The closed-vessel conductively heated digestion system (CHDS) was evaluated to digest dry dog foods for further determination of K, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The CHDS method was optimized using a fractional factorial design with five variables (HNO3 concentration, H2O2 volume, temperature, holding time, and pre-digestion time) at two levels. The accuracy of the CHDS procedure was checked by the analysis of reference materials from the National Institute of Standards and Technology (NIST SRM 1577b Bovine Liver and 2976 Mussel Tissue) and Brazilian Agricultural Research Corporation (Embrapa MR-E1002A Fish Food). Also, the digestion efficiencies were calculated from residual carbon contents (RCCs). The RCC and blank values in the CHDS digested samples were consistently low, which is suitable for determinations using ICP OES and ICP-MS techniques. For comparison, all samples were also digested by microwave-assisted digestion in closed vessels (MW-AD). Results for Na, K, Cu, Fe, Mn, and Zn determined in sample digests obtained by CHDS were not statistically different at a 95% confidence level from those observed for MW-AD. Limits of quantification (LOQ) calculated from digests in CHDS and MW-AD were comparable, and the values provided adequate limits for elemental determinations in dog foods. Data from mineral composition and moisture were employed in a clustering analysis (HCA) and the discrimination of the samples among different manufacturers and food for dogs at different life stages was possible.
4 November 2026 in Journal of Analytical Atomic Spectrometry
A low-cost disposable PLA platform fabricated by 3D printing provides accurate determination of Pd, Pt and Ru in cancer cells by HR-CS GF AAS while reducing dependence on conventional graphite platforms.
1 April 2026 in Brazilian Journal of Analytical Chemistry
A conductively-heated digestion system (CHDS) with closed-vessel and diluted acid was evaluated for the preparation of animal feed for subsequent determination of As, Cd, Mo, Ni, Pb, Se and V by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The analytical performance of the digestor was checked by analyzing fish tissue, tuna and corn bran certified reference materials (CRMs) using 1 mL of 30% (w w-1) hydrogen peroxide plus 2 mL of nitric acid at 14, 7 and 3.5 mol L-1 HNO3. The recoveries of analytes in CRMs digested at different acid concentrations varied from 80 – 116% (3.5 mol L⁻¹ HNO₃) 86 – 118% (7 mol L⁻¹ HNO₃) e 80 – 123% (14 mol L⁻¹ HNO₃). The method was applied to real animal feed samples, and the CHDS results were like those of comparative microwave digestion (MWD). Quantification limits of analytes found by CHDS and MWD were also similar, concerning different acid concentrations. However, the use of diluted nitric acid in the preparation of animal feed samples proved to be a viable and efficient approach, allowing lower residual acidity, reduction in reagent consumption and acid waste generation, in accordance with the principles of Green Chemistry.