Fabiana Mantovani Gomes França

Fabiana Mantovani Gomes França

Auto-generated profile, based on publicly available information

Fabiana Mantovani Gomes França

Faculdade São Leopoldo Mandic

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2014 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
ENEduardo Aloisio Fleck Neumann
Eduardo Aloisio Fleck Neumann
CVCristina Cunha Villar
Cristina Cunha Villar
FFFabiana Mantovani Gomes França
Fabiana Mantovani Gomes França
Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK) and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface assembly. UCLA-type abutments were fixed to implants using titanium screws (Group 1), polyetheretherketone (PEEK) screws (Group 2), and 30% carbon fiber-reinforced PEEK screws (Group 3). The assemblies were placed on a stainless steel holding apparatus to allow for loading at 45o off-axis, in a universal testing machine. A 200 N load (static load) was applied at the central point of the abutment extremity, at a crosshead speed of 5 mm/minute, until failure. Data was analyzed by ANOVA and Tukey’s range test. The titanium screws had higher fracture resistance, compared with PEEK and 30% carbon fiber-reinforced PEEK screws (p < 0.05). In contrast, no statistically significant difference was observed between the fracture resistance of the PEEK and the 30% carbon fiber-reinforced PEEK screws (p> 0.05). Finally, visual analysis of the fractions revealed that 100% of them occurred at the neck of the abutment screw, suggesting that this is the weakest point of this unit. PEEK abutment screws have lower fracture resistance, in comparison with titanium abutment screws.

15 April 2010 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
AMAlexandre Pozo Maluf
Alexandre Pozo Maluf
RMRicardo Pozo Maluf
Ricardo Pozo Maluf
CBCecilia da Rocha Brito
Cecilia da Rocha Brito
FFFabiana Mantovani Gomes França
Fabiana Mantovani Gomes França
RBRui Barbosa de Brito
Rui Barbosa de Brito

1 March 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MFMelissa Proença Nogueira Fialho
Melissa Proença Nogueira Fialho
VHViviane Hass
Viviane Hass
RNRodrigo Proença Nogueira
Rodrigo Proença Nogueira
FFFabiana Mantovani Gomes França
Fabiana Mantovani Gomes França
CTCecilia Pedroso Turssi
Cecilia Pedroso Turssi
FAFlávia Lucisano Botelho Amaral
Flávia Lucisano Botelho Amaral

1 January 2019 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
FGFernanda Alvarez de Godoi
Fernanda Alvarez de Godoi
NCNatália Russo Carlos
Natália Russo Carlos
EBEnrico Coser Bridi
Enrico Coser Bridi
FAFlávia Lucisano Botelho Do Amaral
Flávia Lucisano Botelho Do Amaral
FFFabiana Mantovani Gomes França
Fabiana Mantovani Gomes França
RBRoberta Tarkany Basting
Roberta Tarkany Basting
The aim of this study was to evaluate soluble and insoluble fluoride concentrations in commercial varnishes, and their remineralization effect on artificial caries enamel lesions using surface and cross-sectional microhardness evaluations. Forty bovine enamel blocks were separated into four groups (n=10): control (no treatment), Enamelast (Ultradent Products), Duraphat (Colgate-Palmolive) and Clinpro White Varnish (3M ESPE). Surface enamel microhardness evaluations were obtained, artificial enamel caries lesions were developed by dynamic pH-cycling, and the varnishes were then applied every 6 days, after which the enamel blocks were submitted to dynamic remineralization by pH cycles. After removal of the varnishes, the enamel surfaces were reassessed for microhardness. The blocks were sectioned longitudinally, and cross-sectional microhardness measurements were performed at different surface depths (up to 300 μm depth). Polarized light microscopy images (PLMI) were made to analyze subsurface caries lesions. The fluoride concentration in whole (soluble and insoluble fluoride) and centrifuged (soluble fluoride) varnishes was determined using an extraction method with acetone. The data were analyzed to evaluate the surface microhardness, making adjustments for generalized linear models. There was a significant decrease in enamel surface microhardness after performing all the treatments (p<0.0001). Enamelast and Duraphat showed significantly higher enamel microhardness values than the control and the Clinpro groups (p = 0.0002). Microhardness loss percentage was significantly lower for Enamelast (p = 0.071; One-way ANOVA). PLMI showed that subsurface caries lesions were not remineralized with the varnish treatments. No significant differences in the in-depth microhardness levels (p = 0.7536; ANOVA) were observed among the treatments. Enamelast presented higher soluble and insoluble fluoride concentrations than the other varnishes (p < 0.0001; Kruskal-Wallis and Dunn tests). Enamelast and Duraphat varnishes promoted enamel surface remineralization, but no varnish remineralized the subsurface lesion body. Although insoluble and soluble fluoride concentration values did not correspond to those declared by the manufacturer, Enamelast presented higher fluoride concentration than the others.

1 January 2020 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
CBChristine Nagel Backes
Christine Nagel Backes
FFFabiana Mantovani Gomes França
Fabiana Mantovani Gomes França
CTCecilia Pedroso Turssi
Cecilia Pedroso Turssi
FAFlávia Lucisano Botelho Do Amaral
Flávia Lucisano Botelho Do Amaral
RBRoberta Tarkany Basting
Roberta Tarkany Basting
The aim of this in vitro study was to evaluate the color stability of a bulk-fill (Filtek One Bulk Fill, 3M ESPE) and a conventional (Filtek Z350 XT, 3M ESPE) composite resin light-cured at different distances, before and after being submitted to staining with a coffee solution. Sixty specimens of each composite resin were prepared and light-cured at distances of 0, 2 and 4 mm, using a LED light-curing unit (Valo, Ultradent). The specimens were separated (n = 10) for immersion in either distilled water or coffee solution (10 minutes a day for 8 days) to stimulate staining. Color evaluations were performed before and after immersion in the solutions, according to CIELab (△Eab), CIEDE2000 (△E00) and the Whiteness Index for Dentistry (△WID). Kruskal Wallis and Dunn tests, Mann-Whitney tests and Wilcoxon test were applied (α = 5 %). The a* value for conventional composite resin showed a significant increase after immersion in coffee and distilled water (p < 0.05). Both composite resins showed greater b* values when immersed in coffee than in distilled water, with no significant difference among the light-activation distances (p > 0.05). There was no significant difference for L* among the light-activation distances; both resins showed significant decrease in L* after immersion in coffee (p < 0.05). Color change (△Eab, △E00) and difference in whiteness (△WID) were higher for conventional resin when immersed in the coffee solution at all the light-activation distances. Conventional composite resin presented a higher staining value than bulk-fill composite resin, regardless of the light-activation distance.

1 January 2020 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
NMNaianne Ramos Monteiro
Naianne Ramos Monteiro
RBRosanna Tarkany Basting
Rosanna Tarkany Basting
FBFlávia Barbosa Silva Botelho
Flávia Barbosa Silva Botelho
FFFabiana Mantovani Gomes França
Fabiana Mantovani Gomes França
CTCecilia Pedroso Turssi
Cecilia Pedroso Turssi
RBRoberta Tarkany Basting
Roberta Tarkany Basting
This study evaluated physicochemical properties of bleaching agents incorporated with titanium dioxide (TiO2) nanotubes, and the effects on tooth color change at different periods. 40 premolars were treated according to the following groups (n=10): CP - 10% carbamide peroxide (1 hour daily/21 days); CPN - CP incorporated into TiO2; HP - 40% hydrogen peroxide (three 40-minute sessions/7 days apart); HPN - HP incorporated into TiO2. Color shade was evaluated at five different periods (baseline, after 7, 14 and 21 days of bleaching, and 7 days after end of treatment) according to Vita Classical, CIELab and CIEDE2000 scales. Mean particle size (P), polydispersity (PO) and zeta potential (ZP) were evaluated using dynamic light scattering. Data on the different variables were analyzed by mixed model tests for measures repeated in time (ZP e L*), generalized linear models for measures repeated in time (P, PO, Vita Classical and b*), and Friedman and Mann-Whitney tests (a* and color change/ΔE and ΔE00). CP and CPN presented higher P, higher PO and lower ZP than HP and HPN (p≤0.05). All groups showed a significant decrease in Vita Classical color scores after 7 days of bleaching (p0.05) in bleaching time. A significant reduction occurred in the a* and b* values for all the groups, and HPN presented lower a* and b* values (p<0.05) than CPN. ΔE was clinically noticeable after 7 days, in all groups, and all groups resulted in a perceptible color change according to ΔE00. TiO2 did not influence physicochemical properties of the bleaching agents. HPN presented more effective tooth bleaching than CPN.