Thomas J. Forbes

Thomas J. Forbes

Auto-generated profile, based on publicly available information

Thomas J. Forbes

Children’s Hospital of Michigan, Wayne State University

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2007 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
TFThomas J. Forbes
Thomas J. Forbes
SGSwati Garekar
Swati Garekar
ZAZahid Amin
Zahid Amin
EZEvan M. Zahn
Evan M. Zahn
DNDavid Nykanen
David Nykanen
WHWilliam E. Hellenbrand
William E. Hellenbrand

26 September 2007 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
TFThomas J. Forbes
Thomas J. Forbes
PMPhillip Moore
Phillip Moore
CPCarlos A.C. Pedra
Carlos A.C. Pedra
EZEvan M. Zahn
Evan M. Zahn
DNDavid Nykanen
David Nykanen
WHWilliam E. Hellenbrand
William E. Hellenbrand

4 January 2011 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
TFThomas J. Forbes
Thomas J. Forbes
ZHZiyad M. Hijazi
Ziyad M. Hijazi
GYGuy Young
Guy Young
JRJeremy M Ringewald
Jeremy M Ringewald
PAPaolo M. Aquino
Paolo M. Aquino
RZRolando Zamora
Rolando Zamora

17 December 2009 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
AGAbdolrahim Ghasemi
Abdolrahim Ghasemi
SPSwati Pandya
Swati Pandya
SRSurendranath Reddy Veeram Reddy
Surendranath Reddy Veeram Reddy
DTDaniel R. Turner
Daniel R. Turner
WDWei Du
Wei Du
TFThomas J. Forbes
Thomas J. Forbes

18 June 2003 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
TFThomas J. Forbes
Thomas J. Forbes
EREdwin Rodriguez‐Cruz
Edwin Rodriguez‐Cruz
ZAZahid Amin
Zahid Amin
LBLee N. Benson
Lee N. Benson
TFThomas E. Fagan
Thomas E. Fagan
JVJulie A. Vincent
Julie A. Vincent

18 March 2025 in Circulation
Verified
Journal Article
Open access
EREric Rosenthal
Eric Rosenthal
SQShakeel A. Qureshi
Shakeel A. Qureshi
KSKothandam Sivakumar
Kothandam Sivakumar
MJMatthew Jones
Matthew Jones
SYSan-Fui Yong
San-Fui Yong
EZEvan M. Zahn
Evan M. Zahn
BACKGROUND: Covered stent correction for a sinus venosus atrial septal defect (SVASD) was first performed in 2009. This innovative approach was initially viewed as experimental and was reserved for highly selected patients with unusual anatomic variants. In 2016, increasing numbers of procedures began to be performed, and in several centers, it is now offered as a standard of care option alongside surgical repair. However, covered stent correction for SVASD is not recognized by regulatory authorities, and in the minds of many pediatric and adult congenital cardiologists and surgeons, the condition is viewed as treatable only by cardiac surgery with cardiopulmonary bypass. METHODS: In April 2023, all centers identified from international conferences, publications, and colleague networks to be undertaking covered stent correction for SVASD were invited to participate in a retrospective audit of their procedures. RESULTS: Data were received on 381 patients from 54 units over a 12-year period with 90% of procedures being performed over the past 5 years. Balloon-expandable stents (8 types) were used in the majority; self-expanding stents (4 types) were used in 4.5%. The commonest stent was the 10-zig covered Cheatham Platinum stent in 62% of cases. In 10 procedures, the stent embolized requiring surgical retrieval and repair of the defect, resulting in technically successful implantation in 371 of 381 (97.4%). Major complications (surgical drainage of tamponade, pacemaker implantation, surgery for pulmonary vein occlusion, and late stent removal) occurred in 5 patients (1.3%). Repeat catheterization to correct residual leaks was required in 7 patients (1.8%). Thus, 359 of 381 patients (94.2%) had successful correction without major complications or additional catheter interventions. CONCLUSIONS: This article details the exponential uptake of covered stent correction for SVASD during the past 5 years. Cardiopulmonary bypass was avoided in the majority of patients, and major complications were infrequent. Prospective registries with standardized definitions, inclusion criteria, and follow-up and comparative studies with surgery are now required to help support the extension of covered stent correction as an alternative standard-of-care option for patients with an SVASD.