Yi Zhang

Yi Zhang

Auto-generated profile, based on publicly available information

Yi Zhang

Nanjing Institute of Technology, Nanjing, PR China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2019 in IEEE Access
Verified
Journal Article
Open access
Zhijin ZhangZhijin Zhang
Zhijin Zhang
TLTian Liang
Tian Liang
JXJiang Xingliang
Jiang Xingliang
LCLi Chen
Li Chen
YSYang Shenghuan
Yang Shenghuan
ZYZhang Yi
Zhang Yi
In recent years, some composite insulators operating in coastal foggy areas have showed different levels degradation phenomena. This paper presents several performances and properties of silicone rubber under salt-fog environment with AC voltage. Analysis conducted after salt-fog treatment by techniques such as static contact angle, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), dielectric parameter and flashover voltage show a significant degradation of samples. The absorption peak of the hydrophobic groups (Si-(CH3)2 and Si-CH3) decreased, the surface of the material became rough, and the dielectric and electrical properties were also deteriorated. Due to the thermal effects and impact of high-energy particles, the molecular chains on the surface of silicone rubber were broken, and the smooth surface structure was destroyed, resulting in the formation of hydrophilic chemical bonds and precipitation of inorganic substances. The intrusion of moisture further reduces the dielectric parameters and the electrical strength of the material. In addition, the samples in the salt-fog environment with a greater conductivity are more degraded, indicating that the salt-fog has aggravating effect on the aging of the silicone rubber. Thus, it is recommended to pay attention to the monitoring and examining work of composite insulators operating in a foggy and high humidity environment.

30 December 2022 in High Voltage
Verified
Journal Article
Open access
YZYi Zhang
Yi Zhang
ZWZaijun Wu
Zaijun Wu
JHJiahong He
Jiahong He
DZDongdong Zhang
Dongdong Zhang
MHMinqiang Hu
Minqiang Hu
Long‐term thermal ageing might have impacts on the physicochemical properties of cross‐linked polyethene (XLPE) cables, thereby influencing their electrical behaviours, such as electrical treeing initiation and growth. The main objective of this work is to report the effects of thermal ageing on the electrical treeing behaviours (initiation and growth) in XLPE cable insulation. For this purpose, the electrical treeing initiation and growth test were performed in accelerated thermal samples. In addition, Differential Scanning Calorimetry and Fourier Transform Infrared Spectroscopy were utilised to investigate corresponding changes in the microstructures of materials. In addition, a correlation was established between electrical treeing behaviours and physicochemical properties during the thermal ageing process. Test results indicate that the thermal ageing process should be divided into three phases, and the re‐crystallisation reaction is considered the primary reason for the increase of average electrical tree initiation voltage (AETIV). Furthermore, the thermal ageing index X c is correlated to AETIV and the propagation rate of the electrical tree. As equivalent relationships have been established between the relative decrease value w of indexes AETIV, the propagating rate and X c , this method can be employed to predict the changing pattern of electrical treeing initiation voltage and the propagating rate in future research.

20 November 2019 in IEEE Access
Verified
Journal Article
Open access
YZYi Zhang
Yi Zhang
Zhijin ZhangZhijin Zhang
Zhijin Zhang
Xingliang JiangXingliang Jiang
Xingliang Jiang
TLTian Liang
Tian Liang
SYShenghuan Yang
Shenghuan Yang
In this paper, silicone rubber on composite insulators from three different manufacturers with an operating duration between 1 and 10 years were sampled. In order to investigate the law of diminishing performance of these samples in aging process, widely adopted aging process evaluation test methods such as Hydrophobicity test, Water absorption test were performed. Based on test results, parameters significantly correlated with operating time were obtained by means of correlation calculation. Finally, considering the differences of parameter values among three manufacturers, the relative decrease value (denoted as w) of parameters was proposed as a unified standard and the equivalent equations between w and operating time were established for predicting lifespan of composite insulators in high altitude area. Test results indicate that parameters including saturated water absorption ratio δs, the relative content of Si and O elements (XSi and XO) are significantly correlated with operating time, and these three parameters can be used to characterize aging degree of composite insulators. Besides, for the relative error σ1 between theoretical operating time calculated by the equivalent relationship obtained in this paper and actual operating time is less than 20%, within the allowable error range of engineering practice, this equation can be applied to predict the operating time of composite insulators from three manufacturers in future research.

4 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYi Zhang
Yi Zhang
ZWZaijun Wu
Zaijun Wu
CQChen Qian
Chen Qian
XTXiao Tan
Xiao Tan
JYJinggang Yang
Jinggang Yang
LZLinlin Zhong
Linlin Zhong
In this paper, cross-linked polyethylene (XLPE) cables of the same batch from Factory A, which ran from 1 to 8 years in Jiangsu Province, are sampled. Some widely accepted aging characterization methods of XLPE cables such as the gel content test, differential scanning calorimetry (DSC) test, tensile test and hardness test are employed to obtain the physicochemical, mechanical and electrical properties of the samples. Then, some lifespan prediction parameters significantly correlated with operating time are obtained through correlation calculations. Finally, a prediction method is proposed to predict the operating time of XLPE cables from Factory A. The test results indicate that parameters including the gel content Cge, the crystallinity XC, tensile strength σ, ultimate elongation δ, the dielectric permittivity ε, and the dielectric loss Jtan are significantly correlated with operating time, which can be used in evaluating the aging degree of XLPE cables. Moreover, due to the high accuracy of the experimental verification, it turns out that the lifespan prediction method proposed in this paper can be used to determine the operating time of XLPE cables from Factory A in future research.

2 October 2021 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
YZYi Zhang
Yi Zhang
ZWZaijun Wu
Zaijun Wu
JXJiajie Xu
Jiajie Xu
XTXiao Tan
Xiao Tan
DZDongdong Zhang
Dongdong Zhang
GLGang Liu
Gang Liu
Cross‐linked polyethylene (XLPE) cables are a critical component of power transmission systems. As operating conditions sometimes exceed the thresholds set in discipline, some cables fail to reach their designed lifespan, and consequently evaluating the aging degree of cables is particularly necessary. Here ten cables with an operating duration between 1 and 11 years from adjacent lines were sampled. Investigations were performed through various aging evaluation methods. Then typical lifespan prediction indices were concluded from test results and filtrated through correlation calculation. Meanwhile, a lifespan prediction method based on GM (1, N) model was proposed to establish the equivalent relationship between operating time and these indices. The research results indicated that, lifespan prediction indices obtained were all significantly correlated with operating time, which can be used to characterize aging degree of XLPE cables. Besides, due to the high prediction accuracy of experimental verification, the GM (1, N) model was proved to be applicable to evaluate the aging degree quantitatively and determine the remaining lifespan (relative to the designed lifespan) of XLPE cables. In future research, this method can be used to formulate a reasonable and economic withdrawal strategy for XLPE cables operating in conditions that exceed the thresholds set in the discipline.

26 June 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
YZYi Zhang
Yi Zhang
ZWZaijun Wu
Zaijun Wu
DZDongdong Zhang
Dongdong Zhang
JHJiahong He
Jiahong He
MGMaosen Guo
Maosen Guo
MHMinqiang Hu
Minqiang Hu
Long-term exposure to high temperatures can lead to the physicochemical properties of DC cross-linked polyethylene (XLPE) cable material degrading irreversibly, compromising its electrical performance. In this work, the effects of thermal aging on electrical tree initiation and the performance of treated cable material were examined. A Dam-flood model was constructed to investigate the effect of thermal aging on electrical tree initiation behaviors, where indices corresponding to aging performance and electrical tree initiation behaviors were obtained based on this model. Ultimately, by means of multiple linear regression estimation and a GM (1, N) model, prediction methods for the electrical tree initiation voltage ( U 50% ) and electrical tree initiation probability ( P ) were proposed. Results indicate that U 50% and P do not exhibit a monotonic change with an increase in thermal aging time and, based on the Dam-flood model, the recrystallization reaction can be regarded as the primary cause for this phenomenon. According to the Dam-flood model, the indices for gel content ( Cge ), crystallinity ( Xc ), and dielectric DC breakdown strength ( Eb ) are significantly correlated with U 50% , and these three indices can be used to determine the changing regularity of U 50% . Furthermore, as the relative errors of the validation samples are all less than 15%, an equivalent relationship between P and the indices corresponding to thermal aging performance can be established. This could be used in future research to determine the electrical tree initiation of XLPE cable.