18 June 2024 in IEEE Robotics and Automation Letters
Large Language Models (LLMs) are gaining popularity in the field of robotics. However, LLM-based robots are limited to simple, repetitive motions due to the poor integration between language models, robots, and the environment. This letter proposes a novel approach to enhance the performance of LLM-based autonomous manipulation through Human-Robot Collaboration (HRC). The approach involves using a prompted GPT-4 language model to decompose high-level language commands into sequences of motions that can be executed by the robot. The system also employs a YOLO-based perception algorithm, providing visual cues to the LLM, which aids in planning feasible motions within the specific environment. Additionally, an HRC method is proposed by combining teleoperation and Dynamic Movement Primitives (DMP), allowing the LLM-based robot to learn from human guidance. Real-world experiments have been conducted using the Toyota Human Support Robot for manipulation tasks. The outcomes indicate that tasks requiring complex trajectory planning and reasoning over environments can be efficiently accomplished through the incorporation of human demonstrations.
21 March 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
We have been developing the robotic wear curara® as both a welfare device and rehabilitation robot that assists the elderly and disabled. curara® is aimed at user friendliness. We have thus chosen a non-exoskeleton structure made of a plastic so that the robot is as light in weight as possible and to minimize the restraining stress against natural human movement. We verified the assistance effect of curara® on 15 hemiplegic patients with stroke by comparing gait parameters (i.e., velocity, step length, cadence, and symmetry of joint angles) among three conditions. The conditions were “without assistance” (i.e., a control mode that cancels frictional resistances in actuators), Condition A (where joint angles are enlarged but there is no change in gait cycle), and Condition B (where there is no change in joint angles but the gait cycle is shortened). curara® improved the walking velocity by 19% and 27% under Conditions A and B, respectively. Improvements in step length and cadence were respectively 11% and 7% under Condition A and 14% and 11% under Condition B. Moreover, the two assistance conditions reduced the difference in joint angles between unaffected and paralyzed legs. We consider that curara® will facilitate the rehabilitation of stroke patients.
19 September 2018 in Journal of NeuroEngineering and Rehabilitation
Spinocerebellar degeneration (SCD) mainly manifests a cerebellar ataxic gait, leading to marked postural sway and the risk of falling down. Gait support using a wearable robot is expected to be an effective solution to maintaining the status quo and/or delaying symptom progression. The aim of this study was to evaluate the effects of gait support in patients with SCD by using a wearable robotic system called curara ®; while undergoing walking tests. The curara system assists both the hip and knee joints and supports the wearer’s rhythmic gait using a synchronization control based on a central pattern generator. The system reflects the wearer’s intended motion in response to the gait support by detecting an interactive force that is generated from slight movements of the wearer. The degree of coordinated motion between the robot and the wearer can be adjusted by modifying the synchronization gain. In this study, we provided gait support using three high-gain conditions (A, B, C) to more easily follow the wearer’s movement in each joint. The synchronization gains for both the hip and knee joints (i.e., Ch and Ck) were set at 0.5 for condition A and at 0.4 for condition B. Condition C had different gains for the hip and knee joints (i.e., Ch=0.4 and Ck=0.5). With the walking test, we assessed the effects of the gait support provided by the curara system on walking smoothness (measured using the harmonic ratio: HR) and spatiotemporal parameters (gait speed, stride length, cadence) in SCD patients (n=12). We compared the performance between the three high-gain conditions and without assistance from the robot. Under condition C, the HRs in the anteroposterior, mediolateral, and vertical directions (HR-AP, HR-ML, and HR-V) were especially high compared with those under conditions A and B. The results of the statistical analyses using repeated measures analysis of variance followed by Tukey’s test showed that gait support with condition C results in a statistically significant increase in the HR-AP (2.04 ±0.52; p=0.025) and HR-V (2.06 ±0.37; p=0.032) when compared with walking without assistance from the system. In contrast, the gait speed, stride length, and cadence under condition C were no major changes in most patients, compared with the patient’s walking without assistance. The significantly increased HR indicates that gait support under condition C achieved smoother walking than when not wearing the power unit of the system. Consequently, we suggest that gait support using the curara system has the potential to improve walking smoothness in patients with SCD.
25 August 2025 in IEEE Access
Our previous work introduced motor-driven Variable Grounding Flexible Limbs (VGFLs) that assist users' sit-to-stand (STS) and stand-to-sit (SIT) transfers by dynamically adjusting their ground contact positions. Building upon this concept, this study proposes crutch-integrated VGFLs actuated by a fully passive mechanism, eliminating the need for powered actuators or onboard batteries, and assesses the functionality of the VGFLs through verification experiments involving healthy subjects simulating a forward-leaning posture. The proposed VGFLs incorporate a passive power unit consisting of constant-force spiral springs, which transmit mechanical energy to the VGFLs via braided polymer lines. This configuration produces bidirectional coiling and uncoiling motions, generating a vertical assistive force during STS and SIT transfers. A functionality assessment of the VGFLs was conducted by comparing users' STS and SIT transfers under the VGFL-assisted condition with those under three other conditions (no support, short crutches, and long crutches), based on the root mean square (RMS) values of the center of mass (CoM) acceleration and the peak-to-peak amplitudes of surface electromyography (sEMG) signals. The STS and SIT transfer assistance provided by the VGFLs resulted in statistically significant reductions in CoM acceleration RMS and quadriceps sEMG activity, specifically in one or more of the rectus femoris, vastus medialis, and vastus lateralis muscles, in several subjects compared to the control conditions. These findings suggest that crutch-integrated VGFLs can enhance postural stability and reduce lower limb muscle loading during STS and SIT transfers, potentially improving transfer performance in daily living.