Objective: The long-term durability of transcatheter aortic bioprosthetic valves continues to be a major concern. Standardized criteria of the structural valve deterioration (SVD) and bioprosthetic valve failure (BVF) have recently been defined. Limited studies have evaluated the longterm durability of transcatheter aortic valve implantation (TAVI) according to these new definitions. We aim to analyze the durability of TAVI beyond 5 years and to report the frequency of SVD and BVF. Methods: A total of 89 patients who had undergone TAVI and had theoretically completed at least 5 years after the procedure were included. Either a Medtronic CoreValve or an Edwards SAPIEN XT valve were implanted in the patients. New standardized definitions were used to evaluate SVD and BVF. Results: The mean age of the patients was 78.70 +/- 6.95 years. SVD occured in 4 (4.5%) patients during 6 years of follow-up. Severe SVD was observed in 2 patients (2.2%), and these patients had the New York Heart Association class II symptoms. Both patients with severe SVD also met the criteria of BVF. Moderate SVD was observed in 2 patients (2.2%), and these patients had no valve-related symptoms. Of the 4 SVD cases, 2 were associated with increased mean transaortic gradients, whereas the remaining 2 cases were associated with intraprosthetic aortic regurgitation. All patients with SVD are still alive, and none of them have required aortic valve reintervention. Conclusion: Although first-generation TAVI devices were used, we determined the low rate of SVD and BVF at the 6-year follow-up. It may be suggested that there is no major concern associated with TAVI even with first-generation devices regarding long-term durability.
18 September 2025 in Thoracic Research and Practice
Impact of Inspiratory Muscle Strength and Lung Function on Functional Exercise Capacity in Post-myocardial Infarction Patients: A Cross-sectional Study - Thoracic Research and Practice
Background: Immunopathological dysregulation has been implicated as a unifying substrate for both atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF), 2 conditions that cluster with disproportionate frequency in clinical cardiology practice. Systemic immune-inflammation index (SII)—a hematological index derived from the ratio of platelet–neutrophil product to lymphocyte count—has garnered increasing attention as a low-burden inflammatory surrogate. The capacity to discriminate AF from sinus rhythm was investigated in an outpatient cohort with HFpEF. Methods: A retrospective analysis was conducted on 207 HFpEF outpatients (January 2024-January 2025) stratified by resting electrocardiogram rhythm: sinus rhythm (group 1, n = 105) vs. AF (group 2, n = 102). Independent AF predictors were identified through multivariate binary logistic regression. Results: Four variables independently predicted AF on multivariate analysis: SII (P = .04), age (P = .010), left atrial diameter (P < .001), and systolic pulmonary artery pressure (P < .001). At an optimal SII threshold of 584.64, sensitivity reached 79.4% and specificity 59% for AF prediction (AUC = 0.727, 95% CI = 0.658-0.796, P < .001). Conclusion: Systemic immune-inflammation index constitutes a cost-neutral, universally derivable hematological parameter with meaningful clinical utility for AF risk stratification within the HFpEF phenotype. Patients harboring pronounced SII elevation warrant heightened arrhythmia vigilance through serial 12-lead recordings and extended ambulatory electrocardiographic monitoring—should be considered in HFpEF patients with markedly elevated SII to facilitate timely AF detection. Cite this article as: Şentürk B, Kış M, Çöllüoğlu T, et al. The relationship between the systemic immune inflammatory index and atrial fibrillation in heart failure with preserved ejection fraction. Eurasian J Med. 2026, 58(4), 1589, doi: 10.5152/ eurasianjmed.2026.261589.
8 September 2023 in International Journal of the Cardiovascular Academy
Preparticipation screening of athletes by electrocardiography is the most crucial step in determining sudden cardiac death risk factors. Several electrocardiography interpretation software programs have been developed for physicians practicing in this field. Our study aimed to assess cardiopoint sudden death screening module by comparing its findings with two cardiologists using Seattle and International criteria.