Jiwoong Kim

Jiwoong Kim

Auto-generated profile, based on publicly available information

Jiwoong Kim

Departments of Convergence IT Engineering, Electrical Engineering, Mechanical Engineering, and Medical Science and Engineering, POSTECH-CATHOLIC Biomedical Engineering Institute, Medical Device Innovation Center, Pohang University of Science and Technology, Pohang, Republic of Korea

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2024 in ACS Nano
Verified
Journal Article
Open access
JKJiwoong Kim
Jiwoong Kim
JLJihye Lee
Jihye Lee
Seongwook ChoiSeongwook Choi
Seongwook Choi
HLHyori Lee
Hyori Lee
JYJinge Yang
Jinge Yang
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
Photoacoustic computed tomography (PACT), an emerging imaging modality in preclinical cancer research, can provide multiparametric 3D information about structures, physiological functions, and pharmacokinetics. Here, we demonstrate the use of high-definition 3D multiparametric PACT imaging of both primary and metastatic tumors in living mice to noninvasively monitor angiogenesis, carcinogenesis, hypoxia, and pharmacokinetics. The high-definition PACT system with a 1024-element hemispherical ultrasound transducer array provides an isotropic spatial resolution of 380 μm, an effective volumetric field-of-view of 12.8 mm × 12.8 mm × 12.8 mm without scanning, and an acquisition time of <30 s for a whole mouse body. Initially, we monitor the structural progression of the tumor microenvironment (e.g., angiogenesis and vessel tortuosity) after tumor cell inoculation. Then, we analyze the change in oxygen saturation of the tumor during carcinogenesis, verifying induced hypoxia in the tumor's core region. Finally, the whole-body pharmacokinetics are photoacoustically imaged after intravenous injection of micelle-loaded IR780 dye, and the in vivo PACT results are validated in vivo and ex vivo by fluorescence imaging. By employing the premium PACT system and applying multiparametric analyses to subcutaneous primary tumors and metastatic liver tumors, we demonstrate that this PACT system can provide multiparametric analyses for comprehensive cancer research.

4 December 2024 in Advanced Science
Verified
Journal Article
Open access
JKJiwoong Kim
Jiwoong Kim
JKJoo Young Kweon
Joo Young Kweon
Seongwook ChoiSeongwook Choi
Seongwook Choi
HJHyunseo Jeon
Hyunseo Jeon
MSMinsik Sung
Minsik Sung
YAYong Joo Ahn
Yong Joo Ahn
Early‐stage stroke monitoring enables timely intervention that is crucial to minimizing neuronal damage and increasing the extent of recovery. By monitoring collateral circulation and neovascularization after ischemic stroke, the natural recovery process can be better understood, optimize further treatment strategies, and improve the prognosis. Photoacoustic computed tomography (PACT), a non‐invasive imaging modality that captures multiparametric high‐resolution images of vessel structures, is well suited for evaluating cerebrovascular structures and their function. Here 3D multiparametric transcranial PACT is implemented to monitor the early stage of a photothrombotic (PT)‐stroke model in living rats. New vessels in the PT‐induced region are successfully observed using PACT, and these observations are confirmed by histology. Then, using multiparametric PACT, it is found that the SO2 in the ischemic area decreases while the SO2 in newly formed vessels increases, and the SO2 in the PT region also recovers. These findings demonstrate PACT's remarkable ability to image and monitor cerebrovascular morphologic and physiological changes. They highlight the usefulness of whole‐brain PACT as a potentially powerful tool for early diagnosis and therapeutic decision‐making in treating ischemic stroke.

22 May 2025 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
ELEun Sook Lee
Eun Sook Lee
JLJinhyung Lee
Jinhyung Lee
JKJiwoong Kim
Jiwoong Kim
JKJueun Kim
Jueun Kim
JWJungsub Wi
Jungsub Wi
HNHee-Kyung Na
Hee-Kyung Na

30 January 2026 in Science Advances
Verified
Journal Article
Open access
DLDonghyun Lee
Donghyun Lee
JKJiwoong Kim
Jiwoong Kim
JHJinseok Heo
Jinseok Heo
HJHyunseo Jeon
Hyunseo Jeon
SCShiyang Chang
Shiyang Chang
YZyang zhifen
yang zhifen
The placenta is a pregnancy-specific organ, functioning as the maternal-fetal interface and mediating essential processes including exchange, protection, and endocrine regulation. Placental abnormalities contribute to the pathophysiology, onset, progression, and prognosis of major perinatal disorders, making imaging modalities that enable their detection and monitoring crucial. Ultrasound (US) imaging is the principal modality for placental imaging, providing structural assessment with B-mode and blood flow evaluation with Doppler mode. Furthermore, advanced techniques such as 3D power Doppler, quantitative US, and shear-wave elastography expand the capabilities of placental US imaging. Photoacoustic (PA) imaging enables observation of the optical properties of endogenous chromophores (e.g., hemoglobin) with high spatial resolution and measures blood oxygenation, a key factor in placental dysfunction, offering substantial value for placental imaging. In this review, we cover US/PA imaging techniques for placental imaging, including preclinical and clinical studies. In addition, by considering current limitations and potential solutions, we suggest future trajectories for the advancement of US/PA imaging in this field.