27 November 2019 in Photonics Research
The scattering medium is usually thought to have a negative effect on the imaging process. In this paper, it is shown that the imaging quality of reflective ghost imaging (GI) in the scattering medium can be improved effectively when the binary method is used. By the experimental and the numerical results, it is proved that the existence of the scattering medium is just the cause of this phenomenon, i.e., the scattering medium has a positive effect on the imaging quality of reflective GI. During this process, the effect from the scattering medium behaves as the random noise which makes the imaging quality of binary ghost imaging have an obvious improvement.
23 July 2023 in Optics & Laser Technology
13 July 2023 in Physical Review Applied
A label-free, low-photodamage, low-cost, and in vivo high-resolution microscopic imaging technique has been challenging to develop. Ghost imaging (GI) is a computational imaging protocol with the spatially nonlocal property, which enables low-light imaging. Considering the advantages of GI, we propose a method, called high-resolution microscopic ghost imaging (HRMGI), to achieve high-resolution imaging by simply demagnifying the signal beam. The analytical formulas for resolution and depth of field (DOF) of HRMGI are provided. Experimental results show that the HRMGI system can have 10.5 times higher resolution than the conventional GI, which can exceed the pixel size limit of multipixel detectors, and 58 times greater DOF than the traditional diffraction-limited optical (TDLO) system. To present the performance of HRMGI, blood vessels within an ovarian section are also imaged. The proposed method is expected to facilitate the development of bioimaging techniques and promote the practical application of GI.
28 October 2016 in Optics Express
The point-spread function (PSF) is fundamental importance in estimating the imaging resolution in optical imaging systems. By using the Collins formula, a analytical imaging formula for ghost imaging system is obtained. The intensity fluctuation correlation function can be viewed as the convolution of the original object and a PSF. The imaging resolution is determined by the width of PSF. Based on the optical transfer matrix theory, we present the analytical formula describing the width of the PSF, by which one can estimate imaging resolution of a new-designed imaging scheme when compared with that of the existing imaging system. Several typical ghost imaging systems are chosen to verify experimentally our theoretical results.
1 January 2021 in Chinese Optics Letters
Typical single-pixel imaging techniques for edge detection are mostly based on first-order differential edge detection operators. In this paper, we present a novel edge detection scheme combining Fourier single-pixel imaging with a second-order Laplacian of Gaussian (LoG) operator. This method utilizes the convolution results of an LoG operator and Fourier basis patterns as the modulated patterns to extract the edge detail of an unknown object without imaging it. The simulation and experimental results demonstrate that our scheme can ensure finer edge detail, especially under a noisy environment, and save half the processing time when compared with a traditional first-order Sobel operator.
21 April 2023 in Optics Express
Research towards practical applications of ghost imaging lidar system especially in longer sensing distance has been urgent in recent years. In this paper we develop a ghost imaging lidar system to boost an extension of remote imaging, where the transmission distance of the collimated pseudo-thermal beam can be improved hugely over long range and just shifting the adjustable lens assembly generates wide field of view suiting for short-range imaging. Based on the proposed lidar system, the changing tendency of illuminating field of view, energy density, and reconstructed images is analyzed and verified experimentally. Some considerations on the improvement of this lidar system are also discussed.