Ataollah Taghipour Anvari

Ataollah Taghipour Anvari

Auto-generated profile, based on publicly available information

Ataollah Taghipour Anvari

Department of Civil and Material Engineering, University of Illinois at Chicago, Chicago, Illinois, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2019 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
AAAtaollah Taghipour Anvari
Ataollah Taghipour Anvari
MMMustafa Mahamid
Mustafa Mahamid
MMMichael McNallan
Michael McNallan
MEMohammadreza Eslami
Mohammadreza Eslami
Purpose: The purpose of this paper is to present the effect of damaged fireproofing on structural steel members. This study will show that a minor damage in fireproofing will reduce the fire rating of members significantly. Damaged fireproofing happens in structures due to various reasons, and the question is always how effective is this fireproofing? This paper presents the results of one type of fireproofing and presents a parametric study on the size of damage and its effect on fire resistance of structural steel members. Design/methodology/approach: The study has been performed using numerical methods, thermal and structural finite element analysis. The analysis method has been verified by experimental results. Findings: Small fire protection damage or loss leads to significant rise of temperature at the damaged parts and causes severe fire resistance reduction of beams. The higher fire protection damage’s extension at the bottom flange of the steel beams does not have any major influence on the rate of reduction of fire resistance of the beams. Steel beams experience greater fire resistance reduction at higher load levels because of the existing of higher stresses and loads within the steel beam section. Research limitations/implications: The study has been performed using finite element analysis, and it covers a wide range of practical sizes. However, experimental work will be performed by the researchers when funding is granted. Practical implications: The study provides researchers and practitioners with an estimate on the effect of damaged fireproofing on fire resistance of structural steel beams. Social implications: Understanding the effect of the effect of damaged fireproofing helps in estimating the fire resistance of structural steel members, which may protect collapses and disasters. Originality/value: The research is original; extensive literature review has been performed, and this research is original.

27 November 2018
Verified
Conference Paper
Closed access
HAHossein Ataei
Hossein Ataei
MMMustafa Mahamid
Mustafa Mahamid
Didem OzevinDidem Ozevin
Didem Ozevin
AAAtaollah Taghipour Anvari
Ataollah Taghipour Anvari
In November 2017, a 7.3-magnitude earthquake—the deadliest in 2017—happened 30 km southwest of Halabja, near the Iran-Iraq border. It was a shallow earthquake with its focus located at 11.8 miles below the ground surface. The death toll rose to 530 with nearly 7,900 wounded mainly in Iran’s western province of Kermanshah which was very close to the epicenter. The shockwaves were also felt in Turkey, Kuwait, and other neighboring countries. The earthquake left nearly 70,000 people homeless and in need for shelters. It caused damage to many buildings and devastated large areas in western Iran and eastern Iraq with majority of the lives lost and property damage to be concentrated in western Iran. The earthquake caused total or partial failure to many residential and commercial midrise buildings. It damaged a hospital and a few emergency response centers in nearby towns. The earthquake triggered major geotechnical failures that, in turn, made rescue efforts difficult. The Iran-Iraq border region is located above a highly active seismic zone where Arabian and Eurasian tectonic plates collide. Many houses in these rural regions are made of adobe and masonry and never certified or tested to withstand a seismic event. This paper aims to investigate the main reasons for building collapses and factors lead to such tragedy. It studies the lessons learned from emergency preparedness and crisis response efforts as well as the role of increased consciousness of natural disasters among all stakeholders—the agencies and the public.

4 April 2017
Verified
Conference Paper
Closed access
AAAtaollah Taghipour Anvari
Ataollah Taghipour Anvari
MMMustafa Mahamid
Mustafa Mahamid
MMMichael J. McNallan
Michael J. McNallan
Fireproofing is a passive fire protection applied structural steel members to reduce heat transfer to the structural steel members so that the rate of temperature rise of the load bearing components is reduced and a structural failure is delayed or does not occur. In other words, fireproofing helps the structural elements to properly function during a fire event for a certain period of time, also know as fire resistant rating. Different types of fireproofing applied to structural steel members such as concrete encasement, spray applied fire resistive materials (SFRM), intumescent coating, and gypsum board. This study focuses on the concrete encasement, which is widely used in oil and gas refineries and petrochemical facilities. Damage to fireproofing may occur due to accidental damage, long-term weathering, vibration, and improper application during construction. It is very important to understand how effective damaged fireproofing is since it is a phenomenon that occurs more often in practice. Damaged fireproofing or loss of fireproofing affects the strength and stiffness of structural steel members dramatically and raises the question of how effective is the remaining fireproofing during a fire event. Different types of damage such as extent of damaged fireproofing along the length of the members, partial loss of fireproofing across its thickness, and location of the damage. Failure modes, deflection, member capacity, and local instabilities were investigated at elevated temperature and compared with same members that are fully protected and without damage.