Arun Vishwanath

Arun Vishwanath

Auto-generated profile, based on publicly available information

Arun Vishwanath

IBM Research Australia

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in IEEE Transactions on Mobile Computing
Verified
Journal Article
Closed access
ASArunan Sivanathan
Arunan Sivanathan
HGHassan Habibi Gharakheili
Hassan Habibi Gharakheili
FLFranco Loi
Franco Loi
ARAdam Radford
Adam Radford
CWChamith Wijenayake
Chamith Wijenayake
VSVijay Sivaraman
Vijay Sivaraman
The Internet of Things (IoT) is being hailed as the next wave revolutionizing our society, and smart homes, enterprises, and cities are increasingly being equipped with IoT devices. Yet, operators of such smart environments may not even be fully aware of their IoT assets. In this paper, we address this challenge by developing a framework for IoT device classification using network traffic characteristics. First, we instrument a smart environment with 28 different IoT devices spanning cameras, lights, plugs, motion sensors and health-monitors. We collect and synthesize traffic traces from this infrastructure for a period of 6 months, a subset of which we release as open data for the community to use. Second, we present insights into the underlying network traffic characteristics using statistical attributes such as activity cycles, port numbers, signalling patterns and cipher suites. Third, we develop a multi-stage machine-learning-based classification algorithm and demonstrate its ability to identify specific IoT devices with over 99%. Finally, we discuss the trade-offs between cost, speed, and performance involved in deploying the classification framework in real-time. Our study paves the way for operators of smart environments to monitor their IoT assets for presence, functionality, and cyber-security without requiring any specialized devices or protocols.

7 February 2019 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
AVArun Vishwanath
Arun Vishwanath
VCVikas Chandan
Vikas Chandan
KSKumar Saurav
Kumar Saurav
The buildings sector is one of the largest energy consuming entities today, accounting for about 40% of global energy consumption. Alongside, electricity prices are increasing in several nations worldwide, putting pressure on facility managers to reduce the expense incurred in operating their buildings. In this paper, we focus on building HVAC (heating, ventilation, and air conditioning) and make the following contributions. First, inspired by the deployment of IoT in buildings, we propose a data driven gray box model for zone thermal dynamics and use it to develop an optimization framework for pre-cooling a building. The goal is to determine a pre-cooling strategy that not only shifts the peak air conditioning power to low electricity tariff regimes, but also reduces the peak power, energy consumption and electricity costs associated with cooling a building. Second, the optimal pre-cooling problem turns out to be non-linear. To enable ease of use of our framework in the real-world without undermining its efficacy, we develop a linearised version of the problem and show that it has comparable performance to the original formulation. Third, we quantify the benefits of the pre-cooling optimization framework by applying it to building management system data, across multiple days, obtained from a large office building in Australia. The evaluations reveal that optimal pre-cooling lowers the peak power, energy consumption and electricity costs for cooling the building by up to 30% while ensuring that the thermal comfort of the occupants is maintained. We conclude by describing two applications of the proposed optimization framework for use in developing countries. Our pre-cooling solution incurs no capital expense and permits facility managers to take decisions from a data driven point of view for improving the energy efficiency of their buildings.

30 July 2019 in IEEE Transactions on Sustainable Computing
Verified
Journal Article
Closed access
ZZZimu Zheng
Zimu Zheng
QCQiong Chen
Qiong Chen
Cheng FanCheng Fan
Cheng Fan
NGNan Guan
Nan Guan
AVArun Vishwanath
Arun Vishwanath
FLFangming Liu
Fangming Liu
It is well-known that the HVAC (heating, ventilation and air conditioning) dominates electricity consumption in commercial buildings. In this paper, we focus on one of the core problems in building operation, namely chiller sequencing to reduce HVAC electricity consumption. Our contributions are threefold. First, we make a case for why it is important to quantify the performance profile of a chiller, namely coefficient of performance (COP), at run-time, by developing a data-driven COP estimation methodology. Second, we show that predicting COP accurately is a non-trivial problem, requiring considerable computation time. To overcome this barrier, we develop a data-driven COP prediction model and an edge-based chiller sequencing framework integrating the COP predictions, and show that they strike a good balance between electricity saving and ease of use for real-world deployment. Finally, we evaluate the performance of our scheme by applying it to real-world data, spanning 4 years, obtained from multiple chillers across 3 large commercial buildings in Hong Kong. The results show an electricity saving of over 30% compared to baselines. We offer our edge based data-driven chiller sequencing framework as a cost-effective and practical mechanism to reduce electricity consumption associated with HVAC operation in commercial buildings.

20 March 2024
Verified
Book Chapter
Closed access
PDF file
MLMinzhao Lyu
Minzhao Lyu
SMSharat Chandra Madanapalli
Sharat Chandra Madanapalli
AVArun Vishwanath
Arun Vishwanath
VSVijay Sivaraman
Vijay Sivaraman

29 November 2016 in IEEE/ACM Transactions on Networking
Verified
Journal Article
Closed access
HGHassan Habibi Gharakheili
Hassan Habibi Gharakheili
VSVijay Sivaraman
Vijay Sivaraman
TMTim Moors
Tim Moors
AVArun Vishwanath
Arun Vishwanath
JMJohn Matthews
John Matthews
CRChristopher J. Russell
Christopher J. Russell
Residential broadband consumption is growing rapidly, increasing the gap between Internet service provider (ISP) costs and revenues. Meanwhile, proliferation of Internet-enabled devices is congesting access networks, degrading end-user experience, and affecting content provider monetization. In this paper, we propose a new model whereby the content provider explicitly signals fast- and slow-lane requirements to the ISP on a per-flow basis, using open APIs supported through software defined networking (SDN). Our first contribution is to develop an architecture that supports this model, presenting arguments on why this benefits consumers (better user experience), ISPs (two-sided revenue), and content providers (fine-grained control over peering arrangement). Our second contribution is to evaluate our proposal using a real trace of over 10 million flows to show that video flow quality degradation can be nearly eliminated by the use of dynamic fast-lanes, and web-page load times can be hugely improved by the use of slow-lanes for bulk transfers. Our third contribution is to develop a fully functional prototype of our system using open-source SDN components (Openflow switches and POX controller modules) and instrumented video/file-transfer servers to demonstrate the feasibility and performance benefits of our approach. Our proposal is a first step towards the long-term goal of realizing open and agile access network service quality management that is acceptable to users, ISPs, and content providers alike.

12 June 2020
Verified
Conference Paper
Open access
MTMin Tian
Min Tian
AVArun Vishwanath
Arun Vishwanath
GVGuru Venkataramani
Guru Venkataramani
SSSuresh Subramaniam
Suresh Subramaniam
Cost of data centers has risen sharply in the past few years. Today, it represents about 3% of total US energy consumption with projections to increase further in the coming years. In this paper, we focus on the server infrastructure and observe that workload consolidation techniques, which maximize power efficiency of server systems, do not automatically optimize the overall system power efficiency especially when compute engines and the corresponding on-board cooling systems are considered holistically. We design SpinSmart, a framework that explores optimal server fan speeds to minimize the overall system energy consumption. We explore core capping strategies that estimate the desired number of CPU cores to be used at any given time to minimize combined CPU+fan power. Our experimental results show that we are able to achieve 1) energy savings of up to 10% of total energy and 80% of cooling energy when compared to workload consolidation without core capping strategy; 2) cooling energy savings up to 42% when compared to the strategy that randomly assigns jobs to all the servers and cores.