David Gonzalez

David Gonzalez

Auto-generated profile, based on publicly available information

David Gonzalez

UNIVERSITAT POLITÈCNICA DE CATALUNYA, Electronics Engineering Dpt., 08222 Terrassa, Spain

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2006 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Salvador AlepuzSalvador Alepuz
Salvador Alepuz
Sergio Busquets-MongeSergio Busquets-Monge
Sergio Busquets-Monge
JBJ. Bordonau
J. Bordonau
JGJ. Gago
J. Gago
DGD. Gonzalez
D. Gonzalez
JBJ. Balcells
J. Balcells
This paper presents a novel approach for the connection of renewable energy sources to the utility grid. Due to the increasing power capability of the available generation systems, a three-level three-phase neutral-point-clamped voltage-source inverter is selected as the heart of the interfacing system. A multivariable control law is used for the regulator because of the intrinsic multivariable structure of the system. A current source (playing the role of a generic renewable energy source) is connected to the grid using a three-level inverter in order to verify the good performance of the proposed approach. Large- and small-signal d-q state-space averaged models of the system are obtained and used to calculate the multivariable controller based on the linear quadratic regulator technique. This controller simultaneously regulates the dc-link voltage (to operate at the maximum power point of the renewable energy source), the mains power factor (the power is delivered to the grid at unity power factor), and the dc-link neutral-point voltage balance. With the model and regulator presented, a specific switching strategy to control the dc-link neutral-point voltage is not required. The proposed controller can be used for any application, since its nature makes possible the control of any system variable. The good performance of the presented interfacing solution in both steady-state and transient operation is verified through simulation and experimentation using a 1-kW neutral-point-clamped voltage-source-inverter prototype, where a PC-embedded digital signal processor board is used for the controller implementation

12 November 2007 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DGDavid Gonzalez
David Gonzalez
JBJosep Balcells
Josep Balcells
ASAlfonso Santolaria
Alfonso Santolaria
JBJean-Charles Le Bunetel
Jean-Charles Le Bunetel
JGJavier Gago
Javier Gago
SBStéphane Brehaut
Stéphane Brehaut
Spread spectrum clock generation techniques were originally developed to reduce electromagnetic interference (EMI) in communications and microprocessor systems working in the range of hundreds of megahertz. Nowadays, the switching frequency of power converters has been increasing up to values that make worthy the application of such switching frequency modulation techniques to reduce EMI emissions in power converters. Although random modulations have been applied before to power converters, periodic patterns can provide some advantages. First, theoretical principles of frequency modulation using three periodic patterns for the modulating function are presented. The influence of some important modulation parameters on the EMI reduction is analyzed and some considerations about the EMI filters design are also presented. The effectiveness of such methods in terms of EMI reduction is demonstrated theoretically and confirmed with experimental results obtained from tests carried out on two converters. The first one is a 2.5 W buck converter that can be switched up to 1 MHz and the second one is a 600 W boost converter switching at 40 kHz. In both cases, attenuations obtained in conducted EMI are evaluated. Finally, special attention has been paid to input current and output voltage ripple in order to evaluate possible undesired side-effects produced by this technique.

10 October 2005 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
JBJ. Balcells
J. Balcells
ASA. Santolaria
A. Santolaria
AOA. Orlandi
A. Orlandi
DGD. Gonzalez
D. Gonzalez
JGJ. Gago
J. Gago
Frequency-modulation techniques have been used to reduce electromagnetic interference (EMI) produced by the clock of digital systems working in the range of hundreds of megahertz. The working principle consists of modulating the original constant clock frequency in order to spread the energy of each single harmonic into a certain frequency band, thus reducing the peak amplitude of EMI at harmonic frequencies. Nowadays, the switching frequency of power converters has increased up to values that make interesting the application of such techniques to reduce EMI emissions due to switching of power circuits. This paper presents the theoretical principles of frequency modulation using deterministic profiles for the modulating function. It shows the effectiveness of such methods in terms of EMI reduction for different modulation profiles and other parameters. The method is compared with other methods using random modulation. Tests carried out on a buck converter are presented for experimental validation of the method. A short discussion on optimal modulation profiles and parameters is also included.

19 November 2007 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
JGJavier Gago
Javier Gago
JBJosep Balcells
Josep Balcells
DGDavid González
David González
MLManuel Lamich
Manuel Lamich
JMJuan Mon
Juan Mon
ASAlfonso Santolaria
Alfonso Santolaria
Circuits based on operational amplifiers (OPAMPs) are susceptible to electromagnetic interference (EMI) in the radio-frequency range due to the AM demodulation produced by non-linearity of internal transistors. Such a phenomenon produces demodulated signals in the low-frequency range. This paper presents a model to predict the susceptibility of analog signal-conditioning circuits, based on a few test parameters, while ignoring the internal structure of OPAMPs involved in the circuit. The method has been experimentally tested in two applications: (1) test of simple instrumentation adapter circuits and (2) predictions of susceptibility of an amplifier for an electret microphone, tested according to EN55020.

7 September 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JBJan T. Bialasiewicz
Jan T. Bialasiewicz
DGDavid Gonzalez
David Gonzalez
JBJosep Balcells
Josep Balcells
JGJavier Gago
Javier Gago
In this paper, we present a new approach to evaluation of signal integrity that is based on signal energy density as a function of time and frequency, represented by its wavelet scalogram. Using signal integrity ratio and cumulative energy ratio, we illustrate signal integrity analysis with simulated examples, followed by the demonstration of their usefulness through analysis of experimental data of a real audio amplifier. These figures of merit represent the extent to which the integrity of a signal is diminished by the electromagnetic interference effects and/or nonlinear processes.

8 July 2004
Verified
Conference Paper
Closed access
ASA. Santolaria
A. Santolaria
JBJ. Balcells
J. Balcells
DGD. Gonzalez
D. Gonzalez
JGJ. Gago
J. Gago
Although most of the power converters are currently designed to operate by using a constant switching frequency and a variable duty-cycle, some attempts were made in order to verify the effect of modulating the switching frequency [F. Lin et al., 1992] and how this modulation affected the power converters EMI emissions. As known, spread spectrum clock generation (SSCG) modulates the originally constant switching frequency by following a certain modulation profile in order to spread the single harmonic energy into an amount of side-band harmonics having the same energy but much smaller amplitudes. This reduction technique has been used and implemented for high frequencies (as those related to clock frequencies in communications and microprocessors systems). This paper is dedicated to SSCG applied to the reduction of EMI emissions in power converters, focusing on the effectiveness of frequency modulation in EMI reduction as a function of the different switching frequency ranges and modulation profiles. Theoretical results were obtained just modulating a sine pure wave following several modulation profiles [A. Santolaria et al., 2002], this one representing each one of the harmonics composing the real square PWM-signal controlling the power converter. A practical arrangement was implemented to generate and measure EMI emissions.