Key Laboratory of Control of Power Transmission and Conversion, School of Electronics, Information, and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
Auto-generated profile, based on publicly available information
Ruogu Yao
Key Laboratory of Control of Power Transmission and Conversion, School of Electronics, Information, and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
Active power decoupling (APD) circuits are frequently employed to suppress dc-side second harmonic of single-phase inverters. Triangular current mode (TCM) control enables the realization of zero-voltage switching. However, due to the considerable current ripple and variable switching frequency under TCM modulation, it is quite difficult to accurately detect, sample and control the inductor current. In this article, based on a buck APD circuit under TCM modulation, a voltage closed-loop control strategy combined with time prediction method is proposed, which eliminates the need to sample the dc bus current and the decoupling inductor current. The approach achieves effective harmonic suppression and full-range soft switching with easy control. In addition, the effect of turning off the APD circuit for a short period of time on switching frequency and harmonic suppression is explored. The proposed strategy is validated on a 600 W experimental prototype.
12 September 2025 in IEEE Transactions on Power Electronics
Single-phase full-bridge inverter operating in triangular current mode (TCM) can realize zero-voltage switching to achieve high efficiency. However, the TCM full-bridge inverter features a wide range of switching frequency variation, especially near the ac current zero-crossing point (ZCP), which increases the switching loss and control difficulty. In this article, an adaptive optimal quasi-trapezoidal current mode (QTCM) control strategy is proposed based on the output characteristics of the full-bridge inverter, which reduces the switching frequency and inductor current rms by adjusting the durations of the different operating modes. The relationship between the zero level ratio m of the inverter output and the switching frequency and the peak inductor current is established. By adjusting the ratio m, co-optimization of switching frequency and conduction loss is implemented according to the output voltage and current. The switching sequence of the power switches is improved to achieve the seamless switching of the ac current ZCP. A 1-kW prototype with Gallium nitride (GaN) devices is built to verify the effectiveness of proposed modulation strategy with a peak efficiency of 98.3%. Compared with TCM, the proposed QTCM has a higher efficiency over the whole load range with the same hardware cost.