Dongseob Lee

Dongseob Lee

Auto-generated profile, based on publicly available information

Dongseob Lee

Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
DLDongseob Lee
Dongseob Lee
JLJungwon Lee
Jungwon Lee
KKKi-Tae Koo
Ki-Tae Koo
YSYang-Jo Seol
Yang-Jo Seol
YLYong-Moo Lee
Yong-Moo Lee
Lee D, et al. J Periodontal Implant Sci. 2022 Sep;52:e36. https://doi.org/10.5051/jpis.2202760138

5 June 2024 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
YKYoung-Chang Ko
Young-Chang Ko
DLDongseob Lee
Dongseob Lee
KKKi-Tae Koo
Ki-Tae Koo
YSYang-Jo Seol
Yang-Jo Seol
YLYong-Moo Lee
Yong-Moo Lee
JLJungwon Lee
Jungwon Lee
Purpose: This study evaluated the implant stability, volumetric changes, and patient-reported outcome measures (PROMs) of hydroxyapatite (HA) nano-coated sandblasted/acid-etched (SLA) implants compared to uncoated SLA implants. Methods: Forty patients were recruited and randomly allocated to HA nano-coated SLA group (test, n = 20) and uncoated SLA group (control, n = 20) using single-blinded/block randomization. Implants were immediately placed in maxillary posterior region using a digital surgical guide. Insertion torque and implant stability quotient (ISQ) were measured at implant surgery and 1, 2, 3, and 4 months postoperatively. Intraoral scans, PROMs and soft tissue inflammation data were collected, and multivariable linear regression analysis of ISQ was performed. Results: In total, 48 implants (test; n = 24, control; n = 24) in 37 patients (test; n = 19, control; n = 18) were analyzed. Despite no significant between-group difference at surgery, the test group showed higher ISQ values than the control group at 2 (76.53 ± 4.17 vs. 71.32 ± 4.79, p < 0.01), 3 (77.45 ± 4.41 vs. 73.85 ± 4.69, p < 0.05), and 4 months (79.08 ± 2.96 vs. 73.43 ± 3.52, p < 0.0001) postoperatively. There were no significant differences in linear and volumetric changes, PROMs, and soft tissue inflammation analysis between two groups. The ISQ at implant surgery was influenced by age and diabetes mellitus (DM) at the implant level and DM and predicted total bone-to-implant contact area at the patient level. Conclusion: HA nano-coated SLA implants promoted favorable immediate implants stability during early osseointegration phase compared to uncoated SLA implants, but displayed similar dimensional changes, PROMs, and soft tissue inflammation outcomes. Trial registration: Clinical Research Information Service (CRIS), KCT0006364. Registered 21 July 2021, https://cris.nih.go.kr/cris/search/detailSearch.do?seq=24221&search_page=L.

6 October 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DLDongseob Lee
Dongseob Lee
JLJungwon Lee
Jungwon Lee
YSYang-Jo Seol
Yang-Jo Seol
YLYong-Moo Lee
Yong-Moo Lee
KKKi-Tae Koo
Ki-Tae Koo
This study investigated early bone formation using collagenated biphasic calcium phosphate (CBCP) with or without polynucleotide (PDRN). Third (P3) or fourth (P4) premolars of six male beagle dogs were extracted and 5-mm-high dehiscence defects were created, followed by 3D-printed implant placement. The buccal bone defects were grafted with (i) CBCP and collagen membrane or (ii) CBCP soaked in polydeoxyribonucleotide (CBCP/PDRN) and collagen membrane. Samples of the experimental sites were harvested at 2- and 6-weeks post-surgery. The specimens were evaluated with radiologic and histomorphometric analysis. No significant differences were found between the CBCP and CBCP/PDRN groups in the micro-CT analysis at 2 or 6 weeks. No significant differences were observed in bone-to-implant contact (BIC) or bone area fraction occupancy (BAFO) in buccal augmented and lingual non-augmented areas. In the qualitative analysis, the new bone (NB) area and NB proportion in buccal augmented areas showed significantly higher values in the CBCP/PDRN group than in the CBCP group at 2 and 6 weeks. Peri-implant buccal dehiscence defects with immediate 3D-printed implant placement were corrected using a collagen membrane and CBCP or CBCP/PDRN. PDRN might have the potential to facilitate early bone formation with sufficient stability over time in dehiscence defects.

29 November 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HSHyemee Suh
Hyemee Suh
DLDongseob Lee
Dongseob Lee
JLJungwon Lee
Jungwon Lee
YSYang-Jo Seol
Yang-Jo Seol
YLYong-Moo Lee
Yong-Moo Lee
KKKi-Tae Koo
Ki-Tae Koo
In recent years, 3D-printing technology to fabricate dental implants has garnered widespread attention due to its patient-specific customizability and cost-effectiveness. This preclinical animal study analyzed the radiographic and histomorphometric outcomes of 3D-printed implants (3DIs) placed immediately after extraction and compared them to conventional implants (CIs). 3DIs and CIs of the same dimensions placed immediately were analyzed at 2, 6, and 12 weeks. The micro-computed tomography (micro-CT) analysis revealed statistically significant differences at 2 weeks in favor of 3DIs over the CIs in terms of bone volume/tissue volume (BV/TV), bone surface/bone volume (BS/BV), trabecular bone pattern factor (Tb.Pf), and structure model index (SMI). At 2 weeks, the mean bone-to-implant contact (BIC) of the 3DIs was greater than that of the CIs; the mean bone area fraction occupancy (BAFO) and the number of Haversian canals of the 3DIs showed no statistically significant differences compared to CIs at 2 weeks. At 6 and 12 weeks, there were no statistically significant differences between the 3DIs and CIs in any parameters. Within limitations, in the early stage of extraction socket healing, the 3DIs demonstrated a higher BIC than the CIs, presenting that 3DIs may be a potential option for immediate placement to enhance osseointegration.

13 August 2023 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
DLDongseob Lee
Dongseob Lee
YKYoung‐Chang Ko
Young‐Chang Ko
YSYang-Jo Seol
Yang-Jo Seol
KKKi-Tae Koo
Ki-Tae Koo
YLYong‐Moo Lee
Yong‐Moo Lee
JLJungwon Lee
Jungwon Lee

1 January 2024 in Biomaterials Research
Verified
Journal Article
Open access
DLDongseob Lee
Dongseob Lee
YKYoung-Chang Ko
Young-Chang Ko
KKKi-Tae Koo
Ki-Tae Koo
YSYang-Jo Seol
Yang-Jo Seol
YLYong-Moo Lee
Yong-Moo Lee
JLJungwon Lee
Jungwon Lee
Collagen membranes play a crucial role in guided bone regeneration (GBR) by preventing soft tissue infiltration and maintaining space for bone formation. This study investigated the impact of collagen membrane flexibility on GBR outcomes through in vitro and in vivo analyses. Flexible (0.3 mm in width) and stiff (0.5 mm in width) porcine collagen membranes were compared. In vitro tests assessed hydrophilicity, enzymatic degradation, conformability, space maintenance, and tensile strength. An in vivo study using a canine model evaluated bone regeneration in standardized mandibular defects filled with deproteinized porcine bone mineral and covered with no membrane, flexible membrane, or stiff membrane. Micro-computed tomography and histomorphometric analyses were performed at 8 and 16 weeks. The flexible membrane demonstrated superior hydrophilicity, faster enzymatic degradation, and greater conformability in vitro. In vivo, micro-computed tomography analysis revealed similar alveolar ridge widths across all groups. Histomorphometric analysis at 16 weeks showed significantly larger regenerated areas in the flexible membrane group compared to controls in coronal, middle, and apical regions. Both membrane groups exhibited higher regeneration ratios than controls, with significant differences in the coronal area. The flexible membrane group demonstrated significantly higher new bone formation in all regions compared to controls at 16 weeks. These findings suggest that flexible membrane substantially enhances GBR outcomes by increasing hydrophilicity and conformability. The study highlights the potential clinical benefits of incorporating flexible membranes in GBR procedures for improved bone regeneration outcomes.