Hungwen Lin

Hungwen Lin

Auto-generated profile, based on publicly available information

Hungwen Lin

Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013
Verified
Report
Open access
PDF file
THTianzhen Hong
Tianzhen Hong
HLHung-Wen Lin
Hung-Wen Lin
WCWen-Kuei Chang
Wen-Kuei Chang
LWLiping Wang
Liping Wang
WTWilliam Turner
William Turner
XRXiaoxin Ren
Xiaoxin Ren
The U.S. Department of Energy's Office of Scientific and Technical Information

16 August 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Fu-Jen WangFu-Jen Wang
Fu-Jen Wang
KKKusnandar Kusnandar
Kusnandar Kusnandar
HLHungwen Lin
Hungwen Lin
MTMinghua Tsai
Minghua Tsai
With the cost of energy rising, the value of conservation grows. Interest in energy efficiency could be a sound investment or a necessary public policy. Heat pump systems provide economical alternatives of recovering heat from different sources for use in various applications. The objective of this study is to present the strategic approach on the energy efficient analysis of the water heating system retrofitted by applying a heat pump system in the dormitory of a university. Energy savings were determined by comparing field measurements of water consumption, water temperature and power consumption of the overall system before (electric resistance heating system) and after (heat pump heating system) the implementation of this project. Furthermore, the building energy simulation code (eQuest) has been applied to verify and predict the long-term energy consumption for both water heating systems. The results from energy modelling revealed the good agreement for energy simulation and field measurement data and the improvement of energy efficiency and energy savings could be achieved satisfactorily by retrofitting of a heat pump system. The energy conversion efficiency of hot water for energy consumption at 0.63 (Mcal/Mcal) could be achieved after the application of heat pump water heating system. It also presented the annual saving about USD 20,000 (NTD 600,000) for the dorm by using a heat pump heating system under the electrical billing rate of Taiwan.

9 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
IPIndra Permana
Indra Permana
Fu-Jen WangFu-Jen Wang
Fu-Jen Wang
HLHungwen Lin
Hungwen Lin
JSJohnwin Siew
Johnwin Siew
The airflow distribution for a large space, such as a conference hall, is quite challenging to achieve a good and uniform thermal distribution. In the recent study, insufficient quantitative knowledge has been provided, notably for the appropriate supply air temperature and air velocity for the conference hall environment. In this study, a full-scale conference hall was simulated extensively for an expo building in Taiwan. A total of nine experiment numbers were carried out with various supply air temperature and air velocity settings. Through the use of a CFD approach, this study seeks to identify the ideal parameters for a comfortable and acceptable airflow distribution and temperature, with an eye toward potential compromises with an energy-efficient approach. The results demonstrate that the temperature distribution ranges from 18 to 26 °C, indicating an acceptable indoor thermal environment, depending on the parameter settings. The best settings for providing a pleasant indoor thermal environment are with a supply air temperature and air velocity of 15 °C and 1 m/s, which can keep the PMV index between −0.5 and 0.5. Utilizing a greater temperature setting may save energy, but sufficient air velocity must be addressed in order to meet the indoor thermal conditions. Furthermore, a greater air velocity may generate more noise and disrupt the situation in the conference hall, so it must be selected specifically.