Valentin Oreiller

Valentin Oreiller

Auto-generated profile, based on publicly available information

Valentin Oreiller

Institute of Informatics, School of Management, HES-SO Valais-Wallis, Sierre, Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Medical Image Analysis
Verified
Journal Article
Open access
VOValentin Oreiller
Valentin Oreiller
VAVincent Andrearczyk
Vincent Andrearczyk
MJMario Jreige
Mario Jreige
SBSarah Boughdad
Sarah Boughdad
HEHesham Elhalawani
Hesham Elhalawani
ADAdrien Depeursinge
Adrien Depeursinge
This paper relates the post-analysis of the first edition of the HEad and neCK TumOR (HECKTOR) challenge. This challenge was held as a satellite event of the 23rd International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI) 2020, and was the first of its kind focusing on lesion segmentation in combined FDG-PET and CT image modalities. The challenge's task is the automatic segmentation of the Gross Tumor Volume (GTV) of Head and Neck (H&N) oropharyngeal primary tumors in FDG-PET/CT images. To this end, the participants were given a training set of 201 cases from four different centers and their methods were tested on a held-out set of 53 cases from a fifth center. The methods were ranked according to the Dice Score Coefficient (DSC) averaged across all test cases. An additional inter-observer agreement study was organized to assess the difficulty of the task from a human perspective. 64 teams registered to the challenge, among which 10 provided a paper detailing their approach. The best method obtained an average DSC of 0.7591, showing a large improvement over our proposed baseline method and the inter-observer agreement, associated with DSCs of 0.6610 and 0.61, respectively. The automatic methods proved to successfully leverage the wealth of metabolic and structural properties of combined PET and CT modalities, significantly outperforming human inter-observer agreement level, semi-automatic thresholding based on PET images as well as other single modality-based methods. This promising performance is one step forward towards large-scale radiomics studies in H&N cancer, obviating the need for error-prone and time-consuming manual delineation of GTVs.

22 March 2023 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
DADaniel Abler
Daniel Abler
RSRoger Schaer
Roger Schaer
VOValentin Oreiller
Valentin Oreiller
HVHimanshu Verma
Himanshu Verma
JRJulien Reichenbach
Julien Reichenbach
ADAdrien Depeursinge
Adrien Depeursinge
Background: Radiomics, the field of image-based computational medical biomarker research, has experienced rapid growth over the past decade due to its potential to revolutionize the development of personalized decision support models. However, despite its research momentum and important advances toward methodological standardization, the translation of radiomics prediction models into clinical practice only progresses slowly. The lack of physicians leading the development of radiomics models and insufficient integration of radiomics tools in the clinical workflow contributes to this slow uptake. Methods: We propose a physician-centered vision of radiomics research and derive minimal functional requirements for radiomics research software to support this vision. Free-to-access radiomics tools and frameworks were reviewed to identify best practices and reveal the shortcomings of existing software solutions to optimally support physician-driven radiomics research in a clinical environment. Results: Support for user-friendly development and evaluation of radiomics prediction models via machine learning was found to be missing in most tools. QuantImage v2 (QI2) was designed and implemented to address these shortcomings. QI2 relies on well-established existing tools and open-source libraries to realize and concretely demonstrate the potential of a one-stop tool for physician-driven radiomics research. It provides web-based access to cohort management, feature extraction, and visualization and supports “no-code” development and evaluation of machine learning models against patient-specific outcome data. Conclusions: QI2 fills a gap in the radiomics software landscape by enabling “no-code” radiomics research, including model validation, in a clinical environment. Further information about QI2, a public instance of the system, and its source code is available at https://medgift.github.io/quantimage-v2-info/. Key points As domain experts, physicians play a key role in the development of radiomics models. Existing software solutions do not support physician-driven research optimally. QuantImage v2 implements a physician-centered vision for radiomics research. QuantImage v2 is a web-based, “no-code” radiomics research platform.

29 October 2022 in European Journal of Hybrid Imaging
Verified
Journal Article
Open access
PDF file
DFDaphn&Eacute Faist
Daphn&Eacute Faist
MJMario Jreige
Mario Jreige
VOValentin Oreiller
Valentin Oreiller
MLMarie Nicod Lalonde
Marie Nicod Lalonde
NSNiklaus Schaefer
Niklaus Schaefer
John PriorJohn Prior
John Prior
Background Quality and reproducibility of radiomics studies are essential requirements for the standardisation of radiomics models. As recent data-driven respiratory gating (DDG) [F-18]-FDG has shown superior diagnostic performance in lung cancer, we evaluated the impact of DDG on the reproducibility of radiomics features derived from [F-18]-FDG PET/CT in comparison to free-breathing flow (FB) imaging. Methods Twenty four lung nodules from 20 patients were delineated. Radiomics features were derived on FB flow PET/CT and on the corresponding DDG reconstruction using the QuantImage v2 platform. Lin's concordance factor (C-b) and the mean difference percentage (DIFF%) were calculated for each radiomics feature using the delineated nodules which were also classified by anatomical localisation and volume. Non-reproducible radiomics features were defined as having a bias correction factor C-b < 0.8 and/or a mean difference percentage DIFF% > 10. Results In total 141 features were computed on each concordance analysis, 10 of which were non-reproducible on all pulmonary lesions. Those were first-order features from Laplacian of Gaussian (LoG)-filtered images (sigma = 1 mm): Energy, Kurtosis, Minimum, Range, Root Mean Squared, Skewness and Variance; Texture features from Gray Level Cooccurence Matrix (GLCM): Cluster Prominence and Difference Variance; First-order Standardised Uptake Value (SUV) feature: Kurtosis. Pulmonary lesions located in the superior lobes had only stable radiomics features, the ones from the lower parts had 25 non-reproducible radiomics features. Pulmonary lesions with a greater size (defined as long axis length > median) showed a higher reproducibility (9 non-reproducible features) than smaller ones (20 non-reproducible features). Conclusion Calculated on all pulmonary lesions, 131 out of 141 radiomics features can be used interchangeably between DDG and FB PET/CT acquisitions. Radiomics features derived from pulmonary lesions located inferior to the superior lobes are subject to greater variability as well as pulmonary lesions of smaller size.

1 February 2022 in Clinical and Translational Radiation Oncology
Verified
Journal Article
Open access
PFPierre Fontaine
Pierre Fontaine
VAVincent Andrearczyk
Vincent Andrearczyk
VOValentin Oreiller
Valentin Oreiller
DADaniel Abler
Daniel Abler
JCJoel Castelli
Joel Castelli
ADAdrien Depeursinge
Adrien Depeursinge
• PET images features are more stable across different delineation of the same target. • Shape family features are more stable. • The survival model based on Dedicated contours achieved better performance for predicting PFS.

15 July 2022
Verified
Book Chapter
Closed access
PDF file
DADaniel Abler
Daniel Abler
VAVincent Andrearczyk
Vincent Andrearczyk
VOValentin Oreiller
Valentin Oreiller
JGJavier Barranco Garcia
Javier Barranco Garcia
DVDiem Vuong
Diem Vuong
ADAdrien Depeursinge
Adrien Depeursinge

2 June 2020 in arXiv
Verified
Preprint
Open access
PDF file
VOValentin Oreiller
Valentin Oreiller
VAVincent Andrearczyk
Vincent Andrearczyk
JFJulien Fageot
Julien Fageot
John PriorJohn Prior
John Prior
ADAdrien Depeursinge
Adrien Depeursinge
Locally Rotation Invariant (LRI) operators have shown great potential in biomedical texture analysis where patterns appear at random positions and orientations. LRI operators can be obtained by computing the responses to the discrete rotation of local descriptors, such as Local Binary Patterns (LBP) or the Scale Invariant Feature Transform (SIFT). Other strategies achieve this invariance using Laplacian of Gaussian or steerable wavelets for instance, preventing the introduction of sampling errors during the discretization of the rotations. In this work, we obtain LRI operators via the local projection of the image on the spherical harmonics basis, followed by the computation of the bispectrum, which shares and extends the invariance properties of the spectrum. We investigate the benefits of using the bispectrum over the spectrum in the design of a LRI layer embedded in a shallow Convolutional Neural Network (CNN) for 3D image analysis. The performance of each design is evaluated on two datasets and compared against a standard 3D CNN. The first dataset is made of 3D volumes composed of synthetically generated rotated patterns, while the second contains malignant and benign pulmonary nodules in Computed Tomography (CT) images. The results indicate that bispectrum CNNs allows for a significantly better characterization of 3D textures than both the spectral and standard CNN. In addition, it can efficiently learn with fewer training examples and trainable parameters when compared to a standard convolutional layer.