5 September 2018 in Journal of Bone and Joint Surgery
Background: Guidelines recommend both histological analysis and culture for definite diagnosis of osteomyelitis. It is not clear if histological and culture criteria can be used interchangeably in the clinical scenario of toe amputation. We therefore prospectively compared the results of intraoperative culture and those of histological examination in this setting.Methods: Consecutive patients requiring toe or forefoot amputation at the University Hospital Basel during a 2-year period were included in the study. Biopsy specimens from the residual bone were cultured according to microbiological standards. Histological analysis was performed using standardized criteria for osteomyelitis. Clinical outcomes were assessed retrospectively via chart review.Results: Of 51 patients included in the study, 33 (65%) had a positive culture of residual bone and 14 (27%) showed histological signs of osteomyelitis. A negative histological result but a positive culture was found for 21 (41%) of the patients, suggesting that culture has a high false-positive rate if histological analysis is used as the reference to rule out osteomyelitis. The recommended criteria of both positive histological findings and positive culture were fulfilled by 12 (24%) of the 51 patients.Conclusions: Positive cultures of residual bone after forefoot or toe amputation overestimate the true rate of osteomyelitis as defined by histological analysis, presumably because of contamination from soft tissue at the time of surgery. Additional studies are needed to evaluate the indications for, and the duration of, antibiotic treatment according to these findings.Clinical Relevance: Our results cast doubt on the strategy of relying solely on culture of bone biopsy specimens when deciding whether antibiotic treatment for osteomyelitis is necessary after toe or forefoot amputation.
5 April 2016 in SAE International Journal of Advances and Current Practices in Mobility
The tightening pollutant emission limits require the use of active aftertreatment methods for NOx and particulate matter (PM). Diesel particulate filter (DPF) is a part of commercial aftertreatment system (ATS). PM accumulated in DPF is continuously passively or periodically actively regenerated with the assistance of efficient diesel oxidation catalysts (DOC) having a high efficiency and durability in hydrocarbon (HC), NO and CO oxidation reactions. A high HC concentration during fuel feeding in active regeneration is demanding for DOC. The deactivation in air, hydrothermal, sulfation and active regeneration conditions were evaluated with platinum (Pt-) and platinum-palladium (PtPd)-DOCs by laboratory simulations using the ageing temperature and time as primary variables. The oxidizing conditions with a high oxygen concentration without HCs were deactivating DOCs clearly more than active regeneration conditions with a low oxygen and high HC concentration at 700-800°C. It was found a correlation to between rapid aged laboratory samples and a DOC field-aged for 2000 hours in an actively regenerated DOC+DPF system. These rapid ageing principles with a confirmed correlation can be applied for the development of real applications.The addition of a small amount of Pd on Pt-DOC (Pt → Pt:Pd = 4:1, 2:1) improved significantly the HC oxidation efficiency of aged DOC in the active regeneration with high HC feed concentration (C1 0.6-1.2%). In normal diesel exhaust with a low HC concentration (500 ppm C1), Pt-only was still slightly better as sulfated. It was concluded that the role of Pd on the PtPd-DOC performance in active regeneration conditions is more the promotion in high HC feed conditions than the thermal stabilization. The oxidation selectivity of various diesel HCs (propene, propane, toluene, decane) was also analyzed on Pt- and PtPd-DOCs. In addition, active regeneration with fuel injection and higher temperatures was able to regenerate the sulfated Pt- and PtPd-DOCs.
1 May 2021 in British Journal of Surgery
Objective: Percutaneous ultrasound-guided creation of an arteriovenous fistula (pAVF) for hemodialysis access is a relatively novel procedure with promising technical success and patency rates. The vascular surgery departments of two collaborating Swiss hospitals had decided to introduce the technique to their services. A surgeon experienced in the technique (AM) was supposed to come to Switzerland and proctor the first four procedures. Due to the SARS-CoV-2 pandemic and travel restrictions, this was not possible and we decided to perform the first four pAVF procedures tele-proctored via a video conference system. We present the setup and our experience with tele-proctoring. Methods: The setup relied on an all-in-one live video production device, video encoder, video streamer and video recorder (Pearl-2, Epiphan), which made it possible to simultaneously transmit the live image from the ultrasound device (GE Logiq S8, linear probe 9L-D) and a live image from a video camera (JVC Camcorder G/-HM440E, Japan), both connected via HDMI (Figure). The live stream was shared with the proctor in France and the device support team in the US, using an encrypted Swiss video client (www.vitimway.ch). The setup was tested with all parties three days in advance. Results: All 4 procedures started with a verbal briefing and a live ultrasound scan. All steps of the procedures were taken under the proctor’s instruction and supervision. The proctor gave on average 21 instructions per procedure. An average 4 were device-related but these became less frequent as we proceeded. The operators consulted the proctor on average 5 times per procedure. The average duration of the procedure was 34 min. The pAVF creation was successful in all 4 patients, with an average fistula flow measured at the end of the procedure of 600 ml/min. Conclusion: Our experience showed us that pAVF creation, which is a procedure performed entirely under sonographic guidance lends itself particularly well to tele-proctoring. The simultaneous transmission of the live sonographic image and the live image of the operators' hands allowed the proctor to supervise and correct the key steps of the procedures. The simplicity of the set-up and the quality of proctor-operator interaction was such a positive experience that we can well envisage a much wider use of tele-proctoring in the future.
1 May 2021 in British Journal of Surgery
Percutaneous creation of arteriovenous fistulae (pAVF) has been developed as an alternative to the creation of an upper arm cephalic or basilic vein fistula. Several studies have shown high technical success rates and comparable time of maturation. To our knowledge, the technique has not been used in Switzerland before. Prospective data collection of the first consecutive patients undergoing the creation of pAVF between April and July 2020 at two vascular surgery centres. Seven patients underwent pAVF creation with the Ellipsys® vascular access system under regional anaesthesia for maximum vasodilation. The procedures were performed entirely under sonographic control without the use of fluoroscopy. The cephalic or basilic vein was punctured and the puncture needle advanced under sonographic control through the cubital perforator vein into the proximal radial artery. The Ellipsys® catheter was advanced over a guidewire and activated to create the fistula between the proximal radial artery and the perforator vein. The fistula was further dilated with a 5mm PTA balloon. We achieved technical success in 6 patients. In one patient with small and spastic vessels, the needle could not be advanced into the radial artery. A conventional upper arm cephalic fistula was created during the same procedure. In three patients primary maturation was achieved and the cephalic vein or distal basilic vein could be punctured for dialysis without any adjunct procedures. One patient required three additional procedures before the fistula could be used successfully (additional angioplasty of the fistula, superficialisation of the basilic vein and correction of a cubital vein stenosis by excision and end-to-end anastomosis). One patient required superficialisation of the basilic vein and one patient transposition of the arterialised brachial vein. Maturation was achieved in six pAVF after a mean of 158 days with a mean fistula flow of 920 ml/ min. We achieved high technical success and maturation rates in our first patients undergoing pAVF creation with the Ellipsys® system. Prerequisites are suitable anatomy of the cubital perforator vein and good skills in sonography and endovascular techniques. We believe that pAVF is a promising alternative to the creation of a conventional upper arm fistula in patients unsuitable for a distal radio-cephalic fistula.
10 April 2026 in BMC Nephrology
T(the Swiss Transplant Cohort Study (STCS)
the Swiss Transplant Cohort Study (STCS)
+9
The transplantation of a single kidney, while its partner kidney is discarded despite both having been initially offered (dual-offered, single-transplanted