2 October 2006 in IEEE Transactions on Industrial Electronics
This paper presents a novel approach for the connection of renewable energy sources to the utility grid. Due to the increasing power capability of the available generation systems, a three-level three-phase neutral-point-clamped voltage-source inverter is selected as the heart of the interfacing system. A multivariable control law is used for the regulator because of the intrinsic multivariable structure of the system. A current source (playing the role of a generic renewable energy source) is connected to the grid using a three-level inverter in order to verify the good performance of the proposed approach. Large- and small-signal d-q state-space averaged models of the system are obtained and used to calculate the multivariable controller based on the linear quadratic regulator technique. This controller simultaneously regulates the dc-link voltage (to operate at the maximum power point of the renewable energy source), the mains power factor (the power is delivered to the grid at unity power factor), and the dc-link neutral-point voltage balance. With the model and regulator presented, a specific switching strategy to control the dc-link neutral-point voltage is not required. The proposed controller can be used for any application, since its nature makes possible the control of any system variable. The good performance of the presented interfacing solution in both steady-state and transient operation is verified through simulation and experimentation using a 1-kW neutral-point-clamped voltage-source-inverter prototype, where a PC-embedded digital signal processor board is used for the controller implementation
12 November 2007 in IEEE Transactions on Power Electronics
JBJean-Charles Le Bunetel
+1
Spread spectrum clock generation techniques were originally developed to reduce electromagnetic interference (EMI) in communications and microprocessor systems working in the range of hundreds of megahertz. Nowadays, the switching frequency of power converters has been increasing up to values that make worthy the application of such switching frequency modulation techniques to reduce EMI emissions in power converters. Although random modulations have been applied before to power converters, periodic patterns can provide some advantages. First, theoretical principles of frequency modulation using three periodic patterns for the modulating function are presented. The influence of some important modulation parameters on the EMI reduction is analyzed and some considerations about the EMI filters design are also presented. The effectiveness of such methods in terms of EMI reduction is demonstrated theoretically and confirmed with experimental results obtained from tests carried out on two converters. The first one is a 2.5 W buck converter that can be switched up to 1 MHz and the second one is a 600 W boost converter switching at 40 kHz. In both cases, attenuations obtained in conducted EMI are evaluated. Finally, special attention has been paid to input current and output voltage ripple in order to evaluate possible undesired side-effects produced by this technique.
10 October 2005 in IEEE Transactions on Electromagnetic Compatibility
Frequency-modulation techniques have been used to reduce electromagnetic interference (EMI) produced by the clock of digital systems working in the range of hundreds of megahertz. The working principle consists of modulating the original constant clock frequency in order to spread the energy of each single harmonic into a certain frequency band, thus reducing the peak amplitude of EMI at harmonic frequencies. Nowadays, the switching frequency of power converters has increased up to values that make interesting the application of such techniques to reduce EMI emissions due to switching of power circuits. This paper presents the theoretical principles of frequency modulation using deterministic profiles for the modulating function. It shows the effectiveness of such methods in terms of EMI reduction for different modulation profiles and other parameters. The method is compared with other methods using random modulation. Tests carried out on a buck converter are presented for experimental validation of the method. A short discussion on optimal modulation profiles and parameters is also included.
19 November 2007 in IEEE Transactions on Electromagnetic Compatibility
Circuits based on operational amplifiers (OPAMPs) are susceptible to electromagnetic interference (EMI) in the radio-frequency range due to the AM demodulation produced by non-linearity of internal transistors. Such a phenomenon produces demodulated signals in the low-frequency range. This paper presents a model to predict the susceptibility of analog signal-conditioning circuits, based on a few test parameters, while ignoring the internal structure of OPAMPs involved in the circuit. The method has been experimentally tested in two applications: (1) test of simple instrumentation adapter circuits and (2) predictions of susceptibility of an amplifier for an electret microphone, tested according to EN55020.
7 September 2012 in IEEE Transactions on Industrial Electronics
In this paper, we present a new approach to evaluation of signal integrity that is based on signal energy density as a function of time and frequency, represented by its wavelet scalogram. Using signal integrity ratio and cumulative energy ratio, we illustrate signal integrity analysis with simulated examples, followed by the demonstration of their usefulness through analysis of experimental data of a real audio amplifier. These figures of merit represent the extent to which the integrity of a signal is diminished by the electromagnetic interference effects and/or nonlinear processes.