Carlo Fiorini

Prof. Carlo Fiorini

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2017 in British Journal of Radiology
Verified
Journal Article
Open access
BHBrian F Hutton
Brian F Hutton
MOMichele Occhipinti
Michele Occhipinti
Andre KuehneAndre Kuehne
Andre Kuehne
DMDomokos Mathe
Domokos Mathe
NKNoémi Kovács
Noémi Kovács
OCOn behalf of the INSERT consortium
On behalf of the INSERT consortium
There is increasing clinical use of combined positron emission tomography and MRI, but to date there has been no clinical system developed capable of simultaneous single-photon emission computed tomography (SPECT) and MRI. There has been development of preclinical systems, but there are several challenges faced by researchers who are developing a clinical prototype including the need for the system to be compact and stationary with MRI-compatible components. The limited work in this area is described with specific reference to the Integrated SPECT/MRI for Enhanced stratification in Radio-chemo Therapy (INSERT) project, which is at an advanced stage of developing a clinical prototype. Issues of SPECT/MRI compatibility are outlined and the clinical appeal of such a system is discussed, especially in the management of brain tumour treatment.

24 August 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
LBLuca Buonanno
Luca Buonanno
Davide Di VitaDavide Di Vita
Davide Di Vita
Marco CarminatiMarco Carminati
Marco Carminati
CFCarlo Fiorini
Carlo Fiorini
Gain amplitude modulation multichannel ASIC (GAMMA) is a 16-channel application specified integrated circuit (ASIC), designed in 0.35- $\mu \text{m}$ technology to read the charge provided by silicon photomultipliers (SiPMs) on a wide amplitude range. This chip was designed to satisfy the demanding requirements of the INFN the GAMMA project, where a 3” $\times3$ ” large lanthanum bromide crystal is to be read by SiPMs, aiming at state-of-the-art energy resolution. Because the energy range of the application is 100 keV–20 MeV, signals in a wide dynamic range (DR) have to be processed by the ASIC. This wide DR requirement raised the necessity of an adaptive gain change solution in order to guarantee a high signal-to-noise ratio together with a large full-scale range. While the ASIC input stage features a programmable static gain, the analog filtering channel exploits a self-triggered gated integrator stage with an automatically adjusted gain for each detected input current pulse; one of the following values is selected: 10, 2, or 0.83 [mV/pC]. The gated integrator gain is predictively adjusted before the circuit reaches saturation due to a time-gated threshold mechanism and provides negligible charge loss when the gain is switched (< 20 fC). A preintegration feature is also implemented in order to get rid of nonlinearity due to delays in the integration phase that could take place in a multi-ASIC system. The ASIC uses 5- and 3.3-V bias voltages, the overall power consumption being 280 mW. The ASIC was tested with a $12\times12$ SiPMs matrix coupled with a 3 inch LaBr 3 , providing good spectroscopic performances (2.6% at the 137 Cs photopeak emission energy of 662 keV), and was also tested irradiating the SiPMs with fast, bright NUV light pulses, in order to explore the ASIC wide range coverage while simulating the scintillation light emission of a lanthanum bromide crystal.

21 January 2002 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
CFCarlo Fiorini
Carlo Fiorini
AGAlessandra Gianoncelli
Alessandra Gianoncelli
ALA. Longoni
A. Longoni
FZF. Zaraga
F. Zaraga

29 April 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
MPMatteo Porro
Matteo Porro
LALadislav Andricek
Ladislav Andricek
SAStefan Aschauer
Stefan Aschauer
ACAndrea Castoldi
Andrea Castoldi
MDMattia Donato
Mattia Donato
CWCornelia B. Wunderer
Cornelia B. Wunderer
The first DSSC 1-Mpixel camera became available at the European XFEL (EuXFEL) in the Hamburg area in February 2019. It was successfully tested, installed, and commissioned at the Spectroscopy and Coherent Scattering Instrument. DSSC is a high-speed, large-area, 2-D imaging detector system optimized for photon science applications in the energy range between 0.25 and 6 keV. The camera is based on direct conversion Si sensors and is composed of 1024 ×1024 pixels of hexagonal shape with a side length of 136 μm. The 256 application-specific integrated circuits (ASICs) provide full parallel readout, comprising analog filtering, digitization, and in-pixel data storage. In order to cope with the demanding X-ray pulse time structure of the EuXFEL, the DSSC provides a peak frame rate of 4.5 MHz. The first Mpixel camera is equipped with miniaturized silicon drift detector (MiniSDD) pixel arrays. The intrinsic response of the pixels and the linear readout limit the dynamic range but allow one to achieve noise values of about 60 electrons r.m.s. at the highest frame rate. The challenge of providing high-dynamic range (~10 4 photons/pixel/pulse) and single-photon detection simultaneously requires a nonlinear system front end, which will be obtained with the DEPFET active pixel technology foreseen for the advanced version of the camera. This technology will provide lower noise and a nonlinear response at the sensor level. This article describes the architecture of the whole detector system together with the main experimental results achieved up to now.

8 October 2020 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Verified
Journal Article
Closed access
LBLuca Buonanno
Luca Buonanno
Davide Di VitaDavide Di Vita
Davide Di Vita
Marco CarminatiMarco Carminati
Marco Carminati
CFCarlo Fiorini
Carlo Fiorini
The enhancement of a compact gamma-ray detection module for spectroscopy and imaging with machine learning for directional sensitivity is presented. In particular this development is targeted towards drone-based localization of radioactive sources in the environment. The unit is composed of a cylindrical monolithic scintillator crystal (3” × 3” LaBr3(Ce3++Sr2+)), read by an array of 144 solid-state SiPM detectors whose signals are conditioned by an integrated front-end. In addition to state-ofthe- art energy resolution (2.6% at 662 keV) and sub-centimeter spatial resolution in the reconstruction of the photon interaction point projected on the base, this portable unit enables the 2D angular localization of gamma sources on a plane parallel to the detectors array as a function of the reconstructed interaction point distribution, thanks to a decision tree. The classifier is compared with other techniques (k-NN, PCA) and optimized with 1000 splits. It runs in a 32-bit ARM micro-controller for real-time operation with a processing time of 2.75 μs per event, compatible with high gamma-ray counting rate (100 kcps) operation. Despite the absence of a collimator, classification is correct within ±30° for a single photon. Angular resolution of 0.5° and accuracy better than 2° are experimentally demonstrated (along with 0.8W power consumption and 3 kg weight), showing potential for identification of sources in the field.

13 July 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
PTPaolo Trigilio
Paolo Trigilio
PBPaolo Busca
Paolo Busca
RQRiccardo Quaglia
Riccardo Quaglia
MOMichele Occhipinti
Michele Occhipinti
CFCarlo Fiorini
Carlo Fiorini
In this paper, we present ANGUS, an application specific integrated circuit (ASIC) for silicon photomultiplier (SiPM) readout designed for low-energy gamma imaging (140 keV), specifically targeting clinical single photon emission computed tomography (SPECT) applications based on Angertype detectors. The chip is composed of 36 channels, each featuring a current conveyor input followed by an RC filter with a time constant programmable from 200 ns up to 10 μs, a baseline holder and a peak stretcher stage. Multichannel readout is performed with a polling strategy thanks to two analog multiplexers. The chip has been designed to cope with input capacitance values of several nanofarad, like the ones featured by the large-sized SiPM pixels (8 mm × 8 mm) of the application. Despite being conceived for operation with slow scintillator crystals like cesium-iodide (CsI), this ASIC can successfully manage the readout of faster crystals like lutetium-yttrium oxyorthosilicate. Measurements of the ASIC carried out on a fully equipped SPECT detection module have shown an energy resolution of 13.7% at the 140-keV line of 99m Tc, for a 5 cm × 5 cm gamma camera consisting of a continuous CsI crystal and a SiPM detection plane cooled at 0 °C.