1 January 2017 in Proceedings of the Japan Academy, Series B
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
1 January 2021 in Brachytherapy
19 March 2023 in Journal of Applied Clinical Medical Physics
Purpose: We measure the dose distribution of gated delivery for different target motions and estimate the gating latency in a magnetic resonance‐guided radiotherapy (MRgRT) system.Method: The dose distribution accuracy of the gated MRgRT system (MRIdian, Viewray) was investigated using an in‐house‐developed phantom that was compatible with the magnetic field and gating method. This phantom contains a simulated tumor and a radiochromic film (EBT3, Ashland, Inc.). To investigate the effect of the number of beam switching and target velocity on the dose distribution, two types of target motions were applied. One is that the target was periodically moved at a constant velocity of 5 mm/s with different pause times (0, 1, 3, 10, and 20 s) between the motions. During different pause times, different numbers of beams were switched on/off. The other one is that the target was moved at velocities of 3, 5, 8, and 10 mm/s without any pause (i.e., continuous motion). The gated method was applied to these motions at MRIdian, and the dose distributions in each condition were measured using films. To investigate the relation between target motion and dose distribution in the gating method, we compared the results of the gamma analysis of the calculated and measured dose distributions. Moreover, we analytically estimated the gating latencies from the dose distributions measured using films and the gamma analysis results.Results: The gamma pass rate linearly decreased with increasing beam switching and target velocity. The overall gating latencies of beam‐hold and beam‐on were 0.51 ± 0.17 and 0.35 ± 0.05 s, respectively.Conclusions: Film measurements highlighted the factors affecting the treatment accuracy of the gated MRgRT system. Our analytical approach, employing gamma analysis on films, can be used to estimate the overall latency of the gated MRgRT system.
26 December 2022 in Journal of Applied Clinical Medical Physics
Background: The setup of lung shield (LS) in total body irradiation (TBI) with the computed radiography (CR) system is a time‐consuming task and has not been quantitatively evaluated. The TBI mobile imager (TBI‐MI) can solve this problem through real‐time monitoring. Therefore, this study aimed to perform commissioning and performance evaluation of TBI‐MI to promote its use in clinical practice.Methods: The source‐axis distance in TBI treatment, TBI‐MI (CNERGY TBI, Cablon Medical B.V.), and the LS position were set to 400, 450, and 358 cm, respectively. The evaluation items were as follows: accuracy of image scaling and measured displacement error of LS, image quality (linearity, signal‐to‐noise ratio, and modulation transfer function) using an EPID QC phantom, optimal thresholding to detect intra‐fractional motion in the alert function, and the scatter radiation dose from TBI‐MI.Results: The accuracy of image scaling and the difference in measured displacement of the LS was <4 mm in any displacements and directions. The image quality of TBI imager was slightly inferior to the CR image but was visually acceptable in clinical practice. The signal‐to‐noise ratio was improved at high dose rate. The optimal thresholding value to detect a 10‐mm body displacement was determined to be approximately 5.0%. The maximum fraction of scattering radiation to irradiated dose was 1.7% at patient surface.Conclusion: MI‐TBI can quantitatively evaluate LS displacement with acceptable image quality. Furthermore, real‐time monitoring with alert function to detect intrafraction patient displacement can contribute to safe TBI treatment.
9 September 2024 in Journal of Radiation Research
The present study aimed to summarize and report data on errors related to treatment planning, which were collected by medical physicists. The following analyses were performed based on the 10-year error report data: (1) listing of high-risk errors that occurred and (2) the relationship between the number of treatments and error rates, (3) usefulness of the Automated Plan Checking System (APCS) with the Eclipse Scripting Application Programming Interface and (4) the relationship between human factors and error rates. Differences in error rates were observed before and after the use of APCS. APCS reduced the error rate by ~1% for high-risk errors and 3% for low-risk errors. The number of treatments was negatively correlated with error rates. Therefore, we examined the relationship between the workload of medical physicists and error occurrence and revealed that a very large workload may contribute to overlooking errors. Meanwhile, an increase in the number of medical physicists may lead to the detection of more errors. The number of errors was correlated with the number of physicians with less clinical experience; the error rates were higher when there were more physicians with less experience. This is likely due to the lack of training among clinically inexperienced physicians. An environment to provide adequate training is important, as inexperience in clinical practice can easily and directly lead to the occurrence of errors. In any environment, the need for additional plan checkers is an essential factor for eliminating errors.