Yihao Liu

Yihao Liu

Auto-generated profile, based on publicly available information

Yihao Liu

Vanderbilt University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2024 in Medical Image Analysis
Verified
Journal Article
Closed access
JCJunyu Chen
Junyu Chen
YLYihao Liu
Yihao Liu
SWShuwen Wei
Shuwen Wei
ZBZhangxing Bian
Zhangxing Bian
SSShalini Subramanian
Shalini Subramanian
YDYong Du
Yong Du

14 August 2023 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Open access
LZLianrui Zuo
Lianrui Zuo
YLYihao Liu
Yihao Liu
YXYuan Xue
Yuan Xue
BDBlake E. Dewey
Blake E. Dewey
SRSamuel W. Remedios
Samuel W. Remedios
ACAaron Carass
Aaron Carass
The lack of standardization and consistency of acquisition is a prominent issue in magnetic resonance (MR) imaging. This often causes undesired contrast variations in the acquired images due to differences in hardware and acquisition parameters. In recent years, image synthesis-based MR harmonization with disentanglement has been proposed to compensate for the undesired contrast variations. The general idea is to disentangle anatomy and contrast information from MR images to achieve cross-site harmonization. Despite the success of existing methods, we argue that major improvements can be made from three aspects. First, most existing methods are built upon the assumption that multi-contrast MR images of the same subject share the same anatomy. This assumption is questionable, since different MR contrasts are specialized to highlight different anatomical features. Second, these methods often require a fixed set of MR contrasts for training (e.g., both T1-weighted and T2-weighted images), limiting their applicability. Lastly, existing methods are generally sensitive to imaging artifacts. In this paper, we present Harmonization with Attention-based Contrast, Anatomy, and Artifact Awareness (HACA3), a novel approach to address these three issues. HACA3 incorporates an anatomy fusion module that accounts for the inherent anatomical differences between MR contrasts. Furthermore, HACA3 can be trained and applied to any combination of MR contrasts and is robust to imaging artifacts. HACA3 is developed and evaluated on diverse MR datasets acquired from 21 sites with varying field strengths, scanner platforms, and acquisition protocols. Experiments show that HACA3 achieves state-of-the-art harmonization performance under multiple image quality metrics. We also demonstrate the versatility and potential clinical impact of HACA3 on downstream tasks including white matter lesion segmentation for people with multiple sclerosis and longitudinal volumetric analyses for normal aging subjects. Code is available at https://github.com/lianruizuo/haca3.

18 April 2024 in International Journal of Computer Vision
Verified
Journal Article
Open access
PDF file
YLYihao Liu
Yihao Liu
JCJunyu Chen
Junyu Chen
SWShuwen Wei
Shuwen Wei
ACAaron Carass
Aaron Carass
JPJerry L Prince
Jerry L Prince
Producing spatial transformations that are diffeomorphic is a key goal in deformable image registration. As a diffeomorphic transformation should have positive Jacobian determinant $$\vert J\vert $$ | J | everywhere, the number of pixels (2D) or voxels (3D) with $$\vert J\vert <0$$ | J | < 0 has been used to test for diffeomorphism and also to measure the irregularity of the transformation. For digital transformations, $$\vert J\vert $$ | J | is commonly approximated using a central difference, but this strategy can yield positive $$\vert J\vert $$ | J | ’s for transformations that are clearly not diffeomorphic—even at the pixel or voxel resolution level. To show this, we first investigate the geometric meaning of different finite difference approximations of $$\vert J\vert $$ | J | . We show that to determine if a deformation is diffeomorphic for digital images, the use of any individual finite difference approximation of $$\vert J\vert $$ | J | is insufficient. We further demonstrate that for a 2D transformation, four unique finite difference approximations of $$\vert J\vert $$ | J | ’s must be positive to ensure that the entire domain is invertible and free of folding at the pixel level. For a 3D transformation, ten unique finite differences approximations of $$\vert J\vert $$ | J | ’s are required to be positive. Our proposed digital diffeomorphism criteria solves several errors inherent in the central difference approximation of $$\vert J\vert $$ | J | and accurately detects non-diffeomorphic digital transformations. The source code of this work is available at https://github.com/yihao6/digital_diffeomorphism.

12 October 2022
Verified
Book Chapter
Closed access
PDF file
YLYihao Liu
Yihao Liu
LZLianrui Zuo
Lianrui Zuo
SHShuo Han
Shuo Han
YXYuan Xue
Yuan Xue
JPJerry L. Prince
Jerry L. Prince
ACAaron Carass
Aaron Carass

21 July 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
YLYihao Liu
Yihao Liu
ACAaron Carass
Aaron Carass
LZLianrui Zuo
Lianrui Zuo
YHYufan He
Yufan He
SHShuo Han
Shuo Han
JPJerry L Prince
Jerry L Prince
Optical coherence tomography angiography (OCTA) is an imaging modality that can be used for analyzing retinal vasculature. Quantitative assessment of en face OCTA images requires accurate segmentation of the capillaries. Using deep learning approaches for this task faces two major challenges. First, acquiring sufficient manual delineations for training can take hundreds of hours. Second, OCTA images suffer from numerous contrast-related artifacts that are currently inherent to the modality and vary dramatically across scanners. We propose to solve both problems by learning a disentanglement of an anatomy component and a local contrast component from paired OCTA scans. With the contrast removed from the anatomy component, a deep learning model that takes the anatomy component as input can learn to segment vessels with a limited portion of the training images being manually labeled. Our method demonstrates state-of-the-art performance for OCTA vessel segmentation.

14 June 2021
Verified
Book Chapter
Closed access
PDF file
LZLianrui Zuo
Lianrui Zuo
BDBlake E. Dewey
Blake E. Dewey
ACAaron Carass
Aaron Carass
YLYihao Liu
Yihao Liu
YHYufan He
Yufan He
JPJerry L Prince
Jerry L Prince