Frank C. Sup

Frank C. Sup

Auto-generated profile, based on publicly available information

Frank C. Sup

Mechanical and Industrial Engineering, Riccio College of Engineering, University of Massachusetts Amherst, Engineering Laboratory, 160 Governors Drive, Amherst, MA, United States, 1 413-545-2946

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2008 in The International Journal of Robotics Research
Verified
Journal Article
Closed access
PDF file
FSFrank Sup
Frank Sup
ABAmit Bohara
Amit Bohara
MGMichael Goldfarb
Michael Goldfarb
The paper describes the design and control of a transfemoral prosthesis with powered knee and ankle joints. The initial prototype is a pneumatically actuated powered-tethered device, which is intended to serve as a laboratory test bed for a subsequent self-powered version. The prosthesis design is described, including its kinematic optimization and the design of a three-axis socket load cell that measures the forces and moments of interaction between the socket and prosthesis. A gait controller is proposed based on the use of passive impedance functions that coordinates the motion of the prosthesis with the user during level walking. The control approach is implemented on the prosthesis prototype and experimental results are shown that demonstrate the promise of the active prosthesis and control approach in restoring fully powered level walking to the user.

20 October 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HVHuseyin Atakan Varol
Huseyin Atakan Varol
FSFrank Sup
Frank Sup
MGMichael Goldfarb
Michael Goldfarb
This paper describes a control architecture and intent recognition approach for the real-time supervisory control of a powered lower limb prosthesis. The approach infers user intent to stand, sit, or walk, by recognizing patterns in prosthesis sensor data in real time, without the need for instrumentation of the sound-side leg. Specifically, the intent recognizer utilizes time-based features extracted from frames of prosthesis signals, which are subsequently reduced to a lower dimensionality (for computational efficiency). These data are initially used to train intent models, which classify the patterns as standing, sitting, or walking. The trained models are subsequently used to infer the user's intent in real time. In addition to describing the generalized control approach, this paper describes the implementation of this approach on a single unilateral transfemoral amputee subject and demonstrates via experiments the effectiveness of the approach. In the real-time supervisory control experiments, the intent recognizer identified all 90 activity-mode transitions, switching the underlying middle-level controllers without any perceivable delay by the user. The intent recognizer also identified six activity-mode transitions, which were not intended by the user. Due to the intentional overlapping functionality of the middle-level controllers, the incorrect classifications neither caused problems in functionality, nor were perceived by the user.

3 November 2009 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
FSFrank Sup
Frank Sup
HVHuseyin Atakan Varol
Huseyin Atakan Varol
JMJason Mitchell
Jason Mitchell
TWThomas J. Withrow
Thomas J. Withrow
MGMichael Goldfarb
Michael Goldfarb
This paper presents a self-contained powered knee and ankle prosthesis, intended to enhance the mobility of transfemoral amputees. A finite-state based impedance control approach, previously developed by the authors, is used for the control of the prosthesis during walking and standing. Experiments on an amputee subject for level treadmill and overground walking are described. Knee and ankle joint angle, torque, and power data taken during walking experiments at various speeds demonstrate the ability of the prosthesis to provide a functional gait that is representative of normal gait biomechanics. Measurements from the battery during level overground walking indicate that the self-contained device can provide more than 4500 strides, or 9 km, of walking at a speed of 5.1 km/h between battery charges.

14 October 2010 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
FSFrank Sup
Frank Sup
HVHuseyin Atakan Varol
Huseyin Atakan Varol
MGMichael Goldfarb
Michael Goldfarb
This paper extends a previously developed level- ground walking control methodology to enable an above knee amputee to walk up slopes using a powered knee and ankle prosthesis. Experimental results corresponding to walking on level ground and two different slope angles (5° and 10°) with the powered prosthesis using the control method are compared to walking under the same conditions with a passive prosthesis. The data indicate that the powered prosthesis with the upslope walking controller is able to reproduce several kinematic characteristics of healthy upslope walking that the passive prosthesis does not (such as knee flexion after heel strike and a powered ankle plantarflexion during push-off). Finally, results are shown that demonstrate the ability of the prosthesis to generate a slope estimate, which is in turn utilized to adapt the underlying control parameters to the corresponding slope.

5 July 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MPMark A. Price
Mark A. Price
PBPhilipp Beckerle
Philipp Beckerle
FSFrank C. Sup
Frank C. Sup
This review paper aims to develop a knowledge base and identify promising research pathways toward designing lower limb prostheses for optimal biomechanical and clinical outcomes. It is based on a literature search representing the state-of-the-art in lower limb prosthesis joint design and biomechanical analysis. Current design solutions are organized in terms of fulfilling four key functional roles body — support, propulsion, task flexibility, and loading relief. Biomechanical analyses of these designs reveal that the hypothesized outcomes are not consistently observed. We suggest that these outcomes may be improved by incorporating tools that can predict user performance metrics to optimize the device during the initial design process. We also note that the scope of the solution space of most current designs is limited by focusing on anthropomorphic design approaches that do not account for the person’s altered anatomy post-amputation. The effects of prosthetic joint behavior on whole-body gait biomechanics and user experience are likewise under-explored. Two research paths to support the goal of better predicting user outcomes are proposed: experimental parameterization of designs and model-based simulations. However, while work in these areas has introduced promising new possibilities, connecting both to improve real-world performance remains a challenge.

1 October 2008
Verified
Conference Paper
Closed access
FSFrank Sup
Frank Sup
HVHuseyin Atakan Varol
Huseyin Atakan Varol
JMJason Mitchell
Jason Mitchell
TWThomas Withrow
Thomas Withrow
MGMichael Goldfarb
Michael Goldfarb
This paper presents an overview of the design and control of an electrically powered knee and ankle prosthesis. The prosthesis design incorporates two motor-driven ball screw units to drive the knee and ankle joints. A spring in parallel with the ankle motor unit is employed to decrease the power consumption and increase the torque output for a given motor size. The devicepsilas sensor package includes a custom load cell to measure the sagittal socket interface moment above the knee joint, a custom sensorized foot to measure the ground reaction force at the heel and ball of the foot, and commercial potentiometers and load cells to measure joint positions and torques. A finite-state based impedance control approach, previously developed by the authors, is used and experimental results on level treadmill walking are presented that demonstrate the potential of the device to restore normal gait. The experimental power consumption of the device projects a walking distance of 5.0 km at a speed of 2.8 km/hr with a lithium polymer battery pack.