Mohammed Jasim M. Hassan

Mohammed Jasim M. Hassan

Auto-generated profile, based on publicly available information

Mohammed Jasim M. Hassan

Department of Chemistry, College of Science, Mustansiriyah university Baghdad, Iraq

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 November 2015 in Karbala International Journal of Modern Science
Verified
Journal Article
Open access
MHMohammed Jasim M. Hassan
Mohammed Jasim M. Hassan
WKWijdan Shakir Khayoon
Wijdan Shakir Khayoon
SHShrouq Abdul-Fatah Hasssan
Shrouq Abdul-Fatah Hasssan
A batch and flow injection (FI) spectrophotometric methods are described for the determination of barbituric acid in aqueous and urine samples. The method is based on the oxidative coupling reaction of barbituric acid with 4-aminoantipyrine and potassium iodate to form purple water soluble stable product at λ 510 nm. Good linearity for both methods was obtained ranging from 2 to 60 μg mL−1, 5–100 μg mL−1 for batch and FI techniques, respectively. The limit of detection (signal/noise = 3) of 0.45 μg mL−1 for batch method and 0.48 μg mL−1 for FI analysis was obtained. The proposed methods were applied successfully for the determination of barbituric acid in tap water, river water, and urine samples with good recoveries of 99.92% and 100.67% for batch and FI method, respectively

20 August 2019 in International Journal of Drug Delivery Technology
Verified
Journal Article
Closed access
PDF file
NANisreen Kais Abood
Nisreen Kais Abood
MHMohammed Jasim M Hassan
Mohammed Jasim M Hassan
AAAmy Muneer A Al-Da
Amy Muneer A Al-Da
TThree methods study in this research simple, sensitive, an expensive and rapid Oxidative Coupling reaction, Cloud Point Extraction and Flow Injection spectrophotometric methods for determination Methyldopa and Salbutamol, the first method oxidative coupling reaction between the Methyldopa and thiosemicarbazide in presence of ferric nitrate anhydrous to yield dark green colored product that have absorbance at λ max 460 nm. Salbutamol coupling reaction with 4-nitrophenyl hydrazine in presence the potassium Iodide and sodium hydroxide to product the violet colored has absorbance at λ max 530 nm. Beer’s law is obeyed from (1-50) µg/ mL with sandall’s sensitivity (0.039,0.073), correlation coefficient (0.9998) and molar absorptivity (0.536×104,0.327×104) for Methyldopa and Salbutamol respectively. The secondly method to estimation the trace amount of phenolic drugs that product from the oxidative coupling reaction it is cloud point extraction, cloud point extraction enables the drugs to be precisely estimated under the optimal experimental conditions, the maximum absorption at λ max (470,535) nm respectively. The concentration was range (0.25-6) µg/mL, molar absorptivity 0.510×105 ,0.483×105 and enrichment factor (9.51,14.72) respectively for Methyldopa and Salbutamol.Flow injection analysis is simple method to determination the phenolic is based on the measurement of absorption signal for product resulting from oxidative coupling reaction , study all experimental parameters chemical and physical to development and stability the colored of product .Total flow injection of 1.5mL/min was pumped and active material was detect at λ max (460,530)nm respectively for Methyldopa and Salbutamol . In this the proposed methods were suxciffuly, applied to the determination Methyldopa and Salbutamol in pharmaceutical preparation.

30 September 2023 in Al-Mustansiriyah Journal of Science
Verified
Journal Article
Open access
PDF file
AKAkram Mohsin Kadhim
Akram Mohsin Kadhim
RARana Afif Anaee
Rana Afif Anaee
MHMohammed Jasim M. Hassan
Mohammed Jasim M. Hassan
MAMunaf Adnan Idan Al-Lami
Munaf Adnan Idan Al-Lami
Corrosion is one of the most important problems that face the petroleum industry, both production and refining, and cause damage to petroleum equipment, tanks, and transmission lines, and increasing maintenance costs. in this study , was adding six concentrations of the drug expired Cefoperzone (Exp CEF) (50, 100, 200, 300, 400, and 500 ppm) to a Simulated Oil Well Water (SOWW), the inhibitive role of (Exp CEF) drug was investigated to Reduce the corrosion risk of carbon steel. Four different temperatures were used to conduct electrochemical tests (303, 313, 323 and 333 K) to achieve the study. The study was then supported by an examination of the inhibited surface using field emission scanning electron microscopy with energy dispersive (FESEM) and (AFM). The results indicated occurring the inhibition by an anodic inhibitor that controls the dissolution of iron from steel gave the highest inhibition efficiency (IE%) by adding 500 ppm, while the calculation of polarization resistance (Rp) gave the highest resistance by 400 ppm through adsorption the added drug to show flakes shaped structures with decreasing surface roughness (Ra ) from 307.1 to 83.15 after inhibition. The calculation of adsorption isotherm confirmed the obeying of Langmuir adsorption isotherm by giving the coefficient of linear regression was about one in the range of 0.999 > R^2 > 0.995, with the spontaneous adsorption that estimated from the negative values of 〖∆H〗_ads^o and variation in the type of adsorption to be physically or chemically according to the added concentration because of the differential sign of 〖∆H〗_ads^o . The sign of 〖∆H〗_ads^o was positive that reflecting the increase in randomness at the metal/solution interface.

1 June 2023 in Baghdad Science Journal
Verified
Journal Article
Open access
PDF file
HAHuda Abdulkareem
Huda Abdulkareem
MHMohammed Jasim M Hassan
Mohammed Jasim M Hassan
تم وصف تقنيتين طيفيتين لقياس كمية السيفتازيديم (CFT) في الأدوية والتركيبات الصيدلانية. فهي بسيطة وحساسة وانتقائية ودقيقة وفعالة. يستخدم الأسلوب الأول وسيطًا قلويًا لتحويل السيفتازيديم إلى ملح الديازونيوم ، والذي يتم دمجه بعد ذلك مع كواشف1-Naphthol (1-NPT) و2)2-Naphthol-NPT). تم إنتاج صبغة الآزو باللونين البني والأحمر ، مع كثافة امتصاص تصل إلى ƛmax 585nm and max 545nm ، على التوالي. تم اتباع قانون بير من حيث مدى التركيز (3-40) لـ (CFT-1-NPT) و (CFT-2 NPT) ، كانت حدود الكشف 1.0096 and 0.8017 g.ml-1على التوالي ، وكانت الامتصاصية المولية 0.7926×104 and 0.5466×104 L.mol1cm-1. 0تُستخدم طريقة تحليل حقن التدفق (FIA) لتقدير السيفتازيديم وتسجيل القياسات باستخدام نهج الأشعة فوق البنفسجية المرئية في الإجراء الثاني. يسمح حقن التدفق بتقدير دقيق للعقار في ظل ظروف تجريبية مثالية. كانت التركيزات في نطاق(3-50) لـ (CFT-1-NPT) و (CFT-2-NPT) ، وكانت حدود الكشف0.8102, 1.2809g.ml-1 . ، والامتصاصية المولية 0.9565×104 ,0.7106×104 L.mol-1. cm-1, على التوالي تم استخدام الأسلوبين المقترحين لتقدير السيفتازيديم في المستحضرات الصيدلانية بنجاح حيث تميزت هذه الطريقة بالبساطة والسرعة والدقة والتكلفة المنخفضة.

15 May 2022 in Egyptian Journal of Chemistry
Verified
Journal Article
Closed access
AFAyad Kadhim Fadhil
Ayad Kadhim Fadhil
ARAshraf Rasheed
Ashraf Rasheed
MHMohammed Jasim M. Hassan
Mohammed Jasim M. Hassan
ICInternational Marshes Research Center
International Marshes Research Center
Liquid Chromatography as a separation tool has made significant strides in a systematic study. The most widely used chromatographic process is reverse-phase liquid chromatography (RPLC), which uses polar mobile and hydrophobic stationary phases. However, specific polar composites are challenging to study using this approach. Normal-phase liquid chromatography (NPLC) is another separation process that uses polar stationary phase and organic eluents. When analyzing polar compounds, NPLC produces asymmetric chromatographic peak forms and low-efficiency separations. HILIC is a promising alternative approach for polar compound analysis. HILIC is a separation process that blends the stationary phases of the NPLC method with the mobile phase of the RPLC technique. Hydrophilic interaction liquid chromatography (HILIC) was used to separate small molecules, medicinal compounds, metabolites, contaminants, sugars, peptides, oligosaccharides, proteins, and amino acids, among other liquid chromatographic separations. Tiny polar composites can be efficiently separated on polar stationary phases using HILIC. The target of the study was to look at the different ways to characterize HILIC stationary phases and how they can be used to separate polar compounds in complex matrices. Since processes other than hydrophilic partitioning may exist, the features of the hydrophilic stationary phase may influence in some situations, restricting the selections of ion intensity, mobile phase construction, and buffer pH value available. Increasing our knowledge of HILIC retention activity broadens the range of liquid chromatography applications. HILIC systems bio uses are also discussed. This paper gives a broad description of how HILIC has been used in pharmaceutical testing in various sample matrices, including plasma, pharmaceutical dosage forms, environmental samples, serum, plant origin samples, and animal origin samples. This study also reflects on the most modern and a selection of papers in pharmaceutical science from 1991 to the suggestion deadline in 2020, which deal with examining various mechanisms using HILIC.