Modeling an aortic dissection represents a particular challenge from a numerical perspective, especially when it comes to the interaction between solid (aortic wall) and liquid (blood flow). The complexity of patient‐specific simulations requires a variety of parameters, modeling assumptions and simplifications that currently hinder their routine use in clinical settings. We present a numerical framework that captures, among other things, the layer‐specific anisotropic properties of the aortic wall, the non‐Newtonian behavior of blood, patient‐specific geometry, and patient‐specific flow conditions. We compare hemodynamic indicators and stress measurements in simulations with increasingly complex material models for the vessel tissue ranging from rigid walls to anisotropic hyperelastic materials. We find that for the present geometry and boundary conditions, rigid wall simulations produce different results than fluid–structure interaction simulations. Considering anisotropic fiber contributions in the tissue model, stress measurements in the aortic wall differ, but shear stress‐based biomarkers are less affected. In summary, the increasing complexity of the tissue model enables capturing more details. However, an extensive parameter set is also required. Since the simulation results depend on these modeling choices, variations can lead to different recommendations in clinical applications.
14 October 2024 in IEEE Transactions on Biomedical Engineering
Aortic dissection leads to late complications due tochronic degeneration and dilatation of the false lumen. This study examines the interaction between hemodynamics and long-term remodeling of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using CT angiography. Fluid–structure interaction models with tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Aortic dilatation was most significant distal to the left subclavian artery, reaching 6 cm in the chronic phase. Simulations quantified the flow jet velocity through the entry tear, which peaked at 185 cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2 mmHg in the subacute and chronic phases, with wall shear stress reaching 4 Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8 mm as disease progressed, which was associated with an overall increase in aortic diameter. Simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5 mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.
13 September 2023 in Journal of The Royal Society Interface
In situ tissue engineering offers an innovative solution for replacement valves and grafts in cardiovascular medicine. In this approach, a scaffold, which can be obtained by polymer electrospinning, is implanted into the human body and then infiltrated by cells, eventually replacing the scaffold with native tissue. In silico simulations of the whole process in patient-specific models, including implantation, growth and degradation, are very attractive to study the factors that might influence the end result. In our research, we focused on the mechanical behaviour of the polymeric scaffold and its short-term response. Following a recently proposed constitutive model for the anisotropic inelastic behaviour of fibrous polymeric materials, we present here its numerical implementation in a finite element framework. The numerical model is developed as user material for commercial finite element software. The verification of the implementation is performed for elementary deformations. Furthermore, a parallel-plate test is proposed as a large-scale representative example, and the model is validated by comparison with experiments.
The placenta and uterus are essential to healthy human pregnancy, yet their complex adaptation and function remain difficult to study, particularly during the second trimester. Historical collections of placenta in situ specimens, including the Boyd, Dixon, and Carnegie Collections, provide rare access to placental and uterine anatomy across developmental stages and pathological conditions. Due to advancements in obstetric care, the preparation and extent of specimens in these collections is uncommon nowadays. They therefore offer a unique window into pregnancy that contemporary imaging cannot fully reproduce. This review article briefly summarizes these historical collections and examines how they can be integrated with modern imaging, machine learning, and multiscale modeling to extend their research utility. Advances in computational methods support the digitization and 3D reconstruction of 2D histological sections, helping to mitigate issues such as tissue deformation, staining variability, and missing sections. In addition, machine learning approaches enable automated segmentation, facilitating more detailed characterization of utero-placental structures and associated physiological functions. Image-based multiscale modeling can link microscale features, such as villous capillary architecture, to organ-scale responses including global perfusion and oxygen transport, while enabling efficient computation when enhanced with physics-informed neural networks or neural operators. These methods preserve the scientific value of legacy specimens while enabling new avenues for studying pregnancy complications such as preeclampsia and fetal growth restriction. By combining legacy resources with contemporary analytical techniques in an interdisciplinary framework, a more thorough understanding of placental biology and maternal-fetal health can be achieved that may inform future research and clinical applications.