Liushuai Zheng

Liushuai Zheng

Auto-generated profile, based on publicly available information

Liushuai Zheng

Department of Biomedical Engineering, City University of Hong Kong, Hong Kong

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2021 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
LZLiushuai Zheng
Liushuai Zheng
YJYuanjun Jia
Yuanjun Jia
DDDingran Dong
Dingran Dong
WLWahshing Lam
Wahshing Lam
DLDongfang Li
Dongfang Li
DSDong Sun
Dong Sun
Automatic 3D navigation control of microrobot in large microenvironment is one of the primary challenges hindering its applications. In this article, we present a systematic approach to use an electromagnetic manipulation system to deal with this challenge. Two movable orthogonal microscopic cameras scan the microenvironment on the top view and side view to build a stereo occupancy map automatically. The initial position of microrobot can be located on the basis of the similarity curves generated by the scanning sequences. In accordance with the distribution characteristic of electromagnetic fields in workspace, an enhanced rapidly exploring random tree algorithm is proposed to avoid obstacles in the complex environment. To ensure continuous visual servo in wide range, a field-of-view tracking method is developed using a specific image definition evaluation algorithm. A prescribed performance controller with disturbance observer is designed, which guarantees that the microrobot can remain in the view of microscopic cameras, and the transient and steady-state performance of the system can satisfy the expected requirements. A set of experiments are performed to verify the effectiveness of the proposed automatic 3D navigation strategy. Experimental results show that the microrobot can navigate automatically in a $\boldsymbol{12}\,\times 10\,\times \text{10-mm}$ microenvironment containing obstacles, and achieve reliable field-of-view tracking and path following at high speed.

20 July 2022 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
LZLiushuai Zheng
Liushuai Zheng
HJHaibo Ji
Haibo Ji
DSDong Sun
Dong Sun
Microswarms assembled by microparticles have shown promising prospects in targeted delivery. However, the automated manipulation of microswarms remains a considerable challenge due to the limitations of existing in vivo imaging technology. In this article, we design a magnetic tweezer system with a large workspace of 100 mm × 100 mm × 30 mm, which can assemble, transport, and disassemble microswarms efficiently. The magnetic tweezers generate rotating magnetic fields in the workspace, enabling magnetized microparticles to roll toward a specific point along spiral trajectories. The assembly process and mechanism of microswarms are analyzed. The developed system can assemble low-density magnetic microparticles to form a stable and compact microswarm at a predetermined position. Actuation of the magnetic tweezers allows precise navigation of the swarm without relying on real-time image feedback. The experimental results show that the flexible microswarm can achieve satisfactory motion performance and transmission efficiency. The microswarm can successfully move on a slope with an inclination angle of $40^\circ $ and navigate analog channels. The overall delivery efficiency can reach 92%.

30 August 2021 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
YJYuanjun Jia
Yuanjun Jia
LZLiushuai Zheng
Liushuai Zheng
DDDingran Dong
Dingran Dong
Kangkai GaoKangkai Gao
Kangkai Gao
DSDong Sun
Dong Sun
Navigation control of microrobots in vivo has great potential in precision medicine and has attracted considerable attention in recent years. The control performance of the existing methods is considerably affected by hysteresis nonlinearity. This article presents a robust control method that can overcome hysteresis influence in navigating a microrobot actuated by an electromagnetic coil system. A motion planner that combines the breadth-first search (BFS) method and genetic algorithm (GA) is used to plan a reliable and flexible trajectory for the microrobot navigation. To compensate for hysteresis nonlinearity existing in the system, the Prandtl–Ishlinskii (PI) model is introduced. A robust controller that integrates adaptive sliding mode control (ASMC) and nonlinear disturbance observer is designed to guarantee the stability and accuracy of the microrobot in motion. Experiments have been performed to demonstrate the effectiveness of the proposed approach. The success of this research will advance the microrobot navigation for in vivo applications. Note to Practitioners—The motivation of this article is to eliminate the effect of hysteresis caused by the electromagnetic system on microrobot motion. Existing research on hysteresis compensation mostly uses inverse model or online model identification, which is not suitable for real-time control of the microrobot. In addition, the disturbance and uncertainty caused by the microfluidic environment at different flow rates will also affect the control performance of the microrobot. To solve the above problems, an adaptive robust control method is developed in this article. Experimental results have shown that the proposed method can successfully control the microrobot in the in vitro and in vivo environment.

28 December 2021 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
DDDingran Dong
Dingran Dong
LXLiuxi Xing
Liuxi Xing
LZLiushuai Zheng
Liushuai Zheng
YJYuanjun Jia
Yuanjun Jia
DSDong Sun
Dong Sun
Manipulating microrobots to move in a 3-D space is a basic requirement for their in vivo medical applications. In this study, the automatic manipulation of a microrobot in a liquid 3-D space via an electromagnetic coil system is investigated. A path planner is designed to search an optimal path in a 3-D space with obstacles automatically, and a cascaded control algorithm is developed to control the microrobot’s movement along the planned path. The path is generated by combining the A-star and minimum jerk methods. The collision of the generated path with the obstacles is prevented and the hysteresis caused by the current change is minimized by reducing the jerk of the movement with a passable path from the starting point to the endpoint. In the cascaded control algorithm, the incremental nonlinear dynamic inversion (INDI) method and a proportional control are used as the inner and outer loops to guide the microrobot’s movement along the desired trajectory with an appropriate velocity while eliminating the influence of system uncertainty and external disturbances. Simulation and experiments are performed to verify the effectiveness of the proposed control strategy.

27 January 2025 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
FPFei Pan
Fei Pan
SCShuxun Chen
Shuxun Chen
LZLiushuai Zheng
Liushuai Zheng
SZShaohua Zhi
Shaohua Zhi
XCXi Chen
Xi Chen
DSDong Sun
Dong Sun
This paper proposes a practical micropipette-image (2-D pixel and 3-D spatial coordination) calibration method indispensable to somatic cell microinjection, leveraging advancements in modern motorized micromanipulators. The method determines the depth information of the micropipette in the microscope field by assessing the contact between the micropipette tip and the bottom of the culture dish. It uses recoverable deformation upon contact as a criterion for precise positioning, ensuring the tip is on the dish’s bottom surface and in the microscope’s focus plane. Additionally, the paper introduces an on-the-spot method for breaking a micropipette tip and a preprocessing technique for somatic cells. The proposed micropipette tip-breaking method, using a low-cost acrylic ring, overcomes previous drawbacks and proves quick and user-friendly. The preprocessing technique converts fully adherent somatic cells into semi-adherent cells, increasing cell thickness for easier puncturing. Combining these techniques, the study validated the approaches through over 900 injections on human dermal fibroblast (HDF) cells, achieving a success rate of 53.3% and a survival rate of 95.8%.

13 August 2026 in Bio-Design and Manufacturing
Verified
Journal Article
Closed access
PDF file
QGQinghao Guo
Qinghao Guo
LZLiushuai Zheng
Liushuai Zheng
DXDongqin Xu
Dongqin Xu
YLYixin Liu
Yixin Liu
DSDingtong Shen
Dingtong Shen
Hao YangHao Yang
Hao Yang
Magnetic microrobots hold immense potential for various biomedical applications, including targeted drug delivery. However, their operational efficacy in c