17 August 2023 in IEEE Transactions on Power Electronics
The Phase-locked loop (PLL) is widely used to synchronize the converters with the grid. However, the asymmetric dynamic characteristics of the PLL may cause frequency coupling effects and even cause sub/super synchronous oscillation in weak grids. This paper analyzes the frequency coupling effects of the conventional dual second-order generalized integrator (DSOGI) PLL. A novel PLL structure is proposed to eliminate the frequency-coupling effects, simultaneously controlling the d-axis and q-axis voltage components. The inter-harmonic components can be suppressed, and the perturbation propagation paths through the PLL can be prevented. In this way, the synchronization stability of converters under weak grids is improved. Also, the design procedure of the structure and parameters of the PLL are provided. Finally, the simulations and experimental results verify the effectiveness of the proposed solution.
21 November 2023 in IEEE Transactions on Industrial Electronics
Due to the potential for high power density and high efficiency, the high-frequency link matrix converter has been increasingly used in power conversion. However, there is a large voltage difference on the leakage inductance of the high frequency transformer, resulting in high current stress. High current stress will reduce hardware utilization, increase costs, and reduce efficiency. To optimize the operation of the high-frequency link matrix converter, the control method of H-bridge duty cycle variable by adjusting the modulation index and phase shift angle is proposed in this article to keep converter in the lowest current stress state. Then, to obtain the combination of phase shift angle and modulation index at different powers, a mathematical model of the transferred power is established based on the sector division of space vector modulation. Experimental results on a high-frequency link matrix converter are provided to verify the effectiveness of the proposed method.
22 August 2024 in IEEE Transactions on Power Electronics
In order to improve the reliability of current source converters, a new fault diagnosis method that can identify the single-switch and double-switch short-circuit faults is proposed in this article. It only needs an output current signal. First, the amplitude and phase of the output current vector are calculated in a real-time manner. Second, the amplitude is compared with a diagnosis threshold. Combined with the phase information, the switch that has a short-circuit fault can be detected and located. The method is simple to achieve, which can be implemented in the existing control program directly. No additional sensors or other auxiliary equipment are needed. Compared with the existing fault diagnosis methods, the detection speed is faster and the implementation is simpler. Experimental results are presented to verify the effectiveness of the proposed solution.
22 January 2024 in IEEE Transactions on Industry Applications
Transformerless inverters are used in small and medium power photovoltaic grid-connected systems due to smallsize, low-cost and high-efficiency. Transformerless inverters have problems of leakage current and low-voltage gain in applications due to the lack of electrical isolation and boost characteristics of transformers. According to these problems, this paper introduces a gain unit circuit in the front-stage based on the two-stage topology of Boost converter combined with the H-bridge inverter to improve the boost capability. In addition, the rear-stage converter adopts double Buck inverter, which has the ability to prevent the short circuit of the bridge arms and improves the reliability of the system. At the same time, it is ensured that there is no high-frequency component in the parasitic capacitor voltage, and the leakage current is suppressed. In this paper, the operational modes, circuit gain, devices stress and loss calculation of the proposed inverter are analyzed. Finally, an experimental platform is built to verify the effectiveness of the proposed circuit.
1 January 2025 in IEEE Transactions on Instrumentation and Measurement
22 March 2024 in IEEE Transactions on Industrial Electronics
In order to effectively eliminate the overlap-time effect introduced by the addition of the overlap time in the space vector modulation (SVM), an overlap-time effect elimination SVM method based on vector bridge extension is proposed for current source converter (CSC). This article first selects the current vector as the bridge vector according to the ac side voltage relationships, and then uses the bridge vector to add the overlap time to the other two current vectors by bridge extension method, which make the dwell time of active vector the same as the ideal dwell time and the overlap-time effect can be directly eliminated without any compensation. In addition, by rearranging the order of the vectors, the number of switching times is reduced. Thus, this method sets the overlap time within the modulation, which is different from the traditional SVMs. The output current is the same as that of the ideal SVM, which can improve the harmonic performance of currents. Finally, the simulation and experimental results show that the proposed method can effectively eliminate the overlap-time effect.