Seongwook Choi

Dr. Seongwook Choi

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2024 in Nature Reviews Bioengineering
Verified
Journal Article
Closed access
PDF file
JPJeongwoo Park
Jeongwoo Park
Seongwook ChoiSeongwook Choi
Seongwook Choi
FKFerdinand Knieling
Ferdinand Knieling
BCBryan Clingman
Bryan Clingman
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim

16 January 2023 in Chemical Reviews
Verified
Journal Article
Closed access
WCWonseok Choi
Wonseok Choi
BPByullee Park
Byullee Park
Seongwook ChoiSeongwook Choi
Seongwook Choi
DODonghyeon Oh
Donghyeon Oh
JKJongbeom Kim
Jongbeom Kim
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim

30 August 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
JBJin Woo Baik
Jin Woo Baik
JKJin Young Kim
Jin Young Kim
SCSeonghee Cho
Seonghee Cho
Seongwook ChoiSeongwook Choi
Seongwook Choi
JKJongbeom Kim
Jongbeom Kim
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
Acoustic-resolution photoacoustic microscopy (AR-PAM) is an emerging biomedical imaging modality that combines superior optical sensitivity and fine ultrasonic resolution in an optical quasi-diffusive regime (∼1-3 mm in tissues). AR-PAM has been explored for anatomical, functional, and molecular information in biological tissues. Heretofore, AR-PAM systems have suffered from a limited field-of-view (FOV) and/or slow imaging speed, which have precluded them from routine preclinical and clinical applications. Here, we demonstrate an advanced AR-PAM system that overcomes both limitations of previous AR-PAM systems. The new AR-PAM system demonstrates a super wide-field scanning that utilized a 1-axis water-proofing microelectromechanical systems (MEMS) scanner integrated with two linear stepper motor stages. We achieved an extended FOV of 36 × 80mm2 by mosaicking multiple volumetric images of 36 × 2.5 mm2 with a total acquisition time of 224 seconds. For one volumetric data (i.e., 36 × 2.5 mm2), the B-scan imaging speed over the short axis (i.e., 2.5 mm) was 83 Hz in humans. The 3D volumetric image was also provided by using MEMS mirror scanning along the X-axis and stepper-motor scanning along the Y-axis. The super-wide FOV mosaic image was realized by registering and merging all individual volumetric images. Finally, we obtained multi-plane whole-body in-vivo PA images of small animals, illustrating distinct multi-layered structures including microvascular networks and internal organs. Importantly, we also visualized microvascular networks in human fingers, palm, and forearm successfully. This advanced MEMS-AR-PAM system could potentially enable hitherto not possible wide preclinical and clinical applications.

10 November 2022 in Advanced Science
Verified
Journal Article
Open access
Seongwook ChoiSeongwook Choi
Seongwook Choi
JYJinge Yang
Jinge Yang
SLSoo Young Lee
Soo Young Lee
JKJiwoong Kim
Jiwoong Kim
JLJihye Lee
Jihye Lee
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
Photoacoustic computed tomography (PACT) has become a premier preclinical and clinical imaging modality. Although PACT's image quality can be dramatically improved with a large number of ultrasound (US) transducer elements and associated multiplexed data acquisition systems, the associated high system cost and/or slow temporal resolution are significant problems. Here, a deep learning‐based approach is demonstrated that qualitatively and quantitively diminishes the limited‐view artifacts that reduce image quality and improves the slow temporal resolution. This deep learning‐enhanced multiparametric dynamic volumetric PACT approach, called DL‐PACT, requires only a clustered subset of many US transducer elements on the conventional multiparametric PACT. Using DL‐PACT, high‐quality static structural and dynamic contrast‐enhanced whole‐body images as well as dynamic functional brain images of live animals and humans are successfully acquired, all in a relatively fast and cost‐effective manner. It is believed that the strategy can significantly advance the use of PACT technology for preclinical and clinical applications such as neurology, cardiology, pharmacology, endocrinology, and oncology.

28 June 2024 in ACS Nano
Verified
Journal Article
Open access
JKJiwoong Kim
Jiwoong Kim
JLJihye Lee
Jihye Lee
Seongwook ChoiSeongwook Choi
Seongwook Choi
HLHyori Lee
Hyori Lee
JYJinge Yang
Jinge Yang
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
Photoacoustic computed tomography (PACT), an emerging imaging modality in preclinical cancer research, can provide multiparametric 3D information about structures, physiological functions, and pharmacokinetics. Here, we demonstrate the use of high-definition 3D multiparametric PACT imaging of both primary and metastatic tumors in living mice to noninvasively monitor angiogenesis, carcinogenesis, hypoxia, and pharmacokinetics. The high-definition PACT system with a 1024-element hemispherical ultrasound transducer array provides an isotropic spatial resolution of 380 μm, an effective volumetric field-of-view of 12.8 mm × 12.8 mm × 12.8 mm without scanning, and an acquisition time of <30 s for a whole mouse body. Initially, we monitor the structural progression of the tumor microenvironment (e.g., angiogenesis and vessel tortuosity) after tumor cell inoculation. Then, we analyze the change in oxygen saturation of the tumor during carcinogenesis, verifying induced hypoxia in the tumor's core region. Finally, the whole-body pharmacokinetics are photoacoustically imaged after intravenous injection of micelle-loaded IR780 dye, and the in vivo PACT results are validated in vivo and ex vivo by fluorescence imaging. By employing the premium PACT system and applying multiparametric analyses to subcutaneous primary tumors and metastatic liver tumors, we demonstrate that this PACT system can provide multiparametric analyses for comprehensive cancer research.

4 December 2024 in Advanced Science
Verified
Journal Article
Open access
JKJiwoong Kim
Jiwoong Kim
JKJoo Young Kweon
Joo Young Kweon
Seongwook ChoiSeongwook Choi
Seongwook Choi
HJHyunseo Jeon
Hyunseo Jeon
MSMinsik Sung
Minsik Sung
YAYong Joo Ahn
Yong Joo Ahn
Early‐stage stroke monitoring enables timely intervention that is crucial to minimizing neuronal damage and increasing the extent of recovery. By monitoring collateral circulation and neovascularization after ischemic stroke, the natural recovery process can be better understood, optimize further treatment strategies, and improve the prognosis. Photoacoustic computed tomography (PACT), a non‐invasive imaging modality that captures multiparametric high‐resolution images of vessel structures, is well suited for evaluating cerebrovascular structures and their function. Here 3D multiparametric transcranial PACT is implemented to monitor the early stage of a photothrombotic (PT)‐stroke model in living rats. New vessels in the PT‐induced region are successfully observed using PACT, and these observations are confirmed by histology. Then, using multiparametric PACT, it is found that the SO2 in the ischemic area decreases while the SO2 in newly formed vessels increases, and the SO2 in the PT region also recovers. These findings demonstrate PACT's remarkable ability to image and monitor cerebrovascular morphologic and physiological changes. They highlight the usefulness of whole‐brain PACT as a potentially powerful tool for early diagnosis and therapeutic decision‐making in treating ischemic stroke.