Lueda Kulla

Lueda Kulla

Auto-generated profile, based on publicly available information

Lueda Kulla

Department of Chemistry Faculty of Natural Sciences University of Tirana Tiranë 1000 Albania

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2025 in ChemElectroChem
Verified
Journal Article
Open access
PJPetr Jakubec
Petr Jakubec
DPDavid Panáček
David Panáček
MNMartin‐Alex Nalepa
Martin‐Alex Nalepa
MRMarianna Rossetti
Marianna Rossetti
RÁRuslan Álvarez‐Diduk
Ruslan Álvarez‐Diduk
Michal OtyepkaMichal Otyepka
Michal Otyepka
This review highlights the role of graphene derivatives in advancing electrochemical biosensors for applications in diagnostics, environmental monitoring, and industrial sensing. Graphene derivatives, including graphene oxide (GO), reduced GO, and wide range of graphenes prepared via fluorographene chemistry, represent a prominent class of transducing materials in electrochemical biosensor development. Their ability to support covalent immobilization of biocomponents ensures stability, specificity, and long‐term performance, addressing limitations of noncovalent methods. Advances in fabrication, such as laser‐assisted reduction, enable scalable and cost‐effective production of conductive graphene‐based electrodes. Covalent functionalization techniques, like carbodiimide coupling and click chemistry, facilitate integration with bioreceptors, leading to highly selective biosensors. Emerging approaches, including inkjet printing of graphene‐based inks onto eco‐friendly substrates, promise sustainable and portable diagnostic devices. These advances support biosensors aligned with modern and sustainable technologies. Future efforts must focus on scalable production, improved multiplexing, and environmental sustainability to fully harness the potential of graphene derivatives in electrochemical biosensors.

25 September 2025 in Advanced Materials Technologies
Verified
Journal Article
Open access
MNMartin‐Alex Nalepa
Martin‐Alex Nalepa
LKLueda Kulla
Lueda Kulla
PJPetr Jakubec
Petr Jakubec
VHVítězslav Hrubý
Vítězslav Hrubý
DPDavid Panáček
David Panáček
Michal OtyepkaMichal Otyepka
Michal Otyepka
Nanomaterials are widely employed to enhance the performance of electrochemical sensors by modifying electrode surfaces. Traditionally, screen‐printed electrodes are manually coated with nanomaterial dispersions using the drop‐casting method, which suffers from poor reproducibility and limited reusability due to inconsistencies in deposition. This study introduces a novel electrochemical sensor based on nitrogen‐doped graphene acid (NGA), deposited via inkjet printing. This approach provides uniform, reproducible, and mechanically stable NGA coatings with significantly reduce material consumption (≈3 vs. ≈15 µg) compared to drop‐casting. The NGA‐modified electrodes exhibit enhanced electrochemical performance, as confirmed by a fourfold decrease in charge transfer resistance and a 2.5‐fold increase in current response. The sensor reliably detects imidacloprid, a common neonicotinoid pesticide, with excellent selectivity and long‐term stability exceeding 110 days. Inkjet printing enables precise material placement and layer control, ensuring strong adhesion and consistent performance even under mechanical stress and in complex matrices like tap water. This work demonstrates the potential of inkjet printing as a scalable and cost‐effective strategy for producing high‐performance electrochemical sensors.

20 January 2026 in Journal of Electrochemical Science and Engineering
Verified
Journal Article
Open access
PDF file
NBNevila Broli
Nevila Broli
SCSadik Cenolli
Sadik Cenolli
LVLoreta Vallja
Loreta Vallja
MVMajlinda Vasjari
Majlinda Vasjari
AAAna Ameda
Ana Ameda
LKLueda Kulla
Lueda Kulla
Atenolol, one of the most prescribed β₁-selective adrenergic blockers, has been increasingly detected in aquatic ecosystems due to incomplete elimination in sewage treatment plants, posing an ecotoxicological hazard to the environment. Here, an electrochemical sensor based on silver-decorated reduced graphene oxide composite carbon paste electrode (rGO@Ag-CPE) was designed for the ultrasensitive electroanalytical determination of atenolol in real-world samples. The morphology and chemical composition of rGO@Ag-CPE were investigated by trans­mission electron microscopy and energy-dispersive spectroscopy analyses, while the electro­chemical properties were evaluated by cyclic and square wave voltammetry techniques. The rGO@Ag-CPE demonstrated excellent electrocatalytic performance toward Atenolol oxidation, attributed to the unique properties of reduced graphene oxide and silver nanoparticles, which provide high conductivity and efficient electrocatalysis, thereby helping to prevent unwanted Atenolol degradation. Under optimized electrochemical sensing conditions, the rGO@Ag-CPE sensor exhibited a linear dynamic range of 20-859 μM (R² = 0.9953), a low detection limit of 2.9 μM, and good reproducibility (relative standard deviation < 4.0 %). A validation study on real-world samples showed good atenolol recovery of 88.8-102% in natural waters and 97-99.2 % in pharmaceutical tablets.

10 June 2025 in ChemElectroChem
Verified
Journal Article
Closed access
PJPetr Jakubec
Petr Jakubec
DPDavid Panáček
David Panáček
MNMartin‐Alex Nalepa
Martin‐Alex Nalepa
MRMarianna Rossetti
Marianna Rossetti
RÁRuslan Álvarez‐Diduk
Ruslan Álvarez‐Diduk
Michal OtyepkaMichal Otyepka
Michal Otyepka