Israt Jahan Nipa

Israt Jahan Nipa

Auto-generated profile, based on publicly available information

Israt Jahan Nipa

Medical College For Women and Hospital, VC52+87 V, Plot No 4 Road-8/9, Sector-1, Uttara, Dhaka 1230, Bangladesh

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2026 in Journal of Electrical Bioimpedance
Verified
Journal Article
Open access
PDF file
Md Mainuddin SagarMd Mainuddin Sagar
Md Mainuddin Sagar
INIsrat Jahan Nipa
Israt Jahan Nipa
Kihan ParkKihan Park
Kihan Park
Electrical Impedance Tomography (EIT) provides low-cost functional impedance imaging, whereas ultrasound offers high-resolution morphological visualization. In this study, a hybrid Ultrasound–EIT (EIT–US) fusion framework is developed for soft-tissue characterization in layered ex vivo biological phantoms using controlled chicken tissue models. A custom EIT acquisition system recorded 208 boundary voltage measurements per acquisition across three tissue layers and multiple frequency–voltage conditions, with experiments repeated across three anatomical tissue configurations. Five FEM-based reconstruction methods—Back Projection (BP), Gauss–Newton (GN), Tikhonov regularization (TIK), GREIT, and a linearized EIDORS-like approach—were implemented within a stand-alone MATLAB framework. Ultrasound images acquired using a GE VScan Air CL probe (musculoskeletal mode) were integrated with EIT reconstructions through a multimodal fusion pipeline incorporating impedance imaging, ultrasound texture–echogenicity mapping, and statistical correlation analysis. Quantitative evaluation demonstrated consistent layer differentiation with moderate structural–electrical agreement ( r ≈ 0.37–0.45). ESI increased by more than 60% at the evaluated layer interfaces during the fusion approach compared to EIT-only reconstructions, along with an increase in boundary detection performance (AUC improvement of approximately 0.13–0.15). Structural similarity (SSIM) of the fused images relative to ultrasound boundaries ranged from 0.71 to 0.78, indicating preserved spatial coherence. Frequency and voltage variations influenced reconstruction stability and contrast recovery. Overall, multimodal fusion improved the structural interpretability of EIT by anchoring conductivity distributions to ultrasound-derived morphological boundaries. These results indicate that incorporating ultrasound-derived structural priors improves the interpretability of EIT reconstructions by providing spatial context to conductivity distributions. This framework provides a practical experimental approach for integrating complementary electrical and acoustic sensing modalities, with potential relevance to future low-cost and portable soft-tissue imaging systems.

13 January 2026 in Inverse Problems
Verified
Journal Article
Closed access
Md Mainuddin SagarMd Mainuddin Sagar
Md Mainuddin Sagar
INIsrat Jahan Nipa
Israt Jahan Nipa
MPMishal Pokharel
Mishal Pokharel
TMTrani Menaka Bandara Konara Konara Mudiyanselage
Trani Menaka Bandara Konara Konara Mudiyanselage
Kihan ParkKihan Park
Kihan Park
Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that reconstructs interior conductivity from surface voltage measurements. This study benchmarks five finite element–based reconstruction algorithms-Back Projection (BP), Gauss–Newton (GN), Tikhonov Regularization (TR), GREIT, and EIDORS FEM-under controlled hardware conditions. A 16-electrode saline phantom integrated with multiplexers, an amplifier, a function generator, an Arduino Mega, and a DAQ was used, with chicken breast tissue inserted at four unique positions to mimic tumors. Across four excitation signals (10 kHz/1 Vpp, 50 kHz/1 Vpp, 10 kHz/5 Vpp, 50 kHz/5 Vpp), the methods yielded 80 reconstructed images. Performance was evaluated using quantitative metrics including contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), root mean square error (RMSE), frequency-domain Fast Fourier Transform (FFT), spectrograms, wavelet transform, and spectral temporal energy ratio (STER) to evaluate each method’s performance and robustness. According to our investigation, there are notable variations in image fidelity based on the reconstruction technique and the signal circumstances. Back Projection exhibited artifacts and lower spatial resolution, whereas GREIT and Tikhonov showed the strongest resilience and noise suppression, with EIDORS offering advantages following them. By integrating real hardware signals with phantom experiments, this work offers a practical benchmarking framework and guidance to enhance medical and industrial EIT systems.