Phillip J. Rossman

Phillip J. Rossman

Auto-generated profile, based on publicly available information

Phillip J. Rossman

From the Departments of Radiology (A.A., M.C.M., H.B., S.P.A., P.J.R., J.D.T., K.G., Y.S., A.M., K.K., R.L.E., P.A.A.), Quantitative Health Science (T.G.), and Cardiology (A.M.A.O.), Mayo Clinic, 200 First St SW, Rochester, MN 55905

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2007 in Clinical Gastroenterology and Hepatology
Verified
Journal Article
Closed access
MYMeng Yin
Meng Yin
JTJayant A. Talwalkar
Jayant A. Talwalkar
KGKevin J. Glaser
Kevin J. Glaser
AMArmando Manduca
Armando Manduca
RGRoger C. Grimm
Roger C. Grimm
RERichard L. L Ehman
Richard L. L Ehman

1 May 2024 in Radiology
Verified
Journal Article
Closed access
EOEfe Ozkaya
Efe Ozkaya
PKPaul Kennedy
Paul Kennedy
JCJun Chen
Jun Chen
OBOctavia Bane
Octavia Bane
JDJonathan R Dillman
Jonathan R Dillman
BTBachir Taouli
Bachir Taouli
MR elastography demonstrated excellent stiffness measurement precision and test-retest repeatability across five study centers, 10 scanners, three manufacturers, two field strengths, two MR elastography sequences, and three phantoms mimicking different degrees of liver stiffness.

30 December 2015 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
EBEphraim I. Ben-Abraham
Ephraim I. Ben-Abraham
JCJun Chen
Jun Chen
JFJoel P. Felmlee
Joel P. Felmlee
PRPhil Rossman
Phil Rossman
AMArmando Manduca
Armando Manduca
RERichard L. L Ehman
Richard L. L Ehman

31 January 2013 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
LXlei xu
lei xu
JCJun Chen
Jun Chen
KGKevin J. Glaser
Kevin J. Glaser
MYMeng Yin
Meng Yin
PMPhillip J. Rossman Ms
Phillip J. Rossman Ms
RERichard L. L Ehman
Richard L. L Ehman
Purpose To investigate the feasibility of using MR elastography (MRE) for the evaluation of the stiffness of in vivo aortic wall. Materials and Methods To validate the experimental approach for imaging the aorta in vivo, a gel phantom with an embedded porcine aorta was imaged in the presence of fluid flow within the aorta. The potential changes in the elasticity of the vessel wall with changes in pressure were investigated. The feasibility of performing MRE of abdominal aorta was assessed in five volunteers (age, 22–40 years; body mass index, 21.5–25.2 kg/m2). The pulse‐gated cine MRE technique was used to study the wave propagation along the aorta throughout the cardiac cycle and provide estimates of aortic stiffness in diastole. Results In the phantom study, the wave propagation was well visualized within the porcine aorta embedded in the gel phantom. An increase of the Young's modulus‐wall thickness (E*t) product with the increase in static pressure was observed. In the in vivo study, the waves were well visualized within the lumen of abdominal aorta in the five volunteers in diastolic phase, but they were not well visualized during systole. Conclusion MRE is feasible for noninvasively assessing the stiffness of the abdominal aorta and merits further investigation. J. Magn. Reson. Imaging 2013;38:1549–1553.

1 June 2024 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Open access
AAArvin Arani
Arvin Arani
MMMatthew C. Murphy
Matthew C. Murphy
Huzefa BhopalwalaHuzefa Bhopalwala
Huzefa Bhopalwala
Shivaram P. ArunachalamShivaram P. Arunachalam
Shivaram P. Arunachalam
PRPhillip J. Rossman
Phillip J. Rossman
PAPhilip A. Araoz
Philip A. Araoz
Purpose To investigate the feasibility of using quantitative MR elastography (MRE) to characterize the influence of aging and sex on left ventricular (LV) shear stiffness. Materials and Methods In this prospective study, LV myocardial shear stiffness was measured in 109 healthy volunteers (age range: 18-84 years; mean age, 40 years ± 18 [SD]; 57 women, 52 men) enrolled between November 2018 and September 2019, using a 5-minute MRE acquisition added to a clinical MRI protocol. Linear regression models were used to estimate the association of cardiac MRI and MRE characteristics with age and sex; models were also fit to assess potential age-sex interaction. Results Myocardial shear stiffness significantly increased with age in female (age slope = 0.03 kPa/year ± 0.01, P = .009) but not male (age slope = 0.008 kPa/year ± 0.009, P = .38) volunteers. LV ejection fraction (LVEF) increased significantly with age in female volunteers (0.23% ± 0.08 per year, P = .005). LV end-systolic volume (LVESV) decreased with age in female volunteers (-0.20 mL/m2 ± 0.07, P = .003). MRI parameters, including T1, strain, and LV mass, did not demonstrate this interaction (P > .05). Myocardial shear stiffness was not significantly correlated with LVEF, LV stroke volume, body mass index, or any MRI strain metrics (P > .05) but showed significant correlations with LV end-diastolic volume/body surface area (BSA) (slope = -3 kPa/mL/m2 ± 1, P = .004, r2 = 0.08) and LVESV/BSA (-1.6 kPa/mL/m2 ± 0.5, P = .003, r2 = 0.08). Conclusion This study demonstrates that female, but not male, individuals experience disproportionate LV stiffening with natural aging, and these changes can be noninvasively measured with MRE. Keywords: Cardiac, Elastography, Biological Effects, Experimental Investigations, Sexual Dimorphisms, MR Elastography, Myocardial Shear Stiffness, Quantitative Stiffness Imaging, Aging Heart, Myocardial Biomechanics, Cardiac MRE Supplemental material is available for this article. Published under a CC BY 4.0 license.

11 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KMKiaran McGee
Kiaran McGee
NCNorbert G. Campeau
Norbert G. Campeau
RWRobert J. Witte
Robert J. Witte
PRPhilip J. Rossman
Philip J. Rossman
JCJackie A. Christopherson
Jackie A. Christopherson
FRFraser Robb
Fraser Robb
Purpose: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. Methods: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. Results: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. Conclusions: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.