Kotaro Iijima

Kotaro Iijima

Auto-generated profile, based on publicly available information

Kotaro Iijima

Department of Radiation Oncology, Graduate School of Medicine, Juntendo University , Bunkyo-ku, Tokyo 113-8421

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Proceedings of the Japan Academy, Series B
Verified
Journal Article
Open access
PDF file
SNSatoshi Nakamura
Satoshi Nakamura
SIShoji Imamichi
Shoji Imamichi
KMKazuyoshi Masumoto
Kazuyoshi Masumoto
MIMasashi Ito
Masashi Ito
AWAkihisa Wakita
Akihisa Wakita
Jun ItamiJun Itami
Jun Itami
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies

1 January 2021 in Brachytherapy
Verified
Journal Article
Closed access
KIKotaro Iijima
Kotaro Iijima
NMNaoya Murakami
Naoya Murakami
SNSatoshi Nakamura
Satoshi Nakamura
SNShie Nishioka
Shie Nishioka
TCTakahito Chiba
Takahito Chiba
JIJun Itami
Jun Itami

19 March 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
HNHiroki Nakayama
Hiroki Nakayama
HOHiroyuki Okamoto
Hiroyuki Okamoto
SNSatoshi Nakamura
Satoshi Nakamura
KIKotaro Iijima
Kotaro Iijima
TCTakahito Chiba
Takahito Chiba
WCWeishan Chang
Weishan Chang
Purpose: We measure the dose distribution of gated delivery for different target motions and estimate the gating latency in a magnetic resonance‐guided radiotherapy (MRgRT) system.Method: The dose distribution accuracy of the gated MRgRT system (MRIdian, Viewray) was investigated using an in‐house‐developed phantom that was compatible with the magnetic field and gating method. This phantom contains a simulated tumor and a radiochromic film (EBT3, Ashland, Inc.). To investigate the effect of the number of beam switching and target velocity on the dose distribution, two types of target motions were applied. One is that the target was periodically moved at a constant velocity of 5 mm/s with different pause times (0, 1, 3, 10, and 20 s) between the motions. During different pause times, different numbers of beams were switched on/off. The other one is that the target was moved at velocities of 3, 5, 8, and 10 mm/s without any pause (i.e., continuous motion). The gated method was applied to these motions at MRIdian, and the dose distributions in each condition were measured using films. To investigate the relation between target motion and dose distribution in the gating method, we compared the results of the gamma analysis of the calculated and measured dose distributions. Moreover, we analytically estimated the gating latencies from the dose distributions measured using films and the gamma analysis results.Results: The gamma pass rate linearly decreased with increasing beam switching and target velocity. The overall gating latencies of beam‐hold and beam‐on were 0.51 ± 0.17 and 0.35 ± 0.05 s, respectively.Conclusions: Film measurements highlighted the factors affecting the treatment accuracy of the gated MRgRT system. Our analytical approach, employing gamma analysis on films, can be used to estimate the overall latency of the gated MRgRT system.

26 December 2022 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
TNTetsu Nakaichi
Tetsu Nakaichi
HOHiroyuki Okamoto
Hiroyuki Okamoto
MKMitsuhiro Kon
Mitsuhiro Kon
KTKazuki Takaso
Kazuki Takaso
AAAko Aikawa
Ako Aikawa
HIHiroshi Igaki
Hiroshi Igaki
Background: The setup of lung shield (LS) in total body irradiation (TBI) with the computed radiography (CR) system is a time‐consuming task and has not been quantitatively evaluated. The TBI mobile imager (TBI‐MI) can solve this problem through real‐time monitoring. Therefore, this study aimed to perform commissioning and performance evaluation of TBI‐MI to promote its use in clinical practice.Methods: The source‐axis distance in TBI treatment, TBI‐MI (CNERGY TBI, Cablon Medical B.V.), and the LS position were set to 400, 450, and 358 cm, respectively. The evaluation items were as follows: accuracy of image scaling and measured displacement error of LS, image quality (linearity, signal‐to‐noise ratio, and modulation transfer function) using an EPID QC phantom, optimal thresholding to detect intra‐fractional motion in the alert function, and the scatter radiation dose from TBI‐MI.Results: The accuracy of image scaling and the difference in measured displacement of the LS was <4 mm in any displacements and directions. The image quality of TBI imager was slightly inferior to the CR image but was visually acceptable in clinical practice. The signal‐to‐noise ratio was improved at high dose rate. The optimal thresholding value to detect a 10‐mm body displacement was determined to be approximately 5.0%. The maximum fraction of scattering radiation to irradiated dose was 1.7% at patient surface.Conclusion: MI‐TBI can quantitatively evaluate LS displacement with acceptable image quality. Furthermore, real‐time monitoring with alert function to detect intrafraction patient displacement can contribute to safe TBI treatment.

28 June 2024 in Cancers
Verified
Journal Article
Open access
PDF file
YMYoichi Muramoto
Yoichi Muramoto
NMNaoya Murakami
Naoya Murakami
NONoriyuki Okonogi
Noriyuki Okonogi
JTJun Takatsu
Jun Takatsu
KIKotaro Iijima
Kotaro Iijima
NSNaoto Shikama
Naoto Shikama
Purpose: Analyzing dose distributions to regional lymph-node metastases (RLNMs) in locally advanced cervical cancer (LACC) patients undergoing intracavitary and interstitial hybrid brachytherapy (IC/IS). Methods: Dose distributions of eleven LACC patients with 38 RLNMs, and who received 38 IC/IS sessions were analyzed in EQD2, considering RLNM positions and ipsilateral interstitial needles; these RLNMs, excepting the para-aortic region, were classified into four groups. Results: RLNMs had a median of two ipsilateral interstitial needles per session. Significant differences were observed in total RLNM D90, depending on whether the position was cranial or caudal of the uterine base (85.5 vs. 378.9 cGy, p < 0.0001), and whether the RLNM D90 was associated with a number of ipsilateral interstitial needles between 0–1 or 2 or more (68.4 vs. 112.2 cGy, p = 0.006) per session. At each session, Group 1 RLNMs (cranial of the uterine base, 0–1 ipsilateral interstitial needle) had a mean D90 of 21.1 cGy; Group 2 (cranial, 2 or more), 73.8; Group 3 (caudal, 0–1), 94.7; and Group 4 (caudal, 2 or more), 136.1. Conclusion: RLNMs located caudal of the uterine base associated with two or more ipsilateral interstitial needles in IC/IS had a higher dose contribution, which should be considered when calculating the RLNMs’ dose of external beam boost irradiation.

9 September 2024 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
KIKotaro Iijima
Kotaro Iijima
HNHiroki Nakayama
Hiroki Nakayama
SNSatoshi Nakamura
Satoshi Nakamura
TCTakahito Chiba
Takahito Chiba
YSYasunori Shuto
Yasunori Shuto
HOHiroyuki Okamoto
Hiroyuki Okamoto
The present study aimed to summarize and report data on errors related to treatment planning, which were collected by medical physicists. The following analyses were performed based on the 10-year error report data: (1) listing of high-risk errors that occurred and (2) the relationship between the number of treatments and error rates, (3) usefulness of the Automated Plan Checking System (APCS) with the Eclipse Scripting Application Programming Interface and (4) the relationship between human factors and error rates. Differences in error rates were observed before and after the use of APCS. APCS reduced the error rate by ~1% for high-risk errors and 3% for low-risk errors. The number of treatments was negatively correlated with error rates. Therefore, we examined the relationship between the workload of medical physicists and error occurrence and revealed that a very large workload may contribute to overlooking errors. Meanwhile, an increase in the number of medical physicists may lead to the detection of more errors. The number of errors was correlated with the number of physicians with less clinical experience; the error rates were higher when there were more physicians with less experience. This is likely due to the lack of training among clinically inexperienced physicians. An environment to provide adequate training is important, as inexperience in clinical practice can easily and directly lead to the occurrence of errors. In any environment, the need for additional plan checkers is an essential factor for eliminating errors.