Negative-pressurized isolation rooms have been approved effectively and applied widely for infectious patients. However, the outbreak of COVID-19 has led to a huge demand for negative-pressurized isolation rooms. It is critical and essential to ensure infection control performance through best practice of ventilation systems and optimum airflow distribution within isolation rooms. This study investigates a retrofitting project of an isolation room to accommodate COVID-19 patients. The field measurement has been conducted to ensure the compliance with the design specification from the CDC of Taiwan. The pressure differentials between negative-pressurized isolation rooms and corridor areas should be at least 8 Pa, while the air change rate per hour (ACH) should be 8–12 times. Computational fluid dynamics (CFD) is applied to evaluate the ventilation performance and contamination control. Different layout arrangements of exhaust air have been proposed to enhance the ventilation performance for infection control. A simple projected air-jet curtain has been proposed in the simulation model to enhance extra protection of medical staff. The resulting ventilation control revealed that the contamination control can be improved through the minor adjustment of exhaust air arrangement and the application of an air-jet curtain.
With the cost of energy rising, the value of conservation grows. Interest in energy efficiency could be a sound investment or a necessary public policy. Heat pump systems provide economical alternatives of recovering heat from different sources for use in various applications. The objective of this study is to present the strategic approach on the energy efficient analysis of the water heating system retrofitted by applying a heat pump system in the dormitory of a university. Energy savings were determined by comparing field measurements of water consumption, water temperature and power consumption of the overall system before (electric resistance heating system) and after (heat pump heating system) the implementation of this project. Furthermore, the building energy simulation code (eQuest) has been applied to verify and predict the long-term energy consumption for both water heating systems. The results from energy modelling revealed the good agreement for energy simulation and field measurement data and the improvement of energy efficiency and energy savings could be achieved satisfactorily by retrofitting of a heat pump system. The energy conversion efficiency of hot water for energy consumption at 0.63 (Mcal/Mcal) could be achieved after the application of heat pump water heating system. It also presented the annual saving about USD 20,000 (NTD 600,000) for the dorm by using a heat pump heating system under the electrical billing rate of Taiwan.
The energy use intensity (EUI) of convenience stores was substantially higher than that of office buildings and hotels, due to a compact footprint but a high density of equipment yielded a higher EUI. As a result, it is critical to assess and maintain the state of the convenience store in order to obtain a lower EUI and reduce energy consumption. This study utilizes a convenience store to evaluate energy consumption and perform a CFD simulation to see how the environment influences by cold storage showcase (CSS) equipment. On the basis of field testing and on-site web-based monitoring data, a survey of baseline information through data collecting and energy benchmarking data has been provided and extensively examined. According to energy monitoring, the convenience store’s highest electricity use is 23,055 kWh in June, and the lowest power consumption is 15,216 kWh in February. The CFD simulation results revealed that the temperature near the CSS can be 3–5 °C lower than in other regions. The temperature nearby return air will be lower as a result of the low-temperature air impacts from CSS. The AC sensor detects that the environment has met the indoor requirements and performs the load reduction operation. After adjusting the AC temperature, it is discovered that the unit is unable to attain the appropriate temperature. Energy consumption can be reduced, resulting in more energy-efficient AC and CSS operations. Furthermore, the CSS’s cold air effect might be taken advantage of by raising the AC-2 temperature set point to generate energy savings.
The depletion of petroleum reserves makes the emergence of a variety of alternative energy, one of which is Biodiesel. Biodiesel is a fatty acid ester derived from vegetable oil or animal by transesterification or esterification reaction. The purpose of this study was conducted to determine the effect of the use of fuel mixture of biodiesel jelantah with heating 950C to power, torque and Sfc. The test is done by loading the lamp load from 200 - 3200 watt on variation of biodiesel fuel volume by 30%, 40% and 50%. The research method used is descriptive analysis where the result of research is described and described based on research result. From the test results resulted in the addition of biodiesel jelantah fuel effect on power, torque and Sfc generated diesel motor.