Merve Botsalı

Merve Botsalı

Auto-generated profile, based on publicly available information

Merve Botsalı

Department of Prosthodontics, Faculty of Dentistry, University of Sakarya, Sakarya, Türkiye

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2025 in Current Research in Dental Sciences
Verified
Journal Article
Open access
PDF file
MBMerve Botsalı
Merve Botsalı
SDSibel Dikicier
Sibel Dikicier
HBHüseyin Botsalı
Hüseyin Botsalı
AAArzu Atay
Arzu Atay
Objective: The aim of the study is to evaluate the stress distribution of zirconia-reinforced lithium silicate all-ceramic fixed partial dentures under occlusal loading; in terms of material, restoration, and supporting type. Methods: Six different models were analyzed; tooth-supported anterior crown, tooth-supported posterior crown, tooth-supported 3-unit bridge, implant-supported anterior crown, implant-supported posterior crown and implant-supported 3-unit bridge. Milling and pressable zirconia-reinforced lithium silicate were used in each model. Structural analyses were simulated with finite element analysis under vertical and oblique loading to evaluate the von Mises and minimum principal stresses. Results: Tooth-supported restorations showed lower stress values than implant-supported forms of the same restoration. Stresses were higher and distributed over a larger surface under oblique loading compared to vertical loading. Overall stresses generated on the single crown models were higher than the stresses generated on the bridge models. Implant-supported bridge model under oblique loading shows the highest stress. However both milling and pressable forms of zirconia-reinforced lithium silicate didn’t make a difference on the stress concentration and distribution areas. Conclusion: The stress distribution and mechanical behavior of models was influenced by the type of restoration, direction of the force, and the number of units. However, no significant difference was found between milling and pressable zirconia-reinforced lithium silicate ceramic in terms of the stress values on the restorations.

30 December 2025 in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
Verified
Journal Article
Closed access
MBMerve Botsali
Merve Botsali
HBHüseyin Botsalı
Hüseyin Botsalı
Aim: In this study, it was conducted to examine the effect of the stress distribution of different restorative materials on the crown, abutment, implant and bone on the biomechanical behavior and safety factor of the materials. Material and Methods: Zirconia, lithium disilicate, and zirconia-reinforced lithium silicate ceramics were designed on a single implant-supported crown that replaced the missing lower first molar. The stresses of the components of the models and the safety factors of the crown materials were calculated after 400 N occlusal loading. Results: The zirconia model caused the lowest stress on the implant but the highest stress on the crown. When the elastic modulus of the material increased, the stress on the crown increased, but the stress transmitted to the implant decreased. However, despite this high stress in the crown, the highest safety factor was in zirconia. Conclusion: The safety factor of the restoration material depends on the flexural strength rather than the stress on the crown. The greater the flexural strength, the greater the safety factor, and for a long-surviving implant-supported restoration, it is important that the crown material has a high safety factor and low stress on the implant.

1 January 2026 in International Journal of Dentistry
Verified
Journal Article
Open access
MKMerve Koseoglu
Merve Koseoglu
RRRemya Ampadi Ramachandran
Remya Ampadi Ramachandran
MBMerve Botsalı
Merve Botsalı
Cortino SukotjoCortino Sukotjo
Cortino Sukotjo
Background: Information regarding the prediction of dentistry students’ academic performances using machine learning (ML) techniques is lacking. The objective of this study was to predict the academic performance of pre‐clinical dentistry students using ML techniques based on their pre‐university information. Methods: A total of 96 data points, including graduation years, genders, high school grade point average (GPA), step 1 university exam score (Step 1 UES), Step 2 UES, total UES, university exam ratings (UER), high school types (HSTypes), hometowns, parent educations (PEs), and parent incomes (PIs) from dentistry grads, were collected. Various ML regression techniques were validated to predict the academic performance of dentistry students in this cross‐sectional study. Results: Preliminary findings from the dataset indicated that UESs or rankings were more predictive than other demographic features, such as HSType, gender, graduation year, and hometown. The selection of target variables has resulted in two major studies. The initial study employed overall preclinical scores as the target variable, whereas the subsequent study utilized letter grades from specific preclinical courses, including dental morphology manipulation, dental materials I, prosthodontics I, and prosthodontics II, for ML models. The performance measures of these models demonstrated the capability of ML models to evaluate student performance in relation to demographics, high school performance, and admission scores. Regression models exhibiting an R 2 value of 0.74 or greater, alongside a classification accuracy beyond 70% for a balanced dataset of preclinical subject scores, demonstrated that ML models can predict student achievement in both overall and subject‐specific grades. Conclusion: The present study revealed the utilization of ML techniques to predict the academic performance of dentistry students successfully.