This paper presents a dynamic modeling approach to analyze pollution flashover of silicone rubber insulators. Pre-flashover conditions can be used to represent analytical formulations for different stages of dry band arcing activities on the surface of polluted insulator. In this paper, effects of dust deposit as non-soluble deposit density (NSDD) are investigated on dynamic behavior of partial arcs on surface of insulators by means of a proposed multi-arcs modeling approach. It is shown that analytical formulations of dynamic resistance of surface pollution can be used to analyze different mode of arcing as unstable and stable. Real data of leakage current (LC) and flashover voltage (FOV) of polluted insulator are used to make correlation with analytical multi-arcs formulations. The proposed analytical multi-arcs model is based on an artificial neural network (ANN) which is able to predict the LC and FOV of the insulator in real-time monitoring. In addition, effects of pollution resistance as variable surface conduction and thickness of pollution layer are investigated on LC and FOV of the insulators. It is shown that the proposed multi-arcs representation has a closer correlation with real testing data in comparison of previous single-arc and multi-arcs models.
16 September 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
In this article, a novel dynamic approach is proposed to analyze pollution layer resistance of polymer insulators. One of the main challenges in dynamic modeling of pollution layer resistance is the effects of pollution layer conduction and pollution layer thickness on discharge length due to change in pollution layer thickness and wetting rate in real outdoor conditions. The represented approach investigates the effects of such parameters on variation of discharge length. Then, an artificial intelligence (AI) algorithm based on artificial neural network (ANN) is developed to predict flashover voltage (FOV) of polluted insulators according to the prediction of critical discharge length. Calculations are done based on experimental data of leakage current (LC) and voltage of insulators in different pollution conditions. Obtained results by the proposed approach show a close correlation with experimental results. In addition, various validation tests are performed to investigate the effects of hydrophobicity class (HC) of polymeric surface and pollution type on the quality of the represented analysis. Results of the validation also show a close correlation between calculations and real data.
19 November 2021 in IEEE Transactions on Power Delivery
This research presents a dynamic modeling approach to predict flashover voltage (FOV) of polymer insulators. Pre-flashover conditions can be used to represent analytical formulations for different stages of dry band arcing activities on the surface of polluted insulator. In this study, experimental results of pollution flashover tests are used to develop a circuit model of pollution arcs based on Obenaus’ model. Estimation of circuit values is done by use of intelligent algorithm with no dependency on profile of insulators which is also more beneficial than typical analytical calculations. Then, separation and investigation of discharge and pollution voltage is done and proper classification is made. This classification is later used to predict pre-flashover conditions and pollution flashover. Gaussian model is used to make fitness of voltage of pollution layer and voltage of discharge on the surface of insulator. Gaussian representation of each stage in pollution flashover contains critical signals leading to complete discharge. Based on the obtained model, a flowchart is presented to predict dynamic stages of flashover. Comparison to various experimental data shows close correlations with the results of proposed model. An online monitoring system can be developed according to obtained results in order to prevent pollution flashover.
The hosting capacity of solar photovoltaics (PVs) in the distribution network can be impacted by the violation of power flow constraints such as power loss, voltage, and line loadings. In this paper, a planning structure based on optimal PV placement and optimal operation of the smart inverters and soft open point (SOP) is proposed in order to investigate the loss of power, voltage profiles, line loadings and total operation cost of the distribution system. The stochastic nature of the daily load and PV generation is considered in power flow optimization by the proposed method. Respective objective functions are optimized using a genetic algorithm (GA) according to probabilistic power flow. While the desired objective function is optimized, the optimality of the PV locations and contribution of smart inverters and SOP is ensured through GA optimization. The proposed model is investigated through numerical analyses on IEEE 33‐bus and IEEE 69‐bus distribution systems considering different cases of reactive power supports. Developed GA is able to deal with challenges of convergence that are imposed by complex nonlinear formulations. Obtained results prove the superiority of the developed program for the investigation of the PV hosting capacity in both technical and cost aspects.