Gilberto Valentim Silva

Gilberto Valentim Silva

Auto-generated profile, based on publicly available information

Gilberto Valentim Silva

Department of Electrotechnical Federal Institute of Santa Catarina Brazil

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GSGilberto Valentim Silva
Gilberto Valentim Silva
JAJéssika Melo de Andrade
Jéssika Melo de Andrade
Roberto Francisco CoelhoRoberto Francisco Coelho
Roberto Francisco Coelho
Telles Brunelli LazzarinTelles Brunelli Lazzarin
Telles Brunelli Lazzarin
This paper addresses a single-stage bi-directional step-up inverter designed from the integration of a differential boost inverter and switched-capacitor cells. The conventional boost inverter, even being a step-up topology, presents a gain limitation due to losses and therefore does not fully attend the step-up specifications. The insertion of switched-capacitor multiplier cells into it allows increasing its static gain without increasing the voltage stresses on its components. However, the resulting topology is nonlinear and contains a high amount of energy storage elements, which implies high order models. In this paper, static and dynamic analysis of the switched-capacitor differential boost inverter is performed under different types of modulation. A generalized and reduced order equivalent circuit and a small-signal average model are proposed, as well as a static gain linearization technique that reduces the harmonic distortion of the output voltage, regulated in closed loop by a resonant controller. The paper also presents the main waveforms, equation, and a comparison between the differential boost inverter and its version with switched-capacitor multiplier cells. To verify the study a 250 W prototype of rated power, input voltage of 60 V, switching frequency of 50 kHz and output voltage of 220 V is experimentally evaluated.

1 November 2015
Verified
Conference Paper
Closed access
GSGilberto V. Silva
Gilberto V. Silva
Roberto Francisco CoelhoRoberto Francisco Coelho
Roberto Francisco Coelho
TLTelles B. Lazzarin
Telles B. Lazzarin
The integration of Switched Capacitors (SC) and conventional converters provides advantages such as high gain, reduced stress and voltage regulation. However, it increases the system order and the complexity analysis. Therefore, this paper proposes the development of a methodology for modeling a hybrid switched-capacitor boost converter based on the state space modeling theory, which enables to study in detail these new topologies. Steady-state and dynamic models for operation in continuous conduction mode along with a brief converter analysis are still presented and verified by numerical simulation. As result of the state space modeling, the components stresses are obtained and, in addition, dynamic models are defined. Furthermore, from the proposed methodology a reduced order model is still derived, resulting in simplified transfer functions as well as the controllers design.

17 November 2016
Verified
Conference Paper
Closed access
GSGilberto Valentim Silva
Gilberto Valentim Silva
Roberto Francisco CoelhoRoberto Francisco Coelho
Roberto Francisco Coelho
TLTelles Brunelli Lazzarin
Telles Brunelli Lazzarin
The differential boost inverter (DBI) generates an alternating differential voltage from two dc-dc converters. The instantaneous output voltage can be higher or lower than the dc input voltage, however DBIs exhibit nonlinear control-to-output behavior in large-signal sense. Furthermore, switched capacitor cells may operate as a gain multiplier in classical converters. The integration of switched capacitors (SCs) and differential boost inverters may offer an attractive solution to provide high static gain. Thus, the novel inverter is intended to be used in applications whenever an ac voltage larger than the dc link voltage is needed, as UPS or even renewable energy supplies. The inverter based on boost converter and on switched capacitors is proposed in this paper, which is designated as switched capacitor differential boost inverter (SCDBI). The proposed inverter allows gains higher than the unity and increases the approximated linear region of boost-based inverter. In the proposed topology, the voltage stresses across the switches are reduced if compared with a traditional DBI. Topology, operational principle, analysis, modulation and simulation results are included in this paper.

9 March 2017
Verified
Conference Paper
Closed access
GSGilberto Valentim Silva
Gilberto Valentim Silva
Roberto Francisco CoelhoRoberto Francisco Coelho
Roberto Francisco Coelho
TLTelles Brunelli Lazzarin
Telles Brunelli Lazzarin
A novel structure based on differential boost inverter (DBI) and ladder structure of switched-capacitor (SC) is studied in this paper, which is designated as switched-capacitor differential boost inverter (SCDBI). The proposed inverter allows gains higher than unity and it extends the conversion rate of boost-type inverters. Hence, the insertion of the switched-capacitor extends the converter gain and thus it enables the minimization of the characteristic gain limitation in relation to losses of the boost converter. Furthermore, the series connection of more SC cells can improve the converter gain; thus a generalized structure is proposed in this study, which employs “k” SC cells. The proposed inverter is intended to be used in applications whenever an ac voltage larger than the dc link voltage is needed, as UPS, photovoltaic (PV) systems or even off-grid renewable energy supplies. Topology, principle of operation, ideal static gain, static gain considering the losses, generalized structure and simulation results are included in this paper.

1 January 2019 in Cadernos de Saude Publica
Verified
Journal Article
Open access
PDF file
ARAdriana da Silva dos Reis
Adriana da Silva dos Reis
ESEliana Amorim de Souza
Eliana Amorim de Souza
AFAnderson Fuentes Ferreira
Anderson Fuentes Ferreira
GSGilberto Valentim da Silva
Gilberto Valentim da Silva
SUYANNE MACEDOSUYANNE MACEDO
SUYANNE MACEDO
Alberto Novaes Ramos Jr.Alberto Novaes Ramos Jr.
Alberto Novaes Ramos Jr.
Resumo: Objetivou-se analisar a magnitude e o perfil sociodemográfico de casos de hanseníase vinculados a Redes de Convívio Domiciliar (RCD) com sobreposição da doença em dois municípios brasileiros, um da Região Norte e outro da Nordeste, de 2001 a 2014. Estudo transversal, descritivo e analítico, com base em dados primários e secundários de casos novos de hanseníase em indivíduos residentes em Picos, no Estado do Piauí, e em Rolim de Moura, no Estado de Rondônia. “Sobreposição” foi definida como casos novos com ocorrência de pelo menos mais um caso de hanseníase em sua RCD. Cada RCD foi composta por caso referência (primeiro caso notificado), casos coprevalentes (contatos que se tornaram casos novos) e contatos domiciliares de caso referência. Um total de 437 casos novos abordados pelos projetos INTEGRAHANS Norte-Nordeste e Piauí foram avaliados, 287 (65,7%) em Picos e 150 (34,3%) em Rolim de Moura. Do total de casos avaliados, 129 (44,9%) em Picos e 98 (65,3%) em Rolim de Moura relataram a ocorrência de sobreposição. Verificou-se maior frequência de pessoas do sexo feminino em Rolim de Moura (n = 95, 63,3%) e do masculino em Picos (n = 147, 51,2%); na faixa etária entre 41-60 anos de idade (Rolim de Moura n = 70, 46,7%; Picos n = 115, 40,1%); com ensino fundamental (Rolim de Moura n = 80, 54%; Picos n = 125, 44,5%) e que morava no mesmo domicílio com até 3 pessoas em Rolim de Moura (n = 105, 70%) e com mais de 4 pessoas em Picos (n = 287, 100%). A sobreposição de casos de hanseníase em RCD apresentou magnitude considerável nos contextos analisados, demonstrando aspectos de vulnerabilidade ampliada. Essa perspectiva deve ser considerada e integrada às ações de vigilância e controle da hanseníase.

31 December 2018 in Eletrônica de Potência
Verified
Journal Article
Open access
JAJéssika M. de Andrade
Jéssika M. de Andrade
GSGilberto V. Silva
Gilberto V. Silva
RCRoberto F. Coelho
Roberto F. Coelho
TLTelles B. Lazzarin
Telles B. Lazzarin
Neste artigo propõe-se o emprego do inversor boost diferencial a capacitor chaveado (SCDBI) em aplicações que requerem conexão com a rede elétrica. O SCDBI é um inversor elevador, cujo ganho pode ser aumentado a partir da adição de células a capacitor chaveado, e possui saída em tensão, o que permite injetar correntes na rede com baixa ondulação usando apenas um filtro L. Esses atributos favorecem o emprego da topologia em sistemas de estágio único, onde a tensão de entrada é menor que o valor de pico da tensão de saída. Alguns dos desafios atrelados ao uso do SCDBI estão relacionados à característica de ganho não linear e aos modelos dinâmicos de ordem elevada. Neste artigo, é proposta uma modelagem simplificada e uma técnica de linearização estática, que possibilitam a utilização de um controlador proporcional-integral e uma malha de feedforward para controlar a corrente injetada na rede elétrica. O trabalho também aborda a análise estática do conversor com modulação unipolar e apresenta os procedimentos de dimensionamento. A validação do estudo é feita através dos resultados obtidos a partir de um protótipo de 250 W, conectado à rede de 220 V eficaz, com tensão de entrada de 60 V, frequência de comutação de 50 kHz, rendimento de 90% e corrente de saída com THD menor que 5%.