Huang Gao

Huang Gao

Auto-generated profile, based on publicly available information

Huang Gao

State Key Lab of Material Processing and Die & Mold Technology Huazhong University of Science and Technology Wuhan China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2024 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
SYShengrui Yu
Shengrui Yu
SSSenzhen Song
Senzhen Song
HGHuang Gao
Huang Gao
KWKai Wang
Kai Wang
LXLei Xu
Lei Xu
HZHuamin Zhou
Huamin Zhou

13 July 2021 in Asian Journal of Chemical Sciences
Verified
Journal Article
Open access
PDF file
KSKe Su
Ke Su
GXGuoqiang Xiang
Guoqiang Xiang
YZYunlong Zhang
Yunlong Zhang
XWXin Wang
Xin Wang
LWLinhui Wang
Linhui Wang
GHGao Huang
Gao Huang
In this study, a rapid and sensitive analytical method has been developed to detect tetracycline hydrochloride (TC) using manganese-doped carbon dots (Mn-CDs) prepared by one-step hydrothermal procedure using 1-(2-pyridinylazo)-2-naohthalenol (PAN) and MnCl2 as precursor reagents. The obtained Mn-CDs showed an ultraviolet emission at 360 nm with an excitation wavelength of 300 nm. TC has a strong characteristic absorption peak at 356 nm, which has a large spectral overlap with the emission band of the Mn-CDs. The fluorescence intensity (FI) of Mn-CDs at 360 nm is linearly quenched within the TC concentration range of 0.1-200 µM. The developed assay for the detection of TC was based on an inner filter effect (IFE) mechanism and is rapid, sensitive, and was successfully applied for the determination of TC in different poultry meat samples with satisfactory results.

8 June 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
JXJun Xie
Jun Xie
XCXiaoxu Cao
Xiaoxu Cao
HGHuang Gao
Huang Gao
HZHangchao Zhou
Hangchao Zhou
Peng ZhaoPeng Zhao
Peng Zhao
Jiquan LiJiquan Li
Jiquan Li
To overcome the shortcomings of existing magnetic levitation density measurement methods, such as a narrow measurement range (0.8~2.3 g/cm³) and cumbersome operation when expanding their measurement range, a novel density measurement method for high-density diamagnetic substances is proposed. In this method, the high-density substance is placed on an adjustable inclined plate, and both are positioned in a horizontally placed magnetic levitation device. By adjusting the angle of the inclined plate, the sample can achieve levitation in the device under the combined action of gravity, buoyancy, normal force, and magnetic force. Based on the analysis of the forces on the substance in the paramagnetic solution, the distance between the substance and the center of the left magnet surface as well as the angle of the inclined plate are measured, and a correlation function among the distance, angle, and density is established. Accurate measurement of the density of high-density substances is achieved based on this functional relationship. Meanwhile, this function provides three measurement modes, namely linear, non-linear, and arbitrary-position methods, to cope with different density measurement scenarios, and finally a comprehensive surface graph of measurable density is obtained. Experimental results show that this method can measure the density of small-volume high-density samples (such as copper, tin, zirconia ceramic, aluminum, and glass). It achieves an expanded measurement range and more straightforward operation.