura
AMAna Elisa Dotta Maddalozzo
Ana Elisa Dotta Maddalozzo
JCJanaina da Silva Crespo
+1
24 November 2020 in Materials Advances
EBEstela K. Kerstner Baldin
Estela K. Kerstner Baldin
LLLeonardo Mathias Leidens
RBRodrigo Antônio Barbieri
+4
Correction for ‘Overview of sterilization methods for UHMWPE through surface analysis’ by Melissa Machado Rodrigues et al., Mater. Adv., 2020, DOI: 10.1039/d0ma00772b.
22 July 2025 in ACS Omega
EBEstela K. Kerstner Baldin
Estela K. Kerstner Baldin
AMAna Elisa Dotta Maddalozzo
Ana Elisa Dotta Maddalozzo
+6
Surface modification of implant materials continues to address the issue of osseointegration. Moreover, combining osseointegration with bactericidal or antifouling properties in implants remains an open question for debate. Over the years, silver has been widely used as an agent for killing and preventing bacterial proliferation. Silicon, on the other hand, has been linked to improved osteogenic activity. In this work, titanium plates were incorporated with both Ag and Si ions through low-energy ion implantation, and surface characterization was carried out to validate the process. Ti plates containing 43 μg cm–2 Ag were further enriched with small amounts of Si, as verified by glow discharge optical emission spectroscopy (GD-OES) and energy-dispersive X-ray spectroscopy (EDS). This added step increased surface roughness by approximately 11% and led to a statistically significant difference in wettability, rendering hydrophilic features (from angles around 90° to below 70° for the Ag + Si condition)both of which influence biocompatibility. Electrochemical tests showed a more reactive surface for implanted samples but nonetheless demonstrated stability over 28 days. Further research should focus on increasing the Si doping in Ti and evaluating subsequent in vitro conditions.