The design, fabrication, and characterization of a new type of tactile display for people with blindness or low vision is reported. Each tactile element comprises a piezoelectric extensional actuator that vibrates in plane, with a microfabricated scissor mechanism to convert the in-plane actuations into robust, higher-amplitude, out-of-plane (vertical) vibrations that are sensed with the finger pads. When the tactile elements are formed into a 2D array, information can be conveyed to the user by varying the pattern of vibrations in space and time. Analytical models and finite element analysis were used to design individual tactile elements, which were implemented with PZT actuators and both SU-8 and 3D-printed scissor amplifiers. The measured displacements of these 3 mm × 10 mm, MEMS-enabled tactile elements exceed 10 µm, in agreement with models, with measured forces exceeding 45 mN. The performance of the MEMS-enabled tactile elements is compared with the performance of larger, fully-macroscale tactile elements to demonstrate the scale dependence of the devices. The creation of a 28-element prototype is also reported, and the qualitative user experience with the individual tactile elements and displays is described.
10 December 2015 in Journal of Physics: Conference Series
The design, fabrication, and demonstration of a set of 2 mm2, high-force actuators that combine piezoelectric in-plane actuators with MEMS-enabled scissor mechanisms (motion amplifiers) to simultaneously produce high out-of-plane forces and large out-of-plane displacements are presented. The microscissor motion amplifier employs two layers of lithographically-patterned SU-8 microstructure laminated with a thin film of structural polyimide and adhesive to form hinges. Performance is optimized by varying layer thickness and adhesive types. Measured displacements of >3 μm and measured forces of >5 mN are observed, corresponding to a displacement per unit area of 1.6 μm/mm2 and a force per unit area of 2.6 mN/mm2. Cyanoacrylate adhesive provides superior performance to silicone adhesive, with larger force output. Thicker polyimide hinges provide smaller displacement but greater force than thinner polyimide hinges. These powerful, compact actuators have significant potential for high-force applications like tactile displays and micropumps.