Haiyan Dong

Haiyan Dong

Auto-generated profile, based on publicly available information

Haiyan Dong

Hebei Key Laboratory of Power Electronics for Energy Conservation and Drive Control, School of Electrical Engineering, Yanshan University, Qinhuangdao, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2022 in IEEE Access
Verified
Journal Article
Open access
ZQZhengwei Qu
Zhengwei Qu
ZSZhe Shi
Zhe Shi
YWYunjing Wang
Yunjing Wang
Ahmed Abu-SiadaAhmed Abu-Siada
Ahmed Abu-Siada
ZCZhenxiao Chong
Zhenxiao Chong
HDHaiyan Dong
Haiyan Dong
Voltage fluctuation and power mismatch which are caused by the decentralization, randomness, and intermittence of distributed energy resource along with load variability cause severe impacts on the security and quality of power network operation. Aiming at alleviating this issue, the structure of an AC/DC hybrid microgrid based on solid-state transformer is presented in this paper. A proper control coordination is developed to guarantee stable and reliable operation of the system. An energy management strategy is proposed to coordinate the power flow among the solid-state transformer, AC microgrid, DC microgrid and energy storage and to effectively suppress the fluctuation of the DC bus voltage. A novel adaptive droop control for the energy storage is proposed to prolong the supercapacitor life and achieve an optimum economic benefit to consumers. The droop coefficient is obtained by fuzzy logic controller of which the state of charge of the supercapacitor and unit-time electricity charge are assumed to be the input parameters. Simulation attest the feasibility of the proposed control coordination and energy management strategy.

14 January 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YTYe Tao
Ye Tao
QJQingquan Jia
Qingquan Jia
HDHaiyan Dong
Haiyan Dong
SXShiwei Xue
Shiwei Xue
LSLingling Sun
Lingling Sun
PLPan Li
Pan Li
In industries, AC contactors (ACCs) are sensitive to voltage sags. Most existing tolerance evaluation of ACC to voltage sags are based on rectangular sags, which tends to overestimation in practice. To tackle the evaluation problem facing irregular voltage sags, this letter presents a differential strategy based method for ACC. The instantaneous waveform of arbitrary voltage sags is split into the superposition of short-term step signal series in time domain. The relationships of differential energy variation inside ACC are modeled, and differential variation of spring compression is concluded. ACC responses to irregular voltage sags are formulated by superposition of short-term step responses. Simulations and experiments show that the proposed method is able to precisely evaluate the tolerance of ACC, settle the evaluation problem to irregular voltage sags.

1 March 2018 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
HYHao Yu
Hao Yu
QJQingquan Jia
Qingquan Jia
NWNing Wang
Ning Wang
HDHaiyan Dong
Haiyan Dong
This study introduces a data-driven modeling strategy for smart grid power quality (PQ) coupling assessment based on time series pattern matching to quantify the influence of single and integrated disturbance among nodes in different pollution patterns. Periodic and random PQ patterns are constructed by using multidimensional frequency-domain decomposition for all disturbances. A multidimensional piecewise linear representation based on local extreme points is proposed to extract the patterns features of single and integrated disturbance in consideration of disturbance variation trend and severity. A feature distance of pattern (FDP) is developed to implement pattern matching on univariate PQ time series (UPQTS) and multivariate PQ time series (MPQTS) to quantify the influence of single and integrated disturbance among nodes in the pollution patterns. Case studies on a 14-bus distribution system are performed and analyzed; the accuracy and applicability of the FDP in the smart grid PQ coupling assessment are verified by comparing with other time series pattern matching methods.

30 December 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JWJinlong Wang
Jinlong Wang
QJQingquan Jia
Qingquan Jia
LLLijuan Lin
Lijuan Lin
HDHaiyan Dong
Haiyan Dong
LXLicheng Xing
Licheng Xing
The escalating integration of distributed renewable energy into the grid has precipitated a decentralized and network-wide proliferation of harmonic sources. In urban distribution networks, the pronounced capacitive and distributed-parameter characteristics of cable lines exacerbate harmonic complexity, rendering them predisposed to multipoint local resonance. This study proposes a rigorous harmonic resonance suppression strategy for cabled distribution networks, grounded in global and local collaborative optimization. The global controller employs modal analysis to discern network-wide resonance modes, formulating a global admittance optimization reshaping model for weighted harmonic voltage to quell resonance across the entire network. Addressing dynamic changes in network parameters, a network division predicated on an event-triggered mechanism determines the local control scope for each suppression device. Ultimately, a localized dual-objective dynamic optimization adjustment model reshapes the virtual conductance of voltage-regulating active power filters and multifunctional grid-connected inverters in each region. Results attest to the efficacious suppression of harmonic resonance voltages to a qualified level, coupled with the successful resolution of parameter disturbances through local conductance adjustment.

1 January 2021 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
YWYunjing Wang
Yunjing Wang
AXAolan Xing
Aolan Xing
ZQZhengwei Qu
Zhengwei Qu
XHXiaoming Han
Xiaoming Han
HDHaiyan Dong
Haiyan Dong
PGPopov Maxim Georgievitch
Popov Maxim Georgievitch
With the continuous penetration of electric power information network and physical network, potential network attack threats have become increasingly prominent due to the inevitable security loopholes in the coupling and interaction of the two networks. In the energy management system (EMS), the state estimation module is the main target of hackers deliberately launching false data injection attacks (FDIAs) to the electric power. Starting from the redundancy of system measurement data, this paper proposes a pseudo-measurement modeling based on the CLSTM deep learning neural network; using interval numbers and affine numbers to reasonably analyze and quantitatively describe the measurement uncertainty, this paper proposes a FDIAs detection model based on interval affine state estimation. It provides technicians with the upper and lower limit information of the systems state, which makes it easier to judge whether the measured data is attacked and thus exceeds the normal fluctuation range. This paper has tested IEEE 33-bus system and the results show that this method has obvious advantages in term of calculation speed and accuracy.

2 July 2025 in Renewable Energy
Verified
Journal Article
Closed access
HDHaiyan Dong
Haiyan Dong
TZTie Zhang
Tie Zhang
ZCZhichang Chen
Zhichang Chen