Rosse Mary Falcón-Antenucci

Rosse Mary Falcón-Antenucci

Auto-generated profile, based on publicly available information

Rosse Mary Falcón-Antenucci

Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University-UNESP, Brazil

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
LTLeonardo Bueno Torcato
Leonardo Bueno Torcato
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
FVFelippo Ramos Verri
Felippo Ramos Verri
RFRosse Mary Falcón-Antenucci
Rosse Mary Falcón-Antenucci
JJJoel Ferreira Santiago Júnior
Joel Ferreira Santiago Júnior
DADaniel Augusto de Faria Almeida
Daniel Augusto de Faria Almeida

1 March 2011 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
RFRosse Mary Dds Falcón-Antenucci
Rosse Mary Dds Falcón-Antenucci
PCPaulo Sérgio Perri de Carvalho
Paulo Sérgio Perri de Carvalho
DSDaniela Mayumi Inatomi Kavano Sánchez
Daniela Mayumi Inatomi Kavano Sánchez
GRGabriel Augusto Tozo Rinaldi
Gabriel Augusto Tozo Rinaldi
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
The aim of this study was to perform a photoelastic analysis of stress distribution on straight and angulated implants with different crowns (screwed and cemented). Three models were made of photoelastic resin PL-2: model 1: external hexagon implant 3.75 × 10.00 mm at 0 degrees; model 2: external hexagon implant 3.75 × 10.00 mm at 17 degrees; model 3: external hexagon implant 3.75 × 10.00 mm at 30 degrees. Axial and oblique (45 degrees) load (100 N) was applied with a universal testing machine. The photoelastic fringes on the models were recorded with a digital camera and visualized in a graphic software for qualitative analysis. The axial loading generated the same pattern of stress distribution. The highest stresses were concentrated between medium and apical thirds. The oblique loading generated a similar pattern of stress distribution in the models with similar implant angulation; the highest stress was located on the cervical region opposite to implant angulation and on the apical third. It was concluded that the higher the implant angulation, the higher the stress value, independent of crown type. The screwed prostheses exhibited the highest stress concentration. The oblique load generated higher stress value and concentration than the axial load.

1 July 2010 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
RFRosse Mary Falcón‐Antenucci
Rosse Mary Falcón‐Antenucci
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
PCPaulo Sergio Perri De Carvalho
Paulo Sergio Perri De Carvalho
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
PNPedro Yoshito Noritomi
Pedro Yoshito Noritomi

1 May 2010 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
FVFelippo Ramos Verri
Felippo Ramos Verri
RFRosse Mary Falcón-Antenucci
Rosse Mary Falcón-Antenucci
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
HFHumberto Gennari Filho
Humberto Gennari Filho
The aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees). Finite element analysis was performed in ANSYS 9.0. model E showed the higher displacement and overload in the supporting tissues; the patterns of stress distribution around the dental apex of models B, C, and D were similar. The association between a DERPD and an osseointegrated implant using the ERA or O'ring systems shows lower stress values. Oblique forces showed higher stress values and displacement. Oblique forces increased the displacement and stress levels in all models; model C displayed the best stress distribution in the supporting structures; healing abutment, ERA, and O'ring systems were viable with RPD, but DERPD association with a single implant-supported prosthesis was nonviable.

1 August 2011 in Journal of Oral Implantology
Verified
Journal Article
Closed access
BTBianca Piccolotto Tonella
Bianca Piccolotto Tonella
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
RFRenato Ferraço
Renato Ferraço
RFRosse Mary Falcón-Antenucci
Rosse Mary Falcón-Antenucci
PCPaulo S. Perri de Carvalho
Paulo S. Perri de Carvalho
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
The aim of this study was to evaluate the stress distribution of different retention systems (screwed or cemented) associated with different prosthetic connections (external hexagon, internal hexagon, and Morse taper) in 3-unit implant-supported fixed partial dentures through photoelasticity. Six models were fabricated with photoelastic resin PL-2, and each model contained two implants of 4.0 × 10.0 mm. The models presented different retention systems (screwed and cemented) and different connections (external hexagon, internal hexagon, and Morse taper). The prostheses were standardized and fabricated in Ni-Cr alloy. A circular polariscope was used and axial and oblique (45°) loads of 100 N were applied in a universal testing machine. The results were photographed and analyzed qualitatively with a graphic software (Adobe Photoshop). The screwed retention system exhibited higher number of fringes for both axial and oblique loadings. The internal hexagon implant presented better and lower stress distribution for both cemented and screwed prostheses. The oblique loading increased the number of fringes in all models tested. The cemented retention system presented better stress distribution. The internal hexagon implant was more favorable according to the biomechanical standpoint. The oblique load increased stress in all systems and connections tested.

1 April 2014 in Journal of Oral Implantology
Verified
Journal Article
Closed access
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
RCRafael Imai Carli
Rafael Imai Carli
RFRosse Mary Falcón-Antenucci
Rosse Mary Falcón-Antenucci
FVFelippo Ramos Verri
Felippo Ramos Verri
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
LVLuiz Marcelo Ribeiro Villa
Luiz Marcelo Ribeiro Villa
The aim of this study was to evaluate stress distribution with different implant systems through photoelasticity. Five models were fabricated with photoelastic resin PL-2. Each model was composed of a block of photoelastic resin (10 × 40 × 45 mm) with an implant and a healing abutment: model 1, internal hexagon implant (4.0 × 10 mm; Conect AR, Conexão, São Paulo, Brazil); model 2, Morse taper/internal octagon implant (4.1 × 10 mm; Standard, Straumann ITI, Andover, Mass); model 3, Morse taper implant (4.0 × 10 mm; AR Morse, Conexão); model 4, locking taper implant (4.0 × 11 mm; Bicon, Boston, Mass); model 5, external hexagon implant (4.0 × 10 mm; Master Screw, Conexão). Axial and oblique load (45°) of 150 N were applied by a universal testing machine (EMIC-DL 3000), and a circular polariscope was used to visualize the stress. The results were photographed and analyzed qualitatively using Adobe Photoshop software. For the axial load, the greatest stress concentration was exhibited in the cervical and apical thirds. However, the highest number of isochromatic fringes was observed in the implant apex and in the cervical adjacent to the load direction in all models for the oblique load. Model 2 (Morse taper, internal octagon, Straumann ITI) presented the lowest stress concentration, while model 5 (external hexagon, Master Screw, Conexão) exhibited the greatest stress. It was concluded that Morse taper implants presented a more favorable stress distribution among the test groups. The external hexagon implant showed the highest stress concentration. Oblique load generated the highest stress in all models analyzed.