Alison Ma

Ms. Alison Ma

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2025 in International Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
AMAlison Ma
Alison Ma
RMRalph Mobbs
Ralph Mobbs
MMMonish Maharaj
Monish Maharaj
Background There has been a gradual shift from open spine surgery to minimally invasive techniques such as endoscopic spine surgery to reduce approach-related trauma, collateral damage, and complications. While recovery following surgery has been measured using subjective measures including patient-reported outcome measures, the introduction of smart wearable devices now provides both an objective and continuous method of patient assessment. This prospective study compares patient recovery after uniportal endoscopic and open lumbar spine surgery by analyzing mobility and gait metrics captured by a wearable sensor. Methods Participants included 24 patients who underwent a single-level uniportal endoscopic lumbar decompression or open posterior lumbar fusion. During the first 48 hours after surgery, patients wore a sensor that continuously monitored position, step count, and gait metrics. Results In the immediate postoperative period, endoscopic spine surgery patients experienced a quicker return to mobility, with less time lying down, higher step count, faster gait velocity, lower double support percentage, and reduced variability, compared with open spine surgery patients. Conclusion There are key differences in patient mobility and gait following uniportal endoscopic and open spine surgery. Endoscopic spine surgery patients had faster recovery, which can guide resource allocation toward the development of training programs and support the advancement of spine endoscopy to address a broader range of pathologies. This pilot study highlights the potential for wearable devices to be used in further studies to form spine surgery recovery trajectories, allowing targeted rehabilitation and prompt intervention for deviations in patient recovery. Clinical Relevance This study demonstrates the benefits of endoscopic spine surgery for improved postoperative recovery in terms of mobility and gait metrics. Additionally, it highlights the potential for wearable sensor technology to provide an objective and continuous method for assessing postoperative outcomes and for the development of individualized rehabilitation protocols. These findings support the broader adoption of endoscopic techniques and emphasize the value of incorporating wearable devices into postoperative monitoring to optimize patient care. Level of Evidence 3.

1 August 2024 in Journal of Surgical Case Reports
Verified
Journal Article
Open access
PDF file
AMAlison Ma
Alison Ma
NXNathan Xie
Nathan Xie
JRJoseph Reidy
Joseph Reidy
RMRalph Mobbs
Ralph Mobbs
Endoscopic spine surgery has evolved exponentially. However, the two-dimensional (2D) view results in lack of stereoscopic vision and depth perception, contributing to the steep learning curve. This case report recounts a world first trial of a three-dimensional (3D) endoscopic system that converts 2D to 3D images and explores its potential role in the surgical management of degenerative lumbar spine diseases. The 3D endoscopic system was used for two patient cases and both 2D and 3D images were displayed side by side and compared. Advantages of the 3D endoscopic system include increased perception of depth, rapid identification of bleeding points, and greater visualization of anatomical details. Field of view and exposure were identical in 2D and 3D views. Limitations include costs and need for additional equipment. Overall, 3D endoscopy improved depth perception, instrument manoeuvrability, and recognition of anatomical details. This case report can guide further research and training in endoscopic spine surgery.

1 December 2025 in Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
AMAlison Ma
Alison Ma
JRJoseph Reidy
Joseph Reidy
RMRalph Mobbs
Ralph Mobbs
Background: Endoscopic spine surgery has emerged as a significant advancement in minimally invasive spinal procedures, with advantages including reduced tissue trauma, faster recovery, and improved patient outcomes. A critical component of these surgeries is effective haemostasis, essential for maintaining visual clarity, ensuring surgical efficiency, and minimising perioperative complications. A scoping review was conducted to examine current clinical practices and research on haemostasis in endoscopic spine surgery, with the aim of synthesising existing knowledge into a practical framework to guide surgeons in managing intraoperative bleeding in endoscopic spine surgery. Methods: A comprehensive literature search was conducted across PubMed, Embase and Cochrane Library, guided by the Population-Concept-Context (PCC) framework. Studies were included if they reported on techniques to achieve haemostasis in endoscopic spine procedures. Data were extracted on study design, surgical technique, haemostatic tools or agents used, and bleeding-related outcomes. Results: The review identified various haemostatic methods including bipolar and radiofrequency cautery, tranexamic acid, gelatin-thrombin matrix sealants, bone wax, irrigation pressure modulation, and absorbable hemostatic agents. The review highlights that no single haemostatic method can be applied to all cases of endoscopic spine surgery. Instead, a multimodal approach is necessary to effectively achieve haemostasis. Based on this synthesis, we propose the FIBRE protocol, encompassing fluid management, initial exposure, bone bleeding control, red-out scenarios, and extra considerations, as a practical framework for managing haemostasis. Conclusions: The proposed FIBRE protocol is a framework for controlling bleeding, improving visualisation, and enhancing surgical outcomes. By integrating these practices, surgeons can refine their techniques and contribute to enhanced patient outcomes in minimally invasive spine surgery.

25 August 2025 in Journal of Clinical Neuroscience
Verified
Journal Article
Open access
RMRalph J. Mobbs
Ralph J. Mobbs
JLJiun-Lih Lin
Jiun-Lih Lin
CHChristopher Huang
Christopher Huang
RPRichard Parkinson
Richard Parkinson
AMAlison Ma
Alison Ma
L5-S1 pathologies including foraminal disc herniation, foraminal stenosis and spondylolisthesis are well-recognized causes of radicular pain, functional limitation, and diminished quality of life, with many patients requiring surgical intervention due to refractory symptoms or progressive neurological compromise [1,2]. Traditionally, surgical decompression at L5-S1 has involved interbody fusion procedures, aimed at restoring foraminal height and stabilizing the segment to relieve nerve root impingement [3]. However, these procedures can result in prolonged recovery times, increased surgical morbidity, and the long-term risk of adjacent segment degeneration [4,5]. In recent years, endoscopic techniques have emerged as minimally invasive, motion-preserving alternatives for patients with radiculopathy due to foraminal compression [5,6]. Among these, the translaminar contralateral endoscopic foraminotomy (TCEF) approach allows for direct visualisation and precise neural decompression of the L5 nerve root without compromising segmental stability, offering faster recovery, less postoperative pain, and significant reduction in hospital stay [7-9]. The authors report a video technical note on a TCEF in a 39-year-old male with four years of worsening L5 radiculopathy and low back pain. MRI demonstrated a bilateral pars defect with low-grade spondylolisthesis, severe foraminal stenosis and annular bulging (Fig. 1). Under general anaesthesia, fluoroscopic guidance confirmed the L5-S1 level and contralateral translaminar entry point, and a 10-mm incision was made just lateral to the midline. A dilator was advanced to the L5 lamina (Fig. 2A), followed by placement of a 10-mm working cannula (Fig. 3A and B) and stenosis scope. A small laminotomy under the L5 spinous process and lamina was performed, creating a wider working corridor within the canal and providing access to the epidural space and contralateral L5-S1 foramen (Fig. 2B, C and 3C). A 30° endoscope provided high-definition magnified visualization, facilitating precise discectomy and decompression of the L5 nerve root using endoscopic graspers, rongeurs, and radiofrequency probes (Fig. 3E-G). The incision was closed with a single subcutaneous suture and the procedure was completed in 53 min with estimated blood loss of <1 cc. Postoperative imaging confirmed adequate decompression and preservation of the facet joint. Early clinical outcomes demonstrated the patient had resolution of radicular symptoms and no neurological complications. Across three performed cases, the TCEF technique was associated with rapid recovery, less than 24-h length of stay (two of three patients discharged the same day), and preservation of spinal stability. This highlights the advantages of TCEF as a non-fusion alterative for L5-S1 foraminal decompression as it provides enhanced visualization of the foraminal corridor, enables precise discectomy and minimises the risk of iatrogenic instability [7,11,12]. Furthermore, its versatility makes it suitable for a wide range of herniation morphologies at the L5-S1 level [1,9,10].

10 April 2026 in Surgical Neurology International
Verified
Journal Article
Open access
CHChris Huang
Chris Huang
RMRalph Mobbs
Ralph Mobbs
AMAlison Ma
Alison Ma
ECErin Cook
Erin Cook
Background: Postoperative neurological disturbance after endoscopic lumbar discectomy is rare. Proposed mechanisms include dural breach, irrigation-pressure transmission into the cerebrospinal fluid (CSF) space, pneumocephalus, and chemical or inflammatory irritation. As utilization of uniportal systems with continuous irrigation increases, recognizing these interactions is increasingly important. Case Description: A 29-year-old man underwent uniportal endoscopic L5/S1 discectomy for left S1 radiculopathy. No durotomy was identified intraoperatively, and irrigation pressures were maintained between 25 and 40 mmHg. Four hours postoperatively, he developed acute confusion and a generalized tonic-clonic seizure. Computed tomography brain demonstrated intracranial pneumocephalus without hemorrhage, consistent with retrograde air entry through an unrecognized dural defect facilitated by pressure fluctuations and operative gas production. He was managed with supportive care, head elevation, supplemental oxygen, and a single loading dose of levetiracetam, with no further seizures. Cognition normalized within 24 h, and radicular symptoms resolved. Persistent postural headaches prompted re-intervention on day 7, where a small, contained durotomy adjacent to the traversing nerve root was identified and repaired endoscopically, resulting in complete symptom resolution. Conclusion: Although uncommon, acute confusion, seizure, and pneumocephalus may occur following endoscopic lumbar discectomy when dural injury allows pressure transmission or air ingress into the CSF compartment. Prompt neurological assessment, urgent imaging, and short-term monitored care support excellent outcomes. As endoscopic spine surgery continues to expand, understanding the interaction between irrigation dynamics, dural integrity, and intracranial physiology is essential for early recognition and prevention of this complication.

15 August 2025 in Journal of Clinical Neuroscience
Verified
Journal Article
Open access
RMRalph J. Mobbs
Ralph J. Mobbs
AMAlison Ma
Alison Ma
CHChris Huang
Chris Huang