Ahmed M. Yassin

Ahmed M. Yassin

Auto-generated profile, based on publicly available information

Ahmed M. Yassin

Gilgamesh Ahliya University, Baghdad, Iraq

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2020 in Aesthetic Surgery Journal
Verified
Journal Article
Closed access
PDF file
MKMuholan Kanapathy
Muholan Kanapathy
MPMarc Pacifico
Marc Pacifico
AYAhmed M Yassin
Ahmed M Yassin
EBEdward Bollen
Edward Bollen
AMAfshin Mosahebi
Afshin Mosahebi
Background: Current literature clearly outlines the complication rates of liposuction in general; however, data specific to large-volume liposuction (LVL) remain unclear. Objectives: The authors aimed to synthesize the current evidence on the safety of LVL with this systematic review. Methods: A comprehensive search in the MEDLINE, EMBASE, and CENTRAL databases was conducted for primary clinical studies reporting on safety or complications related to aesthetic LVL from 1946 to March 2020. The primary outcome measure was the incidence of surgical complication, and the secondary outcome measure was changes in metabolic profile. Meta-analyses were conducted to pool the estimated surgical complication incidence and metabolic changes. Results: Twenty-three articles involving 3583 patients were included. The average aspirate volume was 7734.90 mL (95% CI = 5727.34 to 9742.45 mL). The pooled overall incidence of major surgical complications was 3.35% (95% CI = 1.07% to 6.84%). The most common major complication was blood loss requiring transfusion (2.89% [95% CI = 0.84% to 6.12%]) followed by pulmonary embolism (0.18% [95% CI = 0.06% to 0.33%]), hematoma (0.16% [95% CI = 0.05% to 0.32%]), necrotizing fasciitis (0.13% [95% CI = 0.04% to 0.29%]), and deep vein thrombosis (0.12% [95% CI = 0.03% to 0.27%]). No fat embolism or death was reported in the included studies. The pooled overall incidence of minor surgical complication was 11.62% (95% CI = 6.36% to 18.21%), with seroma being the most common minor complication (5.51% [95% CI = 2.69% to 9.27%]). Reductions in lipid profile, glucose profile, body weight, and hematocrit level were observed after LVL. Conclusions: The authors meta-analyzed and highlighted the complication rates specifically related to LVL in this study; however, the current data are limited by the lack of level 1 evidence. Level of Evidence: 4:

21 August 2023 in JPRAS Open
Verified
Journal Article
Open access
AYAhmed M. Yassin
Ahmed M. Yassin
MKMuholan Kanapathy
Muholan Kanapathy
AKAmr M.E. Khater
Amr M.E. Khater
AEAhmed Hassan El-Sabbagh
Ahmed Hassan El-Sabbagh
OSOmar Shouman
Omar Shouman
Afshin MosahebiAfshin Mosahebi
Afshin Mosahebi
In this study, we evaluate the versatility of smartphone thermal imaging technology as a valuable intraoperative modality in different stages of perforator flap surgery aiming to minimize the complications and achieve the best postoperative outcome. Thermography was performed in 20 perforator flaps in 20 patients at different surgical stages in three different ways to identify the most dominant perforator: first, by measuring the surface temperature of the skin; second, by using the dynamic infrared thermography technique; and third, by assessing the perfusion pattern when the flap was supplied by each perforator separately. Thermography was used to help in discarding the least perfused area of the flap. After microvascular anastomosis, the flap reheating pattern was evaluated. Seventeen free and three pedicled perforator flaps were included. Intraoperatively, each of the selected perforators had a corresponding hotspot. The perforator with the hottest hotpot, best rewarming, and provision of best flap perfusion on thermography was found clinically dominant. After microvascular anastomosis in free flaps, rapid rewarming was recorded in 15 cases. In two deep inferior epigastric perforator flaps, no rapid rewarming was observed. The pedicle was kinked in one case and there was a venous insufficiency in another case that required a cephalic turndown. All flaps showed good perfusion on thermography after inset. Smartphone thermography has proven to be a valuable, cheap, rapidly employed, and objective tool not only for the design of perforator flaps, but also for the decision making intraoperatively to achieve the best surgical outcome.

24 November 2022 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
RFRyan Faderani
Ryan Faderani
AYAhmed M Yassin
Ahmed M Yassin
CBChevonne Brady
Chevonne Brady
PCPaul Caine
Paul Caine
DNDariush Nikkhah
Dariush Nikkhah

15 July 2025 in Journal of Computational Biophysics and Chemistry
Verified
Journal Article
Closed access
AMAhmed Faisal Mutee
Ahmed Faisal Mutee
ASAbdulkareem Shareef
Abdulkareem Shareef
SRS. RenukaJyothi
S. RenukaJyothi
RPRajashree Panigrahi
Rajashree Panigrahi
VAVikrant Abbot
Vikrant Abbot
MAMohaned Adil
Mohaned Adil

1 February 2022 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
CKConstantinos Kokkinos
Constantinos Kokkinos
AYAhmed M. Yassin
Ahmed M. Yassin
DNDariush Nikkhah
Dariush Nikkhah

26 April 2023
Verified
Book Chapter
Closed access
PDF file
AYAhmed M. Yassin
Ahmed M. Yassin
MKMuholan Kanapathy
Muholan Kanapathy
GPGeorgios Pafitanis
Georgios Pafitanis