Chunzhuo Wang

Chunzhuo Wang

Auto-generated profile, based on publicly available information

Chunzhuo Wang

Department of Electrical Engineering (ESAT), KU Leuven, 3000 Leuven, Belgium

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CWChunzhuo Wang
Chunzhuo Wang
TKT. Sunil Kumar
T. Sunil Kumar
WRWalter De Raedt
Walter De Raedt
GCGuido Camps
Guido Camps
HHHans Hallez
Hans Hallez
Bart VanrumsteBart Vanrumste
Bart Vanrumste
Unhealthy dietary habits are considered as the primary cause of various chronic diseases, including obesity and diabetes. The automatic food intake monitoring system has the potential to improve the quality of life (QoL) of people with diet-related diseases through dietary assessment. In this work, we propose a novel contactless radar-based approach for food intake monitoring. Specifically, a Frequency Modulated Continuous Wave (FMCW) radar sensor is employed to recognize fine-grained eating and drinking gestures. The fine-grained eating/drinking gesture contains a series of movements from raising the hand to the mouth until putting away the hand from the mouth. A 3D temporal convolutional network with self-attention (3D-TCN-Att) is developed to detect and segment eating and drinking gestures in meal sessions by processing the Range-Doppler Cube (RD Cube). Unlike previous radar-based research, this work collects data in continuous meal sessions (more realistic scenarios). We create a public dataset comprising 70 meal sessions (4,132 eating gestures and 893 drinking gestures) from 70 participants with a total duration of 1,155 minutes. Four eating styles (fork & knife, chopsticks, spoon, hand) are included in this dataset. To validate the performance of the proposed approach, seven-fold cross-validation method is applied. The 3D-TCN-Att model achieves a segmental F1-score of 0.896 and 0.868 for eating and drinking gestures, respectively. The results of the proposed approach indicate the feasibility of using radar for fine-grained eating and drinking gesture detection and segmentation in meal sessions.

11 July 2022 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Verified
Conference Paper
Open access
CWChunzhuo Wang
Chunzhuo Wang
TKT. Sunil Kumar
T. Sunil Kumar
WRWalter De Raedt
Walter De Raedt
GCGuido Camps
Guido Camps
HHHans Hallez
Hans Hallez
Bart VanrumsteBart Vanrumste
Bart Vanrumste
Maintaining adequate hydration is important for health. Inadequate liquid intake can cause dehydration problems. Despite the increasing development of liquid intake monitoring, there are still open challenges in drinking detection under free-living conditions. This paper proposes an automatic liquid intake monitoring system comprised of wrist-worn Inertial Measurement Units (IMU s) to recognize drinking gesture in free-living environments. We build an end-to-end approach for drinking gesture detection by employing a novel multi-stage temporal convolutional network (MS-TCN). Two datasets are collected in this research, one contains 8.9 hours data from 13 participants in semi-controlled environments, the other one contains 45.2 hours data from 7 participants in free-living environments. The Leave-One-Subject-Out (LOSO) evaluation shows that this method achieves a segmental F1-score of 0.943 and 0.900 in the semi-controlled and free-living datasets, respectively. The results also indicate that our approach outperforms the convolutional neural network and long-short-term-memory network combined model (CNN-LSTM) on our datasets. The dataset used in this paper is available at https://github.com/Pituohai/drinking-gesture-dataset/. Clinical Relevance- This automatic liquid intake monitoring system can detect drinking gesture in daily life. It has the potential to be used to record the frequency of drinking water for at-risk elderly or patients in the hospital

3 July 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CWChunzhuo Wang
Chunzhuo Wang
TKT. Sunil Kumar
T. Sunil Kumar
WRWalter De Raedt
Walter De Raedt
GCGuido Camps
Guido Camps
HHHans Hallez
Hans Hallez
Bart VanrumsteBart Vanrumste
Bart Vanrumste
Eating speed is an important indicator that has been widely investigated in nutritional studies. The relationship between eating speed and several intake-related problems such as obesity, diabetes, and oral health has received increased attention from researchers. However, existing studies mainly use self-reported questionnaires to obtain participants' eating speed, where they choose options from slow, medium, and fast. Such a non-quantitative method is highly subjective and coarse at the individual level. This study integrates two classical tasks in automated food intake monitoring domain: bite detection and eating episode detection, to advance eating speed measurement in near-free-living environments automatically and objectively. Specifically, a temporal convolutional network combined with a multi-head attention module (TCN-MHA) is developed to detect bites (including eating and drinking gestures) from IMU data. The predicted bite sequences are then clustered into eating episodes. Eating speed is calculated by using the time taken to finish the eating episode to divide the number of bites. To validate the proposed approach on eating speed measurement, a 7-fold cross validation is applied to the self-collected fine-annotated full-day-I (FD-I) dataset, and a holdout experiment is conducted on the full-day-II (FD-II) dataset. The two datasets are collected from 61 participants with a total duration of 513 h, which are publicly available. Experimental results show that the proposed approach achieves a mean absolute percentage error (MAPE) of 0.110 and 0.146 in the FD-I and FD-II datasets, respectively, showcasing the feasibility of automated eating speed measurement in near-free-living environments.

19 September 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CWChunzhuo Wang
Chunzhuo Wang
GMGert Mertes
Gert Mertes
KKKonstantinos Kyritsis
Konstantinos Kyritsis
LDLi Ding
Li Ding
WRWalter De Raedt
Walter De Raedt
Bart VanrumsteBart Vanrumste
Bart Vanrumste
Obesity and malnutrition have psychological and physiological impacts on the health of older adults. Automated eating gesture detection has the potential to advance the assessment of their dietary intake activity. However, detecting eating gestures in older adults poses heightened challenges due to the variability in their eating behaviors. Some individuals exhibit slower eating habits, while others experience limitations in using one hand. Conversely, certain individuals conform to typical eating patterns observed in the adult population. To address this issue, we propose an automated eating gesture detection system using wrist and head mounted inertial measurement unit (IMU) sensors. An end-to-end approach is developed to detect and segment the time interval of eating gestures by employing a multi-stage temporal convolutional network (MS-TCN). Compared to existing eating gesture detection approaches, the present method is able to segment intervals of detected eating gestures more efficiently. We assess our methodology using one self-collected dataset containing 24 older adults, along with three publicly available datasets: FIC, OREBA, and Clemson. The leave-one-subject-out (LOSO) evaluation shows that our method achieves a segmental F1-score of 0.944 on our dataset. Furthermore, results on the FIC, OREBA, and Clemson datasets consistently indicate that our detection approach outperforms existing sliding window-based algorithms that combine convolutional neural networks and recurrent neural networks (CNN-RNNs).

24 December 2024 in JMIR Nursing
Verified
Journal Article
Open access
HSHannelore Strauven
Hannelore Strauven
CWChunzhuo Wang
Chunzhuo Wang
HHHans Hallez
Hans Hallez
VAVero Vanden Abeele
Vero Vanden Abeele
Bart VanrumsteBart Vanrumste
Bart Vanrumste
Background: The rising prevalence of urinary incontinence (UI) among older adults, particularly those living in nursing homes (NHs), underscores the need for innovative continence care solutions. The implementation of an unobtrusive sensor system may support nighttime monitoring of NH residents’ movements and, more specifically, the agitation possibly associated with voiding events. Objective: This study aims to explore the application of an unobtrusive sensor system to monitor nighttime movement, integrated into a care bed with accelerometer sensors connected to a pressure-redistributing care mattress. Methods: A total of 6 participants followed a 7-step protocol. The obtained dataset was segmented into 20-second windows with a 50% overlap. Each window was labeled with 1 of the 4 chosen activity classes: in bed, agitation, turn, and out of bed. A total of 1416 features were selected and analyzed with an XGBoost algorithm. At last, the model was validated using leave one subject out cross-validation (LOSOCV). Results: The trained model attained a trustworthy overall F1-score of 79.56% for all classes and, more specifically, an F1-score of 79.67% for the class “Agitation.” Conclusions: The results from this study provide promising insights in unobtrusive nighttime movement monitoring. The study underscores the potential to enhance the quality of care for NH residents through a machine learning model based on data from accelerometers connected to a viscoelastic care mattress, thereby driving progress in the field of continence care and artificial intelligence–supported health care for older adults.

17 April 2026 in JMIR Public Health and Surveillance
Verified
Journal Article
Open access
ACAmsalu Tomas Chuma
Amsalu Tomas Chuma
DKDesalew Mekonnen Kassie
Desalew Mekonnen Kassie
JVJens-Uwe Voigt
Jens-Uwe Voigt
MAMelkamu Hunegnaw Asmare
Melkamu Hunegnaw Asmare
AYAhmed Saeed Youssef
Ahmed Saeed Youssef
Bart VanrumsteBart Vanrumste
Bart Vanrumste
Background: Rheumatic heart disease (RHD) is a sequela of recurrent, untreated group A Streptococcus infections. RHD disproportionately affects children and young adults in the Global South. Intermittent mass screening of early RHD by using affordable tools in these disease-endemic regions is essential for effective prevention. Objective: This study examined multimodal physiological data for assessing the prevalence of early RHD in a cohort of asymptomatic, at-risk students in rural Ethiopia. Methods: A total of 584 asymptomatic children aged 10 to 20 years were randomly selected for screening and stratified into 2 groups (≤14 and >14 years). Electrocardiogram, phonocardiogram, and echocardiography screening were performed, with diagnoses based on the 2012 World Heart Federation criteria. Results: After excluding 1.4% (8/584) of the children, who had nonrheumatic findings, 576 participants were analyzed, including 334 (58.0%) female and 242 (42.0%) male children. The mean age was 16.1 (SD 2.4) years (95% CI 15.9-16.3). Echocardiographic screening identified 19 cases of RHD (n=10, 52.6% borderline and n=9, 47.4% definite). Female children accounted for 68.4% (13/19) of cases, and the association between female sex and RHD was not statistically significant (odds ratio 1.59, 95% CI 0.60-4.25; P=.35). The estimated prevalence of RHD was 32.5 per 1000 population (95% CI 18.1-46.9; SE 7.4; 19/576, 3.3%), which was significantly higher than the most recent multicenter prevalence estimate of 19 per 1000 population (95% CI 13.9-23.4; odds ratio 2.12; P=.03). Mitral regurgitation was the predominant lesion (16/19, 84.2%), followed by mitral stenosis (2/19, 10.5%) and aortic regurgitation (1/19, 5.3%). Phonocardiogram analysis showed mitral regurgitation (10/19, 52.6%), mitral stenosis (2/19, 10.5%), and subclinical findings in the rest of patients with RHD. Prolonged PR intervals were observed in 10.5% (2/19) of the RHD-positive participants. Conclusions: This study confirms persistent high prevalence of asymptomatic RHD among students in rural regions of Ethiopia. Although there was a female predominance in RHD incidence, the difference between the sexes was not statistically significant.