1 November 2024 in EP Europace
Aims: A novel three-dimensional mapping platform combined with a lattice-tip catheter that can toggle between monopolar pulsed field ablation (PFA) and radiofrequency energy delivery was recently launched. So far, the system was predominantly applied in general anaesthesia (GA), not in deep sedation. Methods and results: Patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) were enrolled, and pulmonary vein isolation (PVI) and ablation of additional linear lesion sets were performed either in GA or in deep sedation. Pulsed field ablation was applied exclusively to perform ipsilateral PVI. A total of 63 patients (35% female, 75% persistent AF, mean age 64 ± 9 years) were included in the analysis with 23 patients treated in GA and 40 patients in deep sedation. Acute efficacy was comparable in both groups with a PVI rate of 100%. Additional 74 lesion sets were performed in the total cohort. Mean procedure and lab occupancy time in the GA and deep sedation group was 96 ± 24 min vs. 100 ± 23 min (P = 0.52) and 165 ± 40 min vs. 131 ± 35 min (P = 0.0008). Mean dose area product was 489 (216;1093) vs. 452 (272;882) cGycm2 in the GA and the deep sedation group (P = 0.82). There was one conversion from deep sedation to GA. There were no map shifts observed in any group. Pericardial tamponade occurred in one patient of the deep sedation group. Conclusion: The use of a novel ablation platform in conjunction with a lattice-tip catheter in deep sedation is feasible, effective, and associated with significantly shorter lab occupancy time when compared with GA.
3 June 2024 in EP Europace
Technological advancements have contributed to the enhanced precision and lesion flexibility in pulsed-field ablation (PFA) by integrating a three-dimensional mapping system combined with a point-by-point ablation strategy. Data regarding the feasibility of this technology remain limited to some clinical trials. This study aims to elucidate initial real-world data on catheter ablation utilizing a lattice-tip focal PFA/radiofrequency ablation (RFA) catheter in patients with persistent atrial fibrillation (AF). Consecutive patients who underwent catheter ablation for persistent AF via the lattice-tip PFA/RFA catheter were enrolled. We evaluated acute procedural data including periprocedural data as well as the clinical follow-up within a 90-day blanking period. In total, 28 patients with persistent AF underwent AF ablation either under general anaesthesia (n = 6) or deep sedation (n = 22). In all patients, pulmonary vein isolation was successfully achieved. Additional linear ablations were conducted in 21 patients (78%) with a combination of successful anterior line (n = 13, 46%) and roof line (n = 19, 68%). The median procedural and fluoroscopic times were 97 (interquartile range, IQR: 80–114) min and 8.5 (IQR: 7.2–9.5) min, respectively. A total of 27 patients (96%) were interviewed during the follow-up within the blanking period, and early recurrent AF was documented in four patients (15%) including one case of recurrent AF during the hospital stay. Neither major nor minor procedural complication occurred. In terms of real-world data, our data confirmed AF ablation feasibility utilizing the lattice-tip focal PFA/RFA catheter in patients with persistent AF.
26 May 2023 in World Journal of Cardiology
Hospitalizations for heart failure exceed 1 million per year in both the United States and Europe and more than 90% are due to symptoms and signs of fluid overload. Rates of rehospitalizations or emergency department visit at 60 days are remarkable regardless of whether loop diuretics were administered at low vs high doses or by bolus injection vs continuous infusion. Ultrafiltration (UF) has been considered a promising alternative to stepped diuretic therapy and it consists in the mechanical, adjustable removal of iso-tonic plasma water across a semipermeable membrane with the application of hydrostatic pressure gradient generated by a pump. Fluid removal with ultrafiltration presents several advantages such as elimination of higher amount of sodium with less neurohormonal activation. However, the conflicting results from UF studies highlight that patient selection and fluid removal targets are not completely understood. The best way to assess fluid status and therefore establish the fluid removal target is also still a matter of debate. Herein, we provide an up-to-date systematic review about the role of ultrafiltration among patients with fluid overload and its gaps in daily practice.
26 July 2022 in Oxford Medical Case Reports
Erdheim-Chester disease (ECD) is a rare multisystemic disorder of non-Langerhans histiocytic cells with a pleomorphic clinical presentation. It affects bones, skin, central nervous system, pituitary gland, ocular tissue, kidneys and perirenal tissue and lungs. Cardiac involvement presents usually with pericardial effusion and right atrial masses, but rarely with conduction system infiltration and subsequent arrhythmic events. Following the discovery of mutations of activating signaling kinase proteins (BRAF, MEK, ALK), the therapeutic landscape has changed to a more precise targeted treatment. Currently vemurafenib is approved for patient with end-organ dysfunction and BRAF-V600E mutation and the prognosis has dramatically improved. Here we present a case of ECD with electrical instability as main clinically relevant manifestation of cardiac involvement.
5 February 2026 in Expert Review of Medical Devices
Percutaneous left atrial appendage closure (LAAC) is an increasingly relevant strategy for stroke prevention in patients with non-valvular atrial fibrillation (AF) who are ineligible for long-term oral anticoagulation. Its clinical relevance continues to expand as device technology and operator experience evolve. This review provides an updated synthesis of currently available LAAC devices - including contemporary and emerging technologies - and summarizes comparative evidence from major trials and registries. A structured literature search was performed in PubMed, Scopus, and Web of Science. Additional focus is dedicated to expanding clinical applications, including use in chronic kidney disease, persistent left atrial appendage thrombus, stroke despite anticoagulation, and combined procedures such as LAAC with atrial fibrillation ablation. LAAC is entering a new phase in which its role may broaden beyond traditional indications, driven by improved safety, individualized antithrombotic strategies, and promising innovations such as dual‑seal and exclusion‑based devices. Future research will determine whether LAAC can transition from a selective therapy into a mainstream option for stroke prevention.
30 July 2026 in EP Europace
Aims: Pulsed field ablation (PFA) is a non-thermal energy modality for ablation of atrial fibrillation (AF). Although PFA has demonstrated an excellent overall safety profile, increasing evidence suggests an association with intravascular haemolysis, and acute kidney injury (AKI). However, the extent of haemolysis across different PFA catheters remains poorly characterized and warrants further investigation. Methods and results: We prospectively enrolled 239 patients undergoing AF ablation using the pentaspline (n = 107), balloon-in-basket (n = 71), or lattice-tip (n = 61) catheter. Laboratory markers of haemolysis, myocardial injury, renal function and haemoglobin were collected pre- and 24h post-procedure. Significant haptoglobin depletion was observed exclusively with pentaspline, [pre 99.8 mg/dL (70.2–122) vs. post 55.7 mg/dL (23.2–91.8); P < 0.001] Reductions with the lattice-tip (P = 0.074) and the balloon-in-basket (P = 0.201) catheter did not reach statistical significance. AKI was only observed with the pentaspline catheter (pentaspline: 4.9%; balloon-in-basket: 0.0%; lattice tip: 0.0%; P = 0.020). Myocardial markers increased across all groups, but significantly higher in pentaspline and balloon-in-basket (P = n.s.) vs. lattice-tip (P < 0.001 vs. pentaspline, P < 0.001 vs. balloon in basket). Conclusion: In this large cohort, contemporary PFA systems appear safe but catheter design influences the extent of haemolysis, AKI, and myocardial injury. The pentaspline catheter was associated with the greatest haemolytic effect and higher transient AKI, without clinically relevant reductions in haemoglobin or persistent renal impairment. Higher levels of myocardial injury in the pentaspline and balloon-in-basket groups correspond to the larger lesion footprints of these devices.