Gang Wu

Gang Wu

Auto-generated profile, based on publicly available information

Gang Wu

Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Centre for Rehabilitation Technical Aids, 100176, Beijing, China; Rehabilitation Hospital, National Research Center for Rehabilitation Technical Aids, 100176, Beijing, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Computers in Biology and Medicine
Verified
Journal Article
Open access
YYYan Yao
Yan Yao
ZMZhongjun Mo
Zhongjun Mo
GWGang Wu
Gang Wu
JGJunchao Guo
Junchao Guo
JLJian Li
Jian Li
Yubo FanYubo Fan
Yubo Fan
Personalized plates (P-Plates) could provide improved clinical outcomes in joint fusion by enabling perfect geometric matching between irregular bone and implants. However, there is no unified application framework for P-Plates for joint fusion. The objective of this study was to develop such a framework for P-Plates for tibiotalocalcaneal arthrodesis. A patient-specific bone model was constructed based on CT images, and the P-Plate was preliminarily designed to match the bones. Finite element method was used to optimize the stress distribution and to evaluate the biomechanical performance of the P-Plate by comparing it with a traditional plate (T-Plate). Then, the P-Plate was manufactured via electron beam melting and implanted into the foot of a patient. Increasing the size of the preliminary designed plate alleviated the stress concentration and reduced the risk of failure. The maximum stresses of the plate and screw (214.3 MPa, 99.05 MPa) and the maximum tensile force of the screw in the P-Plate (181.4 N) fixation system were lower than those in the T-Plate (217.4 MPa, 255.4 MPa, and 230.1 N, respectively). The P-Plate was well-matched to the bone, and no complications occurred. The P-Plate achieved American Orthopaedic Foot & Ankle Society and Short-Form-36 scores of 64 and 75, respectively, 36 months post operation, which suggests that it could improve clinical outcomes. The design and fabrication methods, as well as mechanical and postoperative performance evaluation methods, for the P-Plate were systematically developed and provide a reference for constructing a unified application framework for P-Plate use in tibiotalocalcaneal arthrodesis.


1 January 2024 in Chinese Optics
Verified
Journal Article
Closed access
PDF file
LQLiu Qing-Min
Liu Qing-Min
SHSun Hui-Jie
Sun Hui-Jie
SHShanglin Hou
Shanglin Hou
LJLei Jing-Li
Lei Jing-Li
WGWu Gang
Wu Gang
YZYan Zu-Yong
Yan Zu-Yong
理论分析了波长2 µm的掺铥光纤放大器中受激布里渊散射对激光输出性能的影响,研究了双包层掺铥光纤在793 nm的泵浦波长和1.9~2.1 µm的激光工作波段的光模分布、有效折射率、有效模场面积和归一化频率,数值计算了在1.9~2.1µm的激光工作波段双包层掺铥光纤中的布里渊频移和布里渊增益谱等SBS特性。利用增益光纤中的受激布里渊散射理论模型,研究了受激布里渊散射对掺铥光纤放大器激光输出性能的影响。在DTDF-10/130双包层掺铥光纤中,使用功率为100 W、波长为793 nm的连续光作为泵浦,可对波长为2 μm、功率为0.01 W的连续信号光进行放大。当泵浦光功率填充因子为0.01、0.02和0.03时,信号光的最大输出功率分别为25.27 W、31.08 W和34.06 W。对应的最佳双包层光纤长度为2.66 m、2.02 m和1.75 m,由受激布里渊散射产生的斯托克斯光功率分别为1.68 W、1.39 W和1.14 W。结果表明在掺铥光纤放大器中使用泵浦光功率填充因子大的双包层光纤可以降低光纤长度,以减小受激布里渊散射对信号激光输出功率的影响。本文的数值模型可以对光纤放大器的光纤长度进行优化,对提高实验效率、降低实验成本具有重要价值。