Nathan Xie

Nathan Xie

Auto-generated profile, based on publicly available information

Nathan Xie

NeuroSpine Surgery Research Group (NSURG), Randwick, NSW, Australia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2022 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
NXNathan Xie
Nathan Xie
PWPeter J. Wilson
Peter J. Wilson
RRRajesh Reddy
Rajesh Reddy

1 August 2024 in Journal of Surgical Case Reports
Verified
Journal Article
Open access
PDF file
AMAlison Ma
Alison Ma
NXNathan Xie
Nathan Xie
JRJoseph Reidy
Joseph Reidy
RMRalph Mobbs
Ralph Mobbs
Endoscopic spine surgery has evolved exponentially. However, the two-dimensional (2D) view results in lack of stereoscopic vision and depth perception, contributing to the steep learning curve. This case report recounts a world first trial of a three-dimensional (3D) endoscopic system that converts 2D to 3D images and explores its potential role in the surgical management of degenerative lumbar spine diseases. The 3D endoscopic system was used for two patient cases and both 2D and 3D images were displayed side by side and compared. Advantages of the 3D endoscopic system include increased perception of depth, rapid identification of bleeding points, and greater visualization of anatomical details. Field of view and exposure were identical in 2D and 3D views. Limitations include costs and need for additional equipment. Overall, 3D endoscopy improved depth perception, instrument manoeuvrability, and recognition of anatomical details. This case report can guide further research and training in endoscopic spine surgery.

21 January 2022 in Journal of Surgical Case Reports
Verified
Journal Article
Open access
PDF file
NXNathan Xie
Nathan Xie
SKSihyong J Kim
Sihyong J Kim
RMRalph Mobbs
Ralph Mobbs
RRRajesh Reddy
Rajesh Reddy
Radiolucent pedicle screw fixation has become popularized in the field of oncological spine surgery owing to its ability to provide superior post-operative planning for adjuvant radiotherapy and radiological monitoring of tumour progression. We present the case of a 45-year-old female with degenerative spine pathology who underwent L4/5 and L5/S1 posterior lumbar interbody fusion with carbon fibre reinforced-polyetheretherketone pedicle screw fixation. The authors highlight the potential advantages of radiolucent pedicle fixation, which may translate into the degenerative spine surgery domain.

1 June 2026 in Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
AMAlison Ma
Alison Ma
RMRalph Mobbs
Ralph Mobbs
NXNathan Xie
Nathan Xie
JRJoseph Reidy
Joseph Reidy
Background: Endoscopic spine surgery reduces tissue damage, blood loss and postoperative pain. However, the two-dimensional (2D) view prevents depth perception and spatial orientation, contributing to a steep learning curve. Three-dimensional (3D) endoscopes improve depth perception but introduce increased scope diameter, workflow disruption and reduced image quality. A novel algorithm-based 3D visualisation system enables real-time conversion of standard 2D endoscopic images into 3D without requiring a dedicated 3D endoscope. Its impact on surgical workflow and intraoperative performance in spine surgery remains unknown. Case Description: 14 patients with degenerative spinal pathology underwent endoscopic surgery using a real-time 2D-to-3D conversion system (13 uniportal, 1 biportal). Outcomes were assessed across predefined domains: (I) visualisation; (II) instrument handling; (III) haemostasis; (IV) educational impact; (V) workflow; and (VI) ergonomics. Improved visualisation (depth perception and spatial orientation) were observed in all cases. Improved instrument handling (navigation and drill control) was observed in all decompression cases (10/10). Enhanced haemostasis recognition was reported in 6/10 applicable cases. Educational benefit was observed in 6/14 cases. Workflow disruption occurred in 4/14 cases and ergonomic symptoms (mild dizziness or double vision) were reported in 6/14 cases. Field of view was equivalent between 2D and 3D imaging. No dural injuries, neurological deficits or reoperations occurred. All patients demonstrated recovery consistent with expected postoperative trajectories. Conclusions: This case series demonstrates the potential for 3D endoscopy to be used as an adjunct in endoscopic spine surgery with improvements in depth perception, instrument handling and visualisation of spatial relationships without altering endoscope diameter or access corridors. While an initial familiarisation phase is required, the system demonstrates potential workflow and educational value. Further prospective studies with quantitative metrics and long-term outcomes are warranted.