Polymer–carbon nanotube composite coatings have properties that are desirable for a wide range of applications. However, fabrication of these coatings onto submillimeter structures with the efficient use of nanotubes has been challenging. Polydimethylsiloxane (PDMS)–carbon nanotube composite coatings are of particular interest for optical ultrasound transmission, which shows promise for biomedical imaging and therapeutic applications. In this study, methods for fabricating composite coatings comprising PDMS and multiwalled carbon nanotubes (MWCNTs) with submicrometer thickness are developed and used to coat the distal ends of optical fibers. These methods include creating a MWCNT organogel using two solvents, dip coating of this organogel, and subsequent overcoating with PDMS. These coated fibers are used as all‐optical ultrasound transmitters that achieve high ultrasound pressures (up to 21.5 MPa peak‐to‐peak) and broad frequency bandwidths (up to 39.8 MHz). Their clinical potential is demonstrated with all‐optical pulse‐echo ultrasound imaging of an aorta. The fabrication methods in this paper allow for the creation of thin, uniform carbon nanotube composites on miniature or temperature‐sensitive surfaces, to enable a wide range of advanced sensing capabilities.
In this paper, we experimentally demonstrate for the first time an on off keying modulated visible light communications system achieving 170 Mb/s using an artificial neural network (ANN) based equalizer. Adaptive decision feedback (DF) and linear equalizers are also implemented and the system performances are measured using both real time (TI TMS320C6713 digital signal processing board) and offline (MATLAB) implementation of the equalizers. The performance of each equalizer is analyzed in this paper using a low bandwidth (4.5 MHz) light emitting diode (LED) as the transmitter and a large bandwidth (150 MHz) PIN photodetector as the receiver. The achievable data rates using the white spectrum are 170, 90, 40 and 20 Mb/s for ANN, DF, linear and unequalized topologies, respectively. Using a blue filter to isolate the fast blue component of the LED (at the cost of the power contribution of the yellowish wavelengths) is a popular method of improving the data rate. We further demonstrate that it is possible to sustain higher data rates from the white light with ANN equalization than the blue component due to the high signal-to-noise ratio that is obtained from retaining the yellowish wavelengths. Using the blue component we could achieve data rates of 150, 130, 90 and 70 Mb/s for the same equalizers, respectively.
High-frequency ultrasound imaging can provide exquisite visualizations of tissue to guide minimally invasive procedures. Here, we demonstrate that an all-optical ultrasound transducer, through which light guided by optical fibers is used to generate and receive ultrasound, is suitable for real-time invasive medical imaging in vivo. Broad-bandwidth ultrasound generation was achieved through the photoacoustic excitation of a multiwalled carbon nanotube-polydimethylsiloxane composite coating on the distal end of a 300-μm multi-mode optical fiber by a pulsed laser. The interrogation of a high-finesse Fabry–Pérot cavity on a single-mode optical fiber by a wavelength-tunable continuous-wave laser was applied for ultrasound reception. This transducer was integrated within a custom inner transseptal needle (diameter 1.08 mm; length 78 cm) that included a metallic septum to acoustically isolate the two optical fibers. The use of this needle within the beating heart of a pig provided unprecedented real-time views (50 Hz scan rate) of cardiac tissue (depth: 2.5 cm; axial resolution: 64 μm) and revealed the critical anatomical structures required to safely perform a transseptal crossing: the right and left atrial walls, the right atrial appendage, and the limbus fossae ovalis. This new paradigm will allow ultrasound imaging to be integrated into a broad range of minimally invasive devices in different clinical contexts.