John Ryan Martin

John Ryan Martin

Auto-generated profile, based on publicly available information

John Ryan Martin

Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2023 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
AMAleksander Mika
Aleksander Mika
JMJ. Ryan Martin
J. Ryan Martin
SEStephen M. Engstrom
Stephen M. Engstrom
GPGregory G. Polkowski
Gregory G. Polkowski
JWJacob M. Wilson
Jacob M. Wilson
Background: The contemporary patient has access to numerous resources on common orthopaedic procedures before ever presenting for a clinical evaluation. Recently, artificial intelligence (AI)-driven chatbots have become mainstream, allowing patients to engage with interfaces that supply convincing, human-like responses to prompts. ChatGPT (OpenAI), a recently developed AI-based chat technology, is one such application that has garnered rapid growth in popularity. Given the likelihood that patients may soon call on this technology for preoperative education, we sought to determine whether ChatGPT could appropriately answer frequently asked questions regarding total hip arthroplasty (THA). Methods: Ten frequently asked questions regarding total hip arthroplasty were posed to the chatbot during a conversation thread, with no follow-up questions or repetition. Each response was analyzed for accuracy with use of an evidence-based approach. Responses were rated as “excellent response not requiring clarification,” “satisfactory requiring minimal clarification,” “satisfactory requiring moderate clarification,” or “unsatisfactory requiring substantial clarification.” Results: Of the responses given by the chatbot, only 1 received an “unsatisfactory” rating; 2 did not require any correction, and the majority required either minimal (4 of 10) or moderate (3 of 10) clarification. Although several responses required nuanced clarification, the chatbot’s responses were generally unbiased and evidence-based, even for controversial topics. Conclusions: The chatbot effectively provided evidence-based responses to questions commonly asked by patients prior to THA. The chatbot presented information in a way that most patients would be able to understand. This resource may serve as a valuable clinical tool for patient education and understanding prior to orthopaedic consultation in the future.

20 December 2023 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
JMJ. Ryan Martin
J. Ryan Martin
RCRogelio A. Coronado
Rogelio A. Coronado
JWJacob M. Wilson
Jacob M. Wilson
GPGregory G. Polkowski
Gregory G. Polkowski
ASAndrew A. Shinar
Andrew A. Shinar
SBStephen P. Bruehl
Stephen P. Bruehl

1 January 2024 in JBJS Reviews
Verified
Journal Article
Closed access
PCPeter Chan
Peter Chan
AMAleksander Mika
Aleksander Mika
JMJ. Ryan Martin
J. Ryan Martin
JWJacob M. Wilson
Jacob M. Wilson
» Orthopaedic surgeons are increasingly likely to encounter patients with obesity and/or type 2 diabetes taking glucagon-like peptide-1 (GLP-1) agonists for weight loss. » GLP-1 agonists are an effective treatment for weight loss with semaglutide and tirzepatide being the most effective agents. Randomized controlled trials using these agents have reported weight loss up to 21 kg (46 lb). » The use of GLP-1 agonists preoperatively can improve glycemic control, which can potentially reduce the risk of postoperative complications. However, multiple cases of intraoperative aspiration/regurgitation have been reported, potentially related to the effect of GLP-1 agonists on gastric emptying. » While efficacious, GLP-1 agonists may not produce sufficient weight loss to achieve body mass index cutoffs for total joint arthroplasty depending on individual patient factors, including starting bodyweight. Multifactorial approaches to weight loss with focus on lifestyle modification in addition to GLP-1 agonists should be considered in such patients. » Although GLP-1 agonists are efficacious agents for weight loss, they may not be accessible or affordable for all patients. Each patient's unique circumstances should be considered when creating an ideal weight loss plan during optimization efforts.

31 December 2022 in The Knee
Verified
Journal Article
Closed access
ZCZach C. Cox
Zach C. Cox
SEStephen M. Engstrom
Stephen M. Engstrom
ASAndrew A. Shinar
Andrew A. Shinar
GPGregory G. Polkowski
Gregory G. Polkowski
JMJ. Bohannon Mason
J. Bohannon Mason
JMJ. Ryan Martin
J. Ryan Martin

29 May 2024 in The Journal of Arthroplasty
Verified
Journal Article
Open access
ACAnoop S. Chandrashekar
Anoop S. Chandrashekar
AHAlicia M. Hymel
Alicia M. Hymel
JPJacquelyn S. Pennings
Jacquelyn S. Pennings
JWJacob M. Wilson
Jacob M. Wilson
RGRajnish K. Gupta
Rajnish K. Gupta
JMJ. Ryan Martin
J. Ryan Martin
Spinal anesthesia (SA) is the preferred anesthesia modality for total joint arthroplasty (TJA). However, studies establishing SA as preferential may be subject to selection bias given that general anesthesia (GA) is often selectively utilized on more difficult, higher-risk operations. The optimal comparison group, therefore, is the patient converted to GA due to a failed attempt at SA. The purpose of this study was to determine risk factors and outcomes following failed SA with conversion to GA during primary total hip arthroplasty (THA) or total knee arthroplasty (TKA). A consecutive cohort of 4,483 patients who underwent primary TJA at our institution was identified (2,004 THA and 2,479 TKA). Of these patients, 3,307 underwent GA (73.8%), 1,056 underwent SA (23.3%), and 130 patients failed SA with conversion to GA (2.90%). Primary outcomes included rescue analgesia requirement in the postanesthesia care unit (PACU), time to ambulation, pain scores in the PACU, estimated blood loss, and 90-day complications. Risk factors for SA failure included older age and a higher comorbidity burden. Failure of SA was associated with increased estimated blood loss, rescue intravenous opioid use, and time to ambulation when compared to the successful SA group in both THA and TKA patients (P < .001). The anesthesia modality was not associated with significant differences in PACU pain scores. The 90-day complication rate was similar between the failed SA and GA groups. There was a higher incidence of postoperative pain prompting unplanned visits and thromboembolism when comparing failed SA to successful SA in both THA and TKA patients (P < .05). In our series, patients who had failed SA demonstrated inferior outcomes to patients receiving successful SA and similar outcomes to patients receiving GA who did not have an SA attempt. This emphasizes the importance of success in the initial attempt at SA for optimizing outcomes following TJA.

17 October 2024 in Arthroplasty Today
Verified
Journal Article
Open access
CFChristian Fölsch
Christian Fölsch
JSJulia Schirmer
Julia Schirmer
CGCosmin Glameanu
Cosmin Glameanu
BIBernd Ishaque
Bernd Ishaque
CUCarlos Alfonso Fonseca Ulloa
Carlos Alfonso Fonseca Ulloa
AJAlexander Jahnke
Alexander Jahnke
Application time and viscosity are factors that can significantly affect the properties of bone cement and implant fixation. The aim of this study was to investigate the influence of different application times of 2 different cements on mechanical parameters, cement interdigitation, and cement distribution. P.F.C. Sigma tibial trays were cemented with high-viscous Palacos R and medium- to low-viscous Simplex P in an open-cell model. The application was performed at different times within the manufacturer’s specifications. Cement interdigitation and micromotion were measured with computed tomography scan using a novel method. Significant differences of insertion forces were found at all times of cement application. Cement penetration decreased with increasing pressure and viscosity. No significant differences were shown for micromotion between Palacos R and Simplex P except for an increase for Simplex P from 3 to 7 minutes at the bone-cement interface. Simplex P appeared to trap air at the implant-cement interface at 3 minutes and increased at 7 minutes. Cement distribution and intrusion of Palacos R and Simplex P decreased with time. Simplex P trapped air at the implant-cement interface, decreasing the amount of contact at the implant-cement interface, which is worrisome for long-term implant fixation. Given the significant changes in cement properties after mixing, it is necessary for surgeons to understand the viscosity and timing of cement application to achieve optimal cement penetration and surface contact area to potentially decrease implant loosening. High-viscous Palacos R should be applicated immediately with doughing time and medium-viscous Simplex P for about 4 minutes considering a threshold of minimum pressure.