Salvador Alepuz

Dr. Salvador Alepuz

Tecnocampus Mataró-Maresme, Universitat Pompeu Fabra, 08302 Mataró, Spain
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Roberto Cárdenas-DobsonRoberto Cárdenas-Dobson
Roberto Cárdenas-Dobson
RPRubén Pena
Rubén Pena
Salvador AlepuzSalvador Alepuz
Salvador Alepuz
GAGreg Asher
Greg Asher
Doubly fed induction generators (DFIGs), often organized in wind parks, are the most important generators used for variable-speed wind energy generation. This paper reviews the control systems for the operation of DFIGs and brushless DFIGs in wind energy applications. Control systems for stand-alone operation, connection to balanced or unbalanced grids, sensorless control, and frequency support from DFIGs and low-voltage ride-through issues are discussed.

2 October 2006 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Salvador AlepuzSalvador Alepuz
Salvador Alepuz
Sergio Busquets-MongeSergio Busquets-Monge
Sergio Busquets-Monge
JBJ. Bordonau
J. Bordonau
JGJ. Gago
J. Gago
DGD. Gonzalez
D. Gonzalez
JBJ. Balcells
J. Balcells
This paper presents a novel approach for the connection of renewable energy sources to the utility grid. Due to the increasing power capability of the available generation systems, a three-level three-phase neutral-point-clamped voltage-source inverter is selected as the heart of the interfacing system. A multivariable control law is used for the regulator because of the intrinsic multivariable structure of the system. A current source (playing the role of a generic renewable energy source) is connected to the grid using a three-level inverter in order to verify the good performance of the proposed approach. Large- and small-signal d-q state-space averaged models of the system are obtained and used to calculate the multivariable controller based on the linear quadratic regulator technique. This controller simultaneously regulates the dc-link voltage (to operate at the maximum power point of the renewable energy source), the mains power factor (the power is delivered to the grid at unity power factor), and the dc-link neutral-point voltage balance. With the model and regulator presented, a specific switching strategy to control the dc-link neutral-point voltage is not required. The proposed controller can be used for any application, since its nature makes possible the control of any system variable. The good performance of the presented interfacing solution in both steady-state and transient operation is verified through simulation and experimentation using a 1-kW neutral-point-clamped voltage-source-inverter prototype, where a PC-embedded digital signal processor board is used for the controller implementation

16 March 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Salvador AlepuzSalvador Alepuz
Salvador Alepuz
Sergio Busquets-MongeSergio Busquets-Monge
Sergio Busquets-Monge
JBJosep Bordonau
Josep Bordonau
JMJuan A. Martinez-Velasco
Juan A. Martinez-Velasco
CSCésar Silva
César Silva
Jose RodriguezJose Rodriguez
Jose Rodriguez
Low-voltage ride-through (LVRT) requirements demand wind-power plants to remain connected to the network in presence of grid-voltage dips. Most dips present positive-, negative-, and zero-sequence components. Hence, regulators based on symmetrical components are well suited to control grid-connected converters. A neutral-point-clamped topology has been considered as an active front end of a distributed power-generation system, following the trend of increasing power and voltage levels in wind-power systems. Three different current controllers based on symmetrical components and linear quadratic regulator have been considered. The performance of each controller is evaluated on LVRT requirement fulfillment, grid-current balancing, maximum grid-current value control, and oscillating power flow. Simulation and experimental results show that all three controllers meet LVRT requirements, although different system performance is found for each control approach. Therefore, controller selection depends on the system constraints and the type of preferred performance features.

24 June 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Sergio Busquets-MongeSergio Busquets-Monge
Sergio Busquets-Monge
JRJoan Rocabert
Joan Rocabert
PRPedro Rodriguez
Pedro Rodriguez
Salvador AlepuzSalvador Alepuz
Salvador Alepuz
JBJosep Bordonau
Josep Bordonau
In photovoltaic (PV) power systems where a set of series-connected PV arrays (PVAs) is connected to a conventional two-level inverter, the occurrence of partial shades and/or the mismatching of PVAs leads to a reduction of the power generated from its potential maximum. To overcome these problems, the connection of the PVAs to a multilevel diode-clamped converter is considered in this paper. A control and pulsewidth-modulation scheme is proposed, capable of independently controlling the operating voltage of each PVA. Compared to a conventional two-level inverter system, the proposed system configuration allows one to extract maximum power, to reduce the devices voltage rating (with the subsequent benefits in device-performance characteristics), to reduce the output-voltage distortion, and to increase the system efficiency. Simulation and experimental tests have been conducted with three PVAs connected to a four-level three-phase diode-clamped converter to verify the good performance of the proposed system configuration and control strategy.

14 March 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Salvador AlepuzSalvador Alepuz
Salvador Alepuz
ACAlejandro Calle
Alejandro Calle
Sergio Busquets-MongeSergio Busquets-Monge
Sergio Busquets-Monge
Samir KouroSamir Kouro
Samir Kouro
BWBin Wu
Bin Wu
The increasing installed wind power capacity has caused wind power generation to become a significant percentage of the entire electric power generation. As a consequence, the power system operators have included wind power plants regulation to improve the control of the overall power system, both in steady-state and transient operation. Therefore, wind power systems are required to verify the grid connection requirements stated by the power system operators. In presence of grid voltage dips, the low voltage ride-through (LVRT) requirement compliance produces a mismatch between the generated active power and the active power delivered to the grid. The conventional solution assumes that the active power surplus is dissipated in a dc-link resistor. In this paper, a control scheme for the back-to-back neutral-point-clamped converter is proposed. Under grid voltage dip, the controllers for generator-side and grid-side converters work concurrently to meet the LVRT requirement by storing the active power surplus in the turbine-generator mechanical system inertia while keeping constant the dc-link voltage. Simulation and experimental results verify the proposed control scheme.

22 October 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
ACAlejandro Calle-Prado
Alejandro Calle-Prado
Salvador AlepuzSalvador Alepuz
Salvador Alepuz
JBJosep Bordonau
Josep Bordonau
Joan Nicolas-ApruzzeseJoan Nicolas-Apruzzese
Joan Nicolas-Apruzzese
PCPatricio Cortes
Patricio Cortes
Jose RodriguezJose Rodriguez
Jose Rodriguez
The low-voltage ride through (LVRT) requirement demands the wind power plants to remain connected to the grid in the presence of grid voltage dips, actively helping the network overall control to keep network voltage and frequency stable. Wind power technology points to increase power ratings. Hence, multilevel converters, as for example, neutral-point- clamped (NPC) converters, are well suited for this application. Predictive current control presents similar dynamic response and reference tracking than other well-established control methods, but working at lower switching frequencies. In this paper, the predictive current control is applied to the grid-side NPC converter as part of a wind energy conversion system, in order to fulfill the LVRT requirements. DC-link neutral-point balance is also achieved by means of the predictive control algorithm, which considers the redundant switching states of the NPC converter. Simulation and experimental results confirm the validity of the proposed control approach.